SearcharxivSearch

arXiv subjects

Clifford Frez

Publications and source records attributed to Clifford Frez.

9 recordsLinked to original sources

TIME Commissioning Observations: II. On-sky Characterization and the 2D Map Data Processing Pipeline

The Tomographic Ionized-carbon Mapping Experiment (TIME) is a line intensity mapping (LIM) instrument that is designed to observe the power spectrum of the [CII] $158$~$\mu$m emission line during the Epoch of Reionization. TIME completed a commissioning run in 2022 at the Arizona Radio Observatory onboard the 12-M Radio Telescope at Kitt Peak, where it observed galactic sources for the first time. In this paper we report on an analysis of observations of the Orion Molecular Cloud (OMC) and G49.5 (a local HII region). The OMC observations were taken at least once a day to assess the stability of the instrument and demonstrate its on-sky performance. We describe a spectral image processing pipeline to make calibrated maps of raster scans of these sources, incorporating planet observations for gain calibration. We show with G49.5 that, when compared to the Bolocam Galactic Plane Survey, we are able to achieve a $< 3\%$ calibration difference. Based on the outcomes from this commissioning phase of TIME, we have demonstrated preliminary performance, and identified sources of improvement necessary for pursuing a LIM measurement.

astro-ph.IM

TIME Commissioning Observations: I. Mapping Dust and Molecular Gas in the Sgr A Molecular Cloud Complex at the Galactic Center

We present the processing of an observation of Sagittarius A (Sgr A) with the Tomographic Ionized-carbon Mapping Experiment (TIME), part of the 2021-2022 commissioning run to verify TIME's hyperspectral imaging capabilities for future line-intensity mapping. Using an observation of Jupiter to calibrate detector gains and pointing offsets, we process the Sgr A observation in a purpose-built pipeline that removes correlated noise through common-mode subtraction with correlation-weighted scaling, and uses map-domain principal component analysis to identify further systematic errors. The resulting frequency-resolved maps recover strong 12CO(2-1) and 13CO(2-1) emission, and a continuum component whose spectral index discriminates free-free emission in the circumnuclear disk (CND) versus thermal dust emission in the 20 km s$^{-1}$ and 50 km s$^{-1}$ molecular clouds. Broadband continuum flux comparisons with the Bolocam Galactic Plane Survey (BGPS) show agreement to within $\sim$5% in high-SNR molecular clouds in the Sgr A region. From the CO line detections, we estimate a molecular hydrogen mass of between $5.4 \times 10^5 M_\odot$ and $5.7 \times 10^5 M_\odot$, consistent with prior studies. These results demonstrate TIME's ability to recover both continuum and spectral-line signals in complex Galactic fields, validating its readiness for upcoming extragalactic CO and [C II] surveys.

astro-ph.IM

Development of a planar cable-driven parallel robot for submillimeter and terahertz beam mapping measurements

The spatial sensitivity pattern of millimeter-wavelength receivers is an important diagnostic of performance and is affected by the alignment of coupling optics. Characterization can be challenging in the field, particularly in the decentered and tightly packed optical configurations that are employed for many astronomical millimeter-wave cameras. In this paper, we present the design and performance of a lightweight and reconfigurable beam mapper, consisting of a bank of thermal sources positioned by a planar cable-driven robot. We describe how the measurement requirements and mechanical constraints of the Tomographic Ionized-carbon Mapping Experiment (TIME) optical relay drive the design of the mapper. To quantify the positioning performance, we predict the beam patterns at each surface to derive requirements and use a non-contact computer-vision based method built on OpenCV to track the payload position with an accuracy better than 1.0 mm. We achieve an in-plane absolute payload position error of 2.7 mm (RMSE) over a $\sim$400 mm $\times$ 400 mm workspace and an in-plane repeatability of 0.81 mm, offering substantial improvements in accuracy and speed over traditional handheld techniques.

astro-ph.IM

Battery-operated mid-infrared diode laser frequency combs

Mid-wave infrared (MIR, 3--5 $μ$m) optical frequency combs (OFC) are of critical importance for spectroscopy of fundamental molecular absorption features in space and terrestrial applications. Although in this band OFCs can be obtained via supercontinuum or difference frequency generation using optical pumping schemes, unprecedented source miniaturization and monolithic design are unique to electrically-pumped semiconductor laser structures. To date, high-brightness OFC generation in this region has been demonstrated in quantum- and interband cascade lasers (QCL/ICL), yet with sub-optimal spectral properties. Here, we show a MIR quantum well diode laser (QWDL) OFC, whose excellent spectral uniformity, narrow optical linewidths, and milliwatt optical power are obtained at a fraction of a watt of power consumption. The continuously tunable source offers ~1 THz of optical span centered at 3.04 $μ$m, and a repetition rate of 10 GHz. As a proof-of-principle, we show a directly-battery-operated MIR dual-comb source with almost 0.5 THz of optical coverage accessible in the electrical domain in microseconds. These results indicate the high suitability of QWDL OFCs for future chip-based real-time sensing systems in the mid-infrared.

physics.optics

Cavity-Enhanced Vernier Spectroscopy with a Chip-Scale Mid-Infrared Frequency Comb

Chip-scale optical frequency combs can provide broadband spectroscopy for diagnosing complex organic molecules. They are also promising as miniaturized laser spectrometers in applications ranging from atmospheric chemistry to geological science and the search for extraterrestrial life. While optical cavities are commonly used to boost sensitivity, it is challenging to realize a compact cavity-enhanced comb-based spectrometer. Here, we apply the Vernier technique to free-running operation of an interband cascade laser frequency comb in a simple linear geometry that performs cavity-enhanced chemical sensing. A centimeter-scale high-finesse cavity simultaneously provides selective mode filtering and enhancement of the path length to 30 meters. As a proof-of-concept, we sense transient open-path releases of ppm-level difluoroethane with 2 ms temporal resolution over a 1 THz optical bandwidth centered at 3.64 $μ$m.

physics.optics

Strong Negative Electrothermal Feedback in Thermal Kinetic Inductance Detectors

We demonstrate strong negative electrothermal feedback accelerating and linearizing the response of a thermal kinetic inductance detector (TKID). TKIDs are a proposed highly multiplexable replacement to transition-edge sensors and measure power through the temperature-dependent resonant frequency of a superconducting microresonator bolometer. At high readout probe power and probe frequency detuned from the TKID resonant frequency, we observe electrothermal feedback loop gain up to $\mathcal L$ $\approx$ 16 through measuring the reduction of settling time. We also show that the detector response has no detectable non-linearity over a 38% range of incident power and that the noise-equivalent power is below the design photon noise.

physics.ins-det

Probing Cosmic Reionization and Molecular Gas Growth with TIME

Line intensity mapping (LIM) provides a unique and powerful means to probe cosmic structures by measuring the aggregate line emission from all galaxies across redshift. The method is complementary to conventional galaxy redshift surveys that are object-based and demand exquisite point-source sensitivity. The Tomographic Ionized-carbon Mapping Experiment (TIME) will measure the star formation rate (SFR) during cosmic reionization by observing the redshifted [CII] 158$μ$m line ($6 \lesssim z \lesssim 9$) in the LIM regime. TIME will simultaneously study the abundance of molecular gas during the era of peak star formation by observing the rotational CO lines emitted by galaxies at $0.5 \lesssim z \lesssim 2$. We present the modeling framework that predicts the constraining power of TIME on a number of observables, including the line luminosity function, and the auto- and cross-correlation power spectra, including synergies with external galaxy tracers. Based on an optimized survey strategy and fiducial model parameters informed by existing observations, we forecast constraints on physical quantities relevant to reionization and galaxy evolution, such as the escape fraction of ionizing photons during reionization, the faint-end slope of the galaxy luminosity function at high redshift, and the cosmic molecular gas density at cosmic noon. We discuss how these constraints can advance our understanding of cosmological galaxy evolution at the two distinct cosmic epochs for TIME, starting in 2021, and how they could be improved in future phases of the experiment.

astro-ph.GA

Thermal Kinetic Inductance Detectors for millimeter-wave detection

Thermal Kinetic Inductance Detectors (TKIDs) combine the excellent noise performance of traditional bolometers with a radio frequency multiplexing architecture that enables the large detector counts needed for the next generation of millimeter-wave instruments. In this paper, we first discuss the expected noise sources in TKIDs and derive the limits where the phonon noise contribution dominates over the other detector noise terms: generation-recombination, amplifier, and two-level system (TLS) noise. Second, we characterize aluminum TKIDs in a dark environment. We present measurements of TKID resonators with quality factors of about $10^5$ at 80 mK. We also discuss the bolometer thermal conductance, heat capacity, and time constants. These were measured by the use of a resistor on the thermal island to excite the bolometers. These dark aluminum TKIDs demonstrate a noise equivalent power NEP = $2 \times 10^{-17} \mathrm{W}/\mathrm{\sqrt{Hz}} $, with a $1/f$ knee at 0.1 Hz, which provides background noise limited performance for ground-based telescopes observing at 150 GHz.

physics.ins-det

Mid-infrared dual-comb spectroscopy with low drive-power on-chip sources

Two semiconductor optical frequency combs consuming less than 1 W of electrical power are used to demonstrate high-sensitivity mid-infrared dual-comb spectroscopy in the important 3-4 $μ$m spectral region. The devices are 4 millimeters long by 4 microns wide, and each emits 8 mW of average optical power. The spectroscopic sensing performance is demonstrated by measurements of methane and hydrogen chloride with a spectral coverage of 33 cm$^{-1}$ (1 THz), 0.32 cm$^{-1}$ (9.7 GHz) frequency sampling interval, and peak signal-to-noise ratio of ~100 at 100 $μ$s integration time. The monolithic design, low drive power, and direct generation of mid-infrared radiation are highly attractive for portable broadband spectroscopic instrumentation in future terrestrial and space applications.

physics.ins-det