Searcharxiv⌕ Search

arXiv subjects

Clara Vergès

Publications and source records attributed to Clara Vergès.

6 recordsLinked to original sources

BICEP/Keck XXI: Constraints on Early-Universe Parity Violation from Multipole-Dependent Birefringence

We present the first constraints on multipole-dependent cosmic birefringence using CMB polarization data from the BK18 dataset, which combines observations from BICEP2, Keck Array, and BICEP3 at frequencies of 95, 150, and 220 GHz. Photon coupling to an axion-like field leads to the rotation of CMB polarization, inducing non-zero EB cross-correlations. We show that a multipole-dependent rotation beta(l) imprints a distinct signature in the polarization spectra that can be constrained. Specifically, we consider an Early Dark Energy (EDE) scenario in which a pseudoscalar field couples to photons through a Chern-Simons interaction, generating a polarization rotation with multipole dependence. We introduce a phenomenological beta(l) as a step function, obtaining constraints on the step function size consistent with zero, with uncertainties less than 0.15 degrees (68% CL). In addition, using multi-frequency EE, BB, and EB cross-spectra, along with robust BICEP/Keck foreground treatment and likelihood framework, we derive constraints on the axion-photon coupling amplitude g for several choices of EDE parameters. For the baseline best-fit value f_{EDE} = 0.087 from the Planck 2018 analysis, we obtain g = 0.11 +/- 0.37 (68% CL), consistent with previous limits.

astro-ph.CO↗

Calibration Measurements of the BICEP3 and BICEP Array CMB Polarimeters from 2017 to 2024

The BICEP3 and BICEP Array polarimeters are small-aperture refracting telescopes located at the South Pole designed to measure primordial gravitational wave signatures in the Cosmic Microwave Background (CMB) polarization, predicted by inflation. Constraining the inflationary signal requires not only excellent sensitivity, but also careful control of instrumental systematics. Both instruments use antenna-coupled orthogonally polarized detector pairs, and the polarized sky signal is reconstructed by taking the difference in each detector pair. As a result, the differential response between detectors within a pair becomes an important systematic effect we must control. Additionally, mapping the intensity and polarization response in regions away from the main beam can inform how sidelobe levels affect CMB measurements. Extensive calibration measurements are taken in situ every austral summer for control of instrumental systematics and instrument characterisation. In this work, we detail the set of beam calibration measurements that we conduct on the BICEP receivers, from deep measurements of main beam response to polarized beam response and sidelobe mapping. We discuss the impact of these measurements for instrumental systematics studies and design choices for future CMB receivers.

astro-ph.CO↗

Multi-layer anti-reflection coats using ePTFE membrane for mm-wavelength plastic optics

Future millimeter wavelength experiments aim to both increase aperture diameters and broaden bandwidths to increase the sensitivity of the receivers. These changes produce a challenging anti-reflection (AR) design problem for refracting and transmissive optics. The higher frequency plastic optics require consistently thin polymer coats across a wide area, while wider bandwidths require multilayer designs. We present multilayer AR coats for plastic optics of the high frequency BICEP Array receiver (200-300 GHz) utilizing an expanded polytetrafluoroethylene (ePTFE) membrane, layered and compressively heat-bonded to itself. This process allows for a range of densities (from 0.3g/cc to 1g/cc) and thicknesses (>0.05mm) over a wide radius (33cm), opening the parameter space of potential AR coats in interesting directions. The layered ePTFE membrane has been combined with other polymer layers to produce band average reflections between 0.2% and 0.6% on high density polyethylene and a thin high modulus polyethylene window, respectively.

astro-ph.IM↗

The Simons Observatory: gain, bandpass and polarization-angle calibration requirements for B-mode searches

We quantify the calibration requirements for systematic uncertainties for next-generation ground-based observatories targeting the large-angle $B$-mode polarization of the Cosmic Microwave Background, with a focus on the Simons Observatory (SO). We explore uncertainties on gain calibration, bandpass center frequencies, and polarization angles, including the frequency variation of the latter across the bandpass. We find that gain calibration and bandpass center frequencies must be known to percent levels or less to avoid biases on the tensor-to-scalar ratio $r$ on the order of $Δr\sim10^{-3}$, in line with previous findings. Polarization angles must be calibrated to the level of a few tenths of a degree, while their frequency variation between the edges of the band must be known to ${\cal O}(10)$ degrees. Given the tightness of these calibration requirements, we explore the level to which residual uncertainties on these systematics would affect the final constraints on $r$ if included in the data model and marginalized over. We find that the additional parameter freedom does not degrade the final constraints on $r$ significantly, broadening the error bar by ${\cal O}(10\%)$ at most. We validate these results by reanalyzing the latest publicly available data from the BICEP2/Keck collaboration within an extended parameter space covering both cosmological, foreground and systematic parameters. Finally, our results are discussed in light of the instrument design and calibration studies carried out within SO.

astro-ph.CO↗

Framework for analysis of next generation, polarised CMB data sets in the presence of galactic foregrounds and systematic effects

Reaching the sufficient sensitivity to detect primordial B-modes requires modern CMB polarisation experiments to rely on new technologies, necessary for the deployment of arrays thousands of detectors with a broad frequency coverage and operating them for extended periods of time. This increased complexity of experimental design unavoidably introduces new instrumental and systematic effects, which may impact performance of the new instruments. In this work we extend the standard data analysis pipeline by including a (parametric) model of instrumental effects directly in the data model. We then correct for them in the analysis, accounting for the additional uncertainty in the final results. We embed these techniques within a general, end-to-end formalism for estimating the impact of the instrument and foreground models on constraints on the amplitude of the primordial B-mode signal. We focus on the parametric component separation approach which we generalize to allow for simultaneous estimation of instrumental and foreground parameters. We demonstrate the framework by studying the effects induced by an achromatic half-wave plate (HWP), which lead to a frequency-dependent variation of the instrument polarisation angle, and experimental bandpasses which define observational frequency bands. We assume a typical Stage-3 CMB polarisation experiment, and show that maps recovered from raw data collected at each frequency band will unavoidably be linear mixtures of the Q and U Stokes parameters. We then derive a new generalized data model appropriate for such cases, and extend the component separation approach to account for it. We find that some of the instrumental parameters, in particularly those describing the HWP can be successfully constrained by the data themselves without need for external information, while others, like bandpasses, need to be known with good precision in advance.

astro-ph.CO↗

Studies of Systematic Uncertainties for Simons Observatory: Detector Array Effects

In this proceeding, we present studies of instrumental systematic effects for the Simons Obsevatory (SO) that are associated with the detector system and its interaction with the full SO experimental systems. SO will measure the Cosmic Microwave Background (CMB) temperature and polarization anisotropies over a wide range of angular scales in six bands with bandcenters spanning from 27 GHz to 270 GHz. We explore effects including intensity-to-polarization leakage due to coupling optics, bolometer nonlinearity, uncalibrated gain variations of bolometers, and readout crosstalk. We model the level of signal contamination, discuss proposed mitigation schemes, and present instrument requirements to inform the design of SO and future CMB projects.

astro-ph.IM↗