SearcharxivSearch

arXiv subjects

Chun Yu Ma

Publications and source records attributed to Chun Yu Ma.

4 recordsLinked to original sources

Laser stabilized to a room temperature cavity with AlGaAs coatings reaching $4.2 \times 10^{-17}$ fractional frequency instability

We present a laser system referenced to a room-temperature ultrastable cavity employing crystalline AlGaAs coatings. We demonstrate a fractional frequency instability of $4.2 \times 10^{-17}$, which is one of the lowest for room temperature systems and surpasses the limit imposed by Brownian noise if dielectric coatings were employed. For the first time in a room temperature system we identified the spontaneous fluctuations of the coating birefringence as a leading contribution to frequency instability. At optimized conditions we achieve an ultrastable cavity with an eigenfrequency that is highly immune to power fluctuations. As acceleration noise is the main noise contribution, we demonstrated that a feed-forward method can reduce the influence of accelerations on the cavity-stabilized laser frequency by a factor of four.

physics.optics

Photo-birefringent effects in crystalline AlGaAs mirror coatings

High-reflective crystalline $GaAs/Al_{0.92}Ga_{0.08}As$ coatings show reduced Brownian noise compared to conventional dielectric coatings. However, several ultra stable laser systems observed additional noise sources that hinder the realization of the expected improvements in frequency stability. These additional noise sources are related to the birefringence of the coatings and its modification by intracavity light. The origin of the birefringence is not yet well understood and its modification via illumination remains unexplained. Here we present an extensive study on the steady-state and transient modification of the birefringence by intracavity light and by uniform illumination at various wavelengths using an optical cavity at room temperature. We find a unified description that suggests a primary two-photon process for photon energies below the bandgap of GaAs, or a single-photon process at higher energies. Adding external illumination allows to reduce noise induced by laser power fluctuations by balancing the photo-thermal-optic response of the mirrors and the photo-birefringent effect at a more favorable low intracavity power.

physics.optics

Guidelines for designs for ultrastable laser with $\mathbf{10^{-17}}$ fractional frequency instability

Lasers with long coherence time and narrow linewidth are an essential tool for quantum sensors and clocks. Ultrastable cavities and laser systems are now commercially available with fractional frequency instabilities in the mid $10^{-16}$ range. This document aims to provide technical guidance for researchers starting in the field of ultrastable lasers and to give an outlook toward the next generation of improved ultrastable lasers. These guidelines have arisen from the scope of the EMPIR project ``Next generation ultrastable lasers'' ( https://www.ptb.de/empir2021/nextlasers ) with contributions from the European project partners.

physics.optics

Excess noise and photo-induced effects in highly reflective crystalline mirror coatings

Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main contribution - Brownian thermal noise - is related to the mechanical loss of the coating material. Owing to their low mechanical losses, Al\textsubscript{0.92}Ga\textsubscript{0.08}As/GaAs crystalline mirror coatings are expected to reduce this limit. At room temperature they have demonstrated lower Brownian thermal noise than with conventional amorphous coatings. %However, no detailed study on the noise constituents from these coatings in optical interferometers has been conducted. We present a detailed study on the spatial and temporal noise properties of such coatings by using them in two independent cryogenic silicon optical Fabry-Perot resonators operated at 4 K, 16 K and 124 K. We confirm the expected low Brownian thermal noise, but also discover two new noise sources that exceed the Brownian noise: birefringent noise that can be canceled via polarization averaging and global excess noise (10 dB above Brownian noise). These new noise contributions are a barrier to improving ultra-stable lasers and the related performance of atomic clocks, and potentially limit the sensitivity of third-generation gravitational wave detectors. Hence, they must be considered carefully in precision interferometry experiments using similar coatings based on semiconductor materials.

physics.optics