Searcharxiv⌕ Search

arXiv subjects

Corinne E. Isaac

Publications and source records attributed to Corinne E. Isaac.

3 recordsLinked to original sources

mrfmsim: A modular, extendable, and readable simulation package for magnetic resonance force microscopy experiments

We present mrfmsim, an open-source Python package that facilitates the design, simulation, and analysis of magnetic resonance force microscopy (MRFM) experiments. MRFM is a scanning-probe technique that detects magnetic resonance from nanoscale ensembles of nuclear or electron spins with a force sensor. Because MRFM experiments are complex and operate at sensitivity limits, numerical simulation is essential for designing experiments and estimating per-spin sensitivity and imaging resolution from measured signals. In this paper, we highlight the challenges of developing MRFM simulations and show that software designed to simulate specific experiments only in a rapidly evolving experimental field can yield erroneous results. The mrfmsim package addresses these challenges by supporting post-definition customization without rewriting the internal model and by employing a plugin system for extending functionality. We show that the package's modular, extendable, and readable architecture improves reproducibility and accelerates development.

physics.comp-ph↗

Cryogenic positioning and alignment with micrometer precision

Aligning a microcantilever to an area of interest on a sample is a critical step in many scanning probe microscopy experiments, particularly those carried out on devices and rare, precious samples. We report a series of protocols that rapidly and reproducibly align a high-compliance microcantilever to a $< 10 \: μ\mathrm{m}$ sample feature under high vacuum and at cryogenic temperatures. The first set of protocols, applicable to a cantilever oscillating parallel to the sample surface, involve monitoring the cantilever resonance frequency while laterally scanning the tip to map the sample substrate through electrostatic interactions of the substrate with the cantilever. We demonstrate that when operating a cantilever a few micrometers from the sample surface, large shifts in the cantilever resonance frequency are present near the edges of a voltage-biased sample electrode. Surprisingly, these "edge-finder" frequency shifts are retained when the electrode is coated with a polymer film and a $\sim 10 \: \mathrm{nm}$ thick metallic ground plane. The second series of methods, applicable to any scanning probe microscopy experiment, integrate a single-optical fiber to image line scans of the sample surface. The microscope modifications required for these methods are straightforward to implement, provide reliable micrometer-scale positioning, and decrease the experimental setup time from days to hours in a vacuum, cryogenic magnetic resonance force microscope.

cond-mat.mes-hall↗

Dynamic nuclear polarization in a magnetic resonance force microscope experiment

We report achieving enhanced nuclear magnetization in a magnetic resonance force microscope experiment at 0.6 tesla and 4.2 kelvin using the dynamic nuclear polarization (DNP) effect. In our experiments a microwire coplanar waveguide delivered radiowaves to excite nuclear spins and microwaves to excite electron spins in a 250 nm thick nitroxide-doped polystyrene sample. Both electron and proton spin resonance were observed as a change in the mechanical resonance frequency of a nearby cantilever having a micron-scale nickel tip. NMR signal, not observable from Curie-law magnetization at 0.6 tesla, became observable when microwave irradiation was applied to saturate the electron spins. The resulting NMR signal's size, buildup time, dependence on microwave power, and dependence on irradiation frequency was consistent with a transfer of magnetization from electron spins to nuclear spins. Due to the presence of an inhomogenous magnetic field introduced by the cantilever's magnetic tip, the electron spins in the sample were saturated in a microwave-resonant slice 10's of nm thick. The spatial distribution of the nuclear polarization enhancement factor $ε$ was mapped by varying the frequency of the applied radiowaves. The observed enhancement factor was zero for spins in the center of the resonant slice, was $ε= +10$ to $+20$ for spins proximal to the magnet, and was $ε= -10$ to $-20$ for spins distal to the magnet. We show that this bipolar nuclear magnetization profile is consistent with cross-effect DNP in a $\sim \! 10^{5} \: \mathrm{T} \: \mathrm{m}^{-1}$ magnetic field gradient. Potential challenges associated with generating and using DNP-enhanced nuclear magnetization in a nanometer-resolution magnetic resonance imaging experiment are elucidated and discussed.

cond-mat.mes-hall↗