SearcharxivSearch

arXiv subjects

Clint Bockstiegel

Publications and source records attributed to Clint Bockstiegel.

11 recordsLinked to original sources

SCExAO/MEC and CHARIS Discovery of a Low Mass, 6 AU-Separation Companion to HIP 109427 using Stochastic Speckle Discrimination and High-Contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up $L_{\rm p}$ photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4-M5.5, 3000-3200 $K$, and $\log_{10}(L/L_{\rm \odot}) = -2.28^{+0.04}_{-0.04}$, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia-Hipparcos absolute astrometry of the primary favor a semimajor axis of $6.55^{+3.0}_{-0.48}$ au, an eccentricity of $0.54^{+0.28}_{-0.15}$, an inclination of $66.7^{+8.5}_{-14}$ degrees, and a dynamical mass of $0.280^{+0.18}_{-0.059}$ $M_{\odot}$. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely-used post-processing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

astro-ph.SR

The MKID Exoplanet Camera for Subaru SCExAO

We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument and is designed to operate both as an IFU, and as a focal plane wavefront sensor in a multi-kHz feedback loop with SCExAO. The read noise free, fast time domain information attainable by MKIDs allows for the direct probing of fast speckle fluctuations that currently limit the performance of most high contrast imaging systems on the ground and will help MEC achieve its ultimate goal of reaching contrasts of $10^{-7}$ at 2$λ/ D$. Here we outline the instrument details of MEC including the hardware, firmware, and data reduction and analysis pipeline. We then discuss MEC's current on-sky performance and end with future upgrades and plans.

astro-ph.IM

Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors

We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $μΩ$ cm with an RRR = 1.6. Resonators on the device displayed internal quality factors of around 200,000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process which resulted in pixels with decay times of about 40 $μ$s and resolving powers of ~9 at 800 nm.

astro-ph.IM

Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in the 2020s

Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.

astro-ph.IM

Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors

The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photons in the 800 to 1300 nm range, the amplifier increased the average resolving power of the detector from ~6.7 to 9.3 at which point the resolution becomes limited by noise on the pulse height of the signal. Noise measurements suggest that a resolving power of up to 25 is possible if redesigned detectors can remove this additional noise source.

astro-ph.IM

DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy

We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.

astro-ph.IM

Broadband parametric amplifiers based on nonlinear kinetic inductance artificial transmission lines

We present broadband parametric amplifiers based on the kinetic inductance of superconducting NbTiN thin films in an artificial (lumped-element) transmission line architecture. We demonstrate two amplifier designs implementing different phase matching techniques: periodic impedance loadings, and resonator phase shifters placed periodically along the transmission line. Our design offers several advantages over previous CPW-based amplifiers, including intrinsic 50 ohm characteristic impedance, natural suppression of higher pump harmonics, lower required pump power, and shorter total trace length. Experimental realizations of both versions of the amplifiers are demonstrated. With a transmission line length of 20 cm, we have achieved gains of 15 dB over several GHz of bandwidth.

quant-ph

Peculiar Velocity Constraints from Five-Band SZ Effect Measurements Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO

We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech Submillimeter Observatory with the Multiwavelength Submillimeter Inductance Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As part of our analysis, we have used higher frequency data from Herschel-SPIRE and previously published lower frequency radio data to subtract the signal from the brightest dusty star-forming galaxies behind RX J1347.5-1145 and from the AGN in RX J1347.5-1145's BCG. Using these five-band SZ effect images, combined with X-ray spectroscopic measurements of the temperature of the intra-cluster medium (ICM) from Chandra, we constrain the ICM optical depth to be $τ_e = 7.33^{+0.96}_{-0.97} \times 10^{-3}$ and the ICM line of sight peculiar velocity to be $v_{pec} = -1040^{+870}_{-840}$ km s$^{-1}$. The errors for both quantities are limited by measurement noise rather than calibration uncertainties or astrophysical contamination, and significant improvements are possible with deeper observations. Our best-fit velocity is in good agreement with one previously published SZ effect analysis and in mild tension with the other, although some or all of that tension may be because that measurement samples a much smaller cluster volume. Furthermore, our best-fit optical depth implies a gas mass slightly larger than the Chandra-derived value, implying the cluster is elongated along the line of sight.

astro-ph.CO

Frequency-tunable Superconducting Resonators via Nonlinear Kinetic Inductance

We have designed, fabricated and tested a frequency-tunable high-Q superconducting resonator made from a niobium titanium nitride film. The frequency tunability is achieved by injecting a DC current through a current-directing circuit into the nonlinear inductor whose kinetic inductance is current-dependent. We have demonstrated continuous tuning of the resonance frequency in a 180 MHz frequency range around 4.5 GHz while maintaining the high internal quality factor $Q_i> 180,000$. This device may serve as a tunable filter and find applications in superconducting quantum computing and measurement. It also provides a useful tool to study the nonlinear response of a superconductor. In addition, it may be developed into techniques for measurement of the complex impedance of a superconductor at its transition temperature and for readout of transition-edge sensors.

cond-mat.supr-con

Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray Imaging Spectroscopy

For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present our first working TKID prototypes which are able to achieve an energy resolution of 75 eV at 5.9 keV, even though their general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.

astro-ph.IM

Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera

We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own and nearby galaxies. MUSIC uses broadband superconducting phased-array slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to define spectral bands, and microwave kinetic inductance detectors to senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72 spatial pixels each. It is coupled to the telescope via an ambient temperature ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the image of the primary mirror formed by the ellipsoidal mirror. Dielectric and metal mesh filters are used to block thermal infrared and out-of-band radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates Earth's magnetic field. Each focal plane tile is read out by a single pair of coaxes and a HEMT amplifier. The readout system consists of 16 copies of custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We focus on recent updates on the instrument design and results from the commissioning of the full camera in 2012.

astro-ph.IM