SearcharxivSearch

arXiv subjects

Cian M Scannell

Publications and source records attributed to Cian M Scannell.

5 recordsLinked to original sources

Physics-Informed Implicit Neural Representations for Improved Myocardial Perfusion MRI Quantification

Quantifying myocardial perfusion from cardiac magnetic resonance (CMR) can be achieved by fitting tracer-kinetic models to the dynamic contrast-enhanced MR data. However, fitting the observed data with multi-compartment exchange models, which describe the evolution of the contrast agent in the tissue, to estimate perfusion parameters is a challenging inverse problem that is sensitive to noise and acquisition variability. Previously, physics-informed neural networks (PINNs) have been proposed as an alternative to conventional non-linear least squares fitting methods with promising results for quantitative perfusion CMR. In this work, we extend the previously proposed PINN framework with spatiotemporal implicit neural representations (INRs) to represent the MR signal as a continuous spatiotemporal function and to improve the accuracy, smoothness, and physical consistency of the PINN model. In realistic simulated CMR datasets, our proposed PINN with INRs demonstrates improved robustness and parameter estimation accuracy over the previously established methods. The code is available at https://github.com/q-cardIA/pinn-inr.

eess.IV

Foundation Models Adaptation for Multi-View Multi-modal Cardiac MRI Segmentation and Direct Ejection Fraction Estimation

Foundation models have shown strong transferability in cardiac MRI (CMR), but their effectiveness for heterogeneous multi-view and multi-sequence CMR analysis remains unclear. In this work, we explore the effectiveness of fine-tuning and combining different CMR foundation models for the Universal Multi-Sequence, Multi-Center and Multi-View CMR Segmentation (CMR-Multi) Challenge. CineMA was fine-tuned for cine and late gadolinium enhancement (LGE) segmentation across short-axis and long-axis views. For direct left-ventricular ejection fraction (LVEF) estimation, we used two recent frozen CMR foundation models to extract embedding vectors that were then combined using attention-based multiple-instance learning for LVEF regression. In the challenge validation set, cine segmentation achieved Dice scores of 0.862, 0.883, and 0.902 for short-axis, two-chamber and four-chamber cine MRI, respectively. LGE segmentation achieved Dice scores between 0.621 and 0.846 across views. The direct LVEF regression model achieved an MAE of 4.96 percentage points and a Pearson correlation of 0.91. These results indicate that foundation models can be effectively adapted and combined for multi-view CMR analysis, while accurate LGE scar segmentation remains a challenging task.

cs.CV

CardiSort: a convolutional neural network for cross vendor automated sorting of cardiac MR images

Objectives: To develop an image-based automatic deep learning method to classify cardiac MR images by sequence type and imaging plane for improved clinical post-processing efficiency. Methods: Multi-vendor cardiac MRI studies were retrospectively collected from 4 centres and 3 vendors. A two-head convolutional neural network ('CardiSort') was trained to classify 35 sequences by imaging sequence (n=17) and plane (n=10). Single vendor training (SVT) on single centre images (n=234 patients) and multi-vendor training (MVT) with multicentre images (n = 479 patients, 3 centres) was performed. Model accuracy was compared to manual ground truth labels by an expert radiologist on a hold-out test set for both SVT and MVT. External validation of MVT (MVTexternal) was performed on data from 3 previously unseen magnet systems from 2 vendors (n=80 patients). Results: High sequence and plane accuracies were observed for SVT (85.2% and 93.2% respectively), and MVT (96.5% and 98.1% respectively) on the hold-out test set. MVTexternal yielded sequence accuracy of 92.7% and plane accuracy of 93.0%. There was high accuracy for common sequences and conventional cardiac planes. Poor accuracy was observed for underrepresented classes and sequences where there was greater variability in acquisition parameters across centres, such as perfusion imaging. Conclusions: A deep learning network was developed on multivendor data to classify MRI studies into component sequences and planes, with external validation. With refinement, it has potential to improve workflow by enabling automated sequence selection, an important first step in completely automated post-processing pipelines.

eess.IV

Automated quantitative analysis of first-pass myocardial perfusion magnetic resonance imaging data

Coronary artery disease (CAD) remains the world's leading cause of mortality and the disease burden is continually expanding as the population ages. Recently, the MR-INFORM randomised trial has demonstrated that the management of patients with stable CAD can be guided by stress perfusion cardiovascular magnetic resonance (CMR) imaging and it is non-inferior to the using the invasive reference standard of fractional flow reserve. The benefits of using stress perfusion CMR include that it is non-invasive and significantly reduces the number of unnecessary coronary revascularisations. As compared to other ischaemia tests, it boasts a high spatial resolution and does not expose the patient to ionising radiation. However, the main limitation of stress perfusion CMR is that the diagnostic accuracy is highly dependent on the level of training of the operator, resulting in the test only being performed routinely in experienced tertiary centres. The clinical translation of stress perfusion CMR would be greatly aided by a fully automated, user-independent, quantitative evaluation of myocardial blood flow. This thesis presents major steps towards this goal: robust motion correction, automated image processing, reliable quantitative modelling, and thorough validation. The motion correction scheme makes use of data decomposition techniques, such as robust principal component analysis, to mitigate the difficulties in image registration caused by the dynamic contrast enhancement. The motion corrected image series are input to a processing pipeline which leverages the recent advances in image processing facilitated by deep learning. The pipeline utilises convolutional neural networks to perform a series of computer vision tasks including myocardial segmentation and right ventricular insertion point detection...

eess.IV

Automatic Myocardial Disease Prediction From Delayed-Enhancement Cardiac MRI and Clinical Information

Delayed-enhancement cardiac magnetic resonance (DE-CMR)provides important diagnostic and prognostic information on myocardial viability. The presence and extent of late gadolinium enhancement (LGE)in DE-CMR is negatively associated with the probability of improvement in left ventricular function after revascularization. Moreover, LGE findings can support the diagnosis of several other cardiomyopathies, but their absence does not rule them out, making disease classification by visual assessment difficult. In this work, we propose deep learning neural networks that can automatically predict myocardial disease from patient clinical information and DE-CMR. All the proposed networks achieve very good classification accuracy (>85%). Including information from DE-CMR (directly as images or as metadata following DE-CMR segmentation) is valuable in this classification task, improving the accuracy to 95-100%.

eess.IV