SearcharxivSearch

arXiv subjects

Chuan Tan

Publications and source records attributed to Chuan Tan.

3 recordsLinked to original sources

MIASSR: An Approach for Medical Image Arbitrary Scale Super-Resolution

Single image super-resolution (SISR) aims to obtain a high-resolution output from one low-resolution image. Currently, deep learning-based SISR approaches have been widely discussed in medical image processing, because of their potential to achieve high-quality, high spatial resolution images without the cost of additional scans. However, most existing methods are designed for scale-specific SR tasks and are unable to generalise over magnification scales. In this paper, we propose an approach for medical image arbitrary-scale super-resolution (MIASSR), in which we couple meta-learning with generative adversarial networks (GANs) to super-resolve medical images at any scale of magnification in (1, 4]. Compared to state-of-the-art SISR algorithms on single-modal magnetic resonance (MR) brain images (OASIS-brains) and multi-modal MR brain images (BraTS), MIASSR achieves comparable fidelity performance and the best perceptual quality with the smallest model size. We also employ transfer learning to enable MIASSR to tackle SR tasks of new medical modalities, such as cardiac MR images (ACDC) and chest computed tomography images (COVID-CT). The source code of our work is also public. Thus, MIASSR has the potential to become a new foundational pre-/post-processing step in clinical image analysis tasks such as reconstruction, image quality enhancement, and segmentation.

eess.IV

Arbitrary Scale Super-Resolution for Brain MRI Images

Recent attempts at Super-Resolution for medical images used deep learning techniques such as Generative Adversarial Networks (GANs) to achieve perceptually realistic single image Super-Resolution. Yet, they are constrained by their inability to generalise to different scale factors. This involves high storage and energy costs as every integer scale factor involves a separate neural network. A recent paper has proposed a novel meta-learning technique that uses a Weight Prediction Network to enable Super-Resolution on arbitrary scale factors using only a single neural network. In this paper, we propose a new network that combines that technique with SRGAN, a state-of-the-art GAN-based architecture, to achieve arbitrary scale, high fidelity Super-Resolution for medical images. By using this network to perform arbitrary scale magnifications on images from the Multimodal Brain Tumor Segmentation Challenge (BraTS) dataset, we demonstrate that it is able to outperform traditional interpolation methods by up to 20$\%$ on SSIM scores whilst retaining generalisability on brain MRI images. We show that performance across scales is not compromised, and that it is able to achieve competitive results with other state-of-the-art methods such as EDSR whilst being fifty times smaller than them. Combining efficiency, performance, and generalisability, this can hopefully become a new foundation for tackling Super-Resolution on medical images. Check out the webapp here: https://metasrgan.herokuapp.com/ Check out the github tutorial here: https://github.com/pancakewaffles/metasrgan-tutorial

eess.IV

Generalized high-energy thermionic electron injection at graphene interface

Graphene thermionic electron emission across high-interface-barrier involves energetic electrons residing far away from the Dirac point where the Dirac cone approximation of the band structure breaks down. Here we construct a full-band model beyond the simple Dirac cone approximation for the thermionic injection of high-energy electrons in graphene. We show that the thermionic emission model based on the Dirac cone approximation is valid only in the graphene/semiconductor Schottky interface operating near room temperature, but breaks down in the cases involving high-energy electrons, such as graphene/vacuum interface or heterojunction in the presence of photon absorption, where the full-band model is required to account for the band structure nonlinearity at high electron energy. We identify a critical barrier height, $\Phi_B^{(\text{c})} \approx 3.5$ eV, beyond which the Dirac cone approximation crosses over from underestimation to overestimation. In the high-temperature thermionic emission regime at graphene/vacuum interface, the Dirac cone approximation severely overestimates the electrical and heat current densities by more than 50\% compared to the more accurate full-band model. The large discrepancies between the two models are demonstrated using a graphene-based thermionic cooler. These findings reveal the fallacy of Dirac cone approximation in the thermionic injection of high-energy electrons in graphene. The full-band model developed here can be readily generalized to other 2D materials, and shall provide an improved theoretical avenue for the accurate analysis, modeling and design of graphene-based thermionic energy devices.

cond-mat.mes-hall