SearcharxivSearch

arXiv subjects

Clayton R. Locke

Publications and source records attributed to Clayton R. Locke.

5 recordsLinked to original sources

Spectroscopy and laser cooling on the $^{1}S_{0}-\,^{3}P_{1}$ line in Yb via an injection-locked diode laser at 1111.6nm

We generate 555.8nm light with sub-MHz linewidth through the use of laser injection-locking of a semiconductor diode at 1111.6nm, followed by frequency doubling in a resonant cavity. The integrity of the injection lock is investigated by studying an offset-beat signal between slave and master lasers, by performing spectroscopy on the $(6s)^{2}$ $^{1}S_{0}-\,(6s6p)$ $^{3}P_{1}$ transition in magneto-optically trapped ytterbium, and by demonstrating additional laser cooling of $^{171}$Yb with the 555.8nm light. For the $^{1}S_{0}-$ $^{3}P_{1}$ spectroscopy, we confirm the linear dependence between ground state linewidth and the intensity of an off-resonant laser, namely, that used to cool Yb atoms in a $^{1}S_{0}-$ $^{1}P_{1}$ magneto-optical trap. Our results demonstrate the suitability of injection locked 1100-1130nm laser diodes as a source for sub-MHz linewidth radiation in the yellow-green spectrum.

physics.optics

Laser frequency comb techniques for precise astronomical spectroscopy

Precise astronomical spectroscopic analyses routinely assume that individual pixels in charge-coupled devices (CCDs) have uniform sensitivity to photons. Intra-pixel sensitivity (IPS) variations may already cause small systematic errors in, for example, studies of extra-solar planets via stellar radial velocities and cosmological variability in fundamental constants via quasar spectroscopy, but future experiments requiring velocity precisions approaching ~1 cm/s will be more strongly affected. Laser frequency combs have been shown to provide highly precise wavelength calibration for astronomical spectrographs, but here we show that they can also be used to measure IPS variations in astronomical CCDs in situ. We successfully tested a laser frequency comb system on the Ultra-High Resolution Facility spectrograph at the Anglo-Australian Telescope. By modelling the 2-dimensional comb signal recorded in a single CCD exposure, we find that the average IPS deviates by <8 per cent if it is assumed to vary symmetrically about the pixel centre. We also demonstrate that series of comb exposures with absolutely known offsets between them can yield tighter constraints on symmetric IPS variations from ~100 pixels. We discuss measurement of asymmetric IPS variations and absolute wavelength calibration of astronomical spectrographs and CCDs using frequency combs.

astro-ph.IM

Improved test of Lorentz Invariance in Electrodynamics using Rotating Cryogenic Sapphire Oscillators

We present new results from our test of Lorentz invariance, which compares two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We have now acquired over 1 year of data, allowing us to avoid the short data set approximation (less than 1 year) that assumes no cancelation occurs between the $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters from the photon sector of the standard model extension. Thus, we are able to place independent limits on all eight $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters. Our results represents up to a factor of 10 improvement over previous non rotating measurements (which independently constrained 7 parameters), and is a slight improvement (except for $\tildeκ_{e-}^{ZZ}$) over results from previous rotating experiments that assumed the short data set approximation. Also, an analysis in the Robertson-Mansouri-Sexl framework allows us to place a new limit on the isotropy parameter $P_{MM}=δ-β+{1/2}$ of $9.4(8.1)\times10^{-11}$, an improvement of a factor of 2.

gr-qc

Rotating Resonator-Oscillator Experiments to Test Lorentz Invariance in Electrodynamics

In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an emphasis on rotating experiments in the laboratory. We compare the inherent sensitivity factors of common experiments and propose some new configurations. Finally we apply the test theories to the rotating cryogenic experiment at the University of Western Australia, which recently set new limits in both the RMS and SME frameworks [hep-ph/0506074].

hep-ph

Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic Sapphire Microwave Oscillators

We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on the previously unmeasured $\tildeκ_{e-}^{ZZ}$ component of $2.1(5.7)\times10^{-14}$, and set more stringent bounds by up to a factor of 7 on seven other components. In the RMS a more stringent bound of $-0.9(2.0)\times 10^{-10}$ on the isotropy parameter, $P_{MM}=δ- β+ {1/2}$ is set, which is more than a factor of 7 improvement. More detailed description of the experiment and calculations can be found in: hep-ph/0506200

hep-ph