Searcharxiv⌕ Search

arXiv subjects

Cornelis A. T. van den Berg

Publications and source records attributed to Cornelis A. T. van den Berg.

26 records · Page 2Linked to original sources

Deep learning brain conductivity mapping using a patch-based 3D U-net

Purpose: To investigate deep learning electrical properties tomography (EPT) for application on different simulated and in-vivo datasets including pathologies for obtaining quantitative brain conductivity maps. Methods: 3D patch-based convolutional neural networks were trained to predict conductivity maps from B1 transceive phase data. To compare the performance of DLEPT networks on different datasets, three datasets were used throughout this work, one from simulations and two from in-vivo measurements from healthy volunteers and cancer patients, respectively. At first, networks trained on simulations are tested on all datasets with different levels of homogeneous Gaussian noise introduced in training and testing. Secondly, to investigate potential robustness towards systematical differences between simulated and measured phase maps, in-vivo data with conductivity labels from conventional EPT is used for training. Results: High quality of reconstructions from networks trained on simulations with and without noise confirms the potential of deep learning for EPT. However, artifact encumbered results in this work uncover challenges in application of DLEPT to in-vivo data. Training DLEPT networks on conductivity labels from conventional EPT improves quality of results. This is argued to be caused by robustness to artifacts from image acquisition. Conclusions: Networks trained on simulations with added homogeneous Gaussian noise yield reconstruction artifacts when applied to in-vivo data. Training with realistic phase data and conductivity labels from conventional EPT allows for severely reducing these artifacts.

physics.med-ph↗

Transceive Phase Corrected Contrast Source Inversion-Electrical Properties Tomography

Magnetic resonance imaging (MRI) based electrical properties tomography (EPT) is the quantification of the conductivity and permittivity of different tissues. These electrical properties can be obtained through different reconstruction methods and can be used as a contrast mechanism. The work presented here continues from the two-dimensional CSI-EPT algorithm which was shown to work with two-dimensional Matlab based simulations. The existing CSI-EPT algorithm is reformulated to use the transceive phase rather than relying on the transceive phase assumption. This is achieved by implementing a forward problem, computing the receive phase, into the inverse minimization problem, i.e. retrieving the electrical properties. Furthermore, the radio frequency (RF) shield is numerically implemented to model the RF fields inside the MRI more accurately. Afterwards, the algorithm is tested with three-dimensional FDTD simulations to investigate if the two-dimensional CSI-EPT can retrieve the electrical properties for three-dimensional RF fields. Finally, an MR experiment with a phantom is performed to show the potential for this method. From the results of the two-dimensional Matlab simulations it is seen that CSI-EPT can reconstruct the electrical properties using MRI accessible quantities. In the three-dimensional simulations it is observed that the electrical properties are underestimated, nonetheless, CSI-EPT is more precise than the standard Helmholtz based methods. Finally, the first CSI-EPT results using measured data are shown. The results for the reconstruction using measured data were of the same quality as the results from the FDTD simulation.

physics.med-ph↗

Model-based reconstruction of non-rigid 3D motion-fields from minimal $k$-space data: MR-MOTUS

Estimation of internal body motion with high spatio-temporal resolution can greatly benefit MR-guided radiotherapy/interventions and cardiac imaging, but remains a challenge to date. In image-based methods, where motion is indirectly estimated by reconstructing and co-registering images, a trade off between spatial and temporal resolution of the motion-fields has to be made due to the image reconstruction step. However, we observe that motion-fields are very compressible due to the spatial correlation of internal body motion. Therefore, reconstructing only motion-fields directly from surrogate signals or k-space data without the need for image reconstruction should require few data, and could eventually result in high spatio-temporal resolution motion-fields. In this work we introduce MR-MOTUS, a framework that makes exactly this possible. The two main innovations of this work are (1) a signal model that explicitly relates the k-space signal of a deforming object to general non-rigid motion-fields, and (2) model-based reconstruction of motion-fields directly from highly undersampled k-space data by solving the corresponding inverse problem. The signal model is derived by modeling a deforming object as a static reference object warped by dynamic motion-fields, such that the dynamic signal is given explicitly in terms of motion-fields. We validate the signal model through numerical experiments with an analytical phantom, and reconstruct motion-fields from retrospectively undersampled in-vivo data. Results show that the reconstruction quality is comparable to state-of-the-art image registration for undersampling factors as high as 63 for 3D non-rigid respiratory motion and as high as 474 for 3D rigid head motion.

physics.med-ph↗

Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy

To enable magnetic resonance (MR)-only radiotherapy and facilitate modelling of radiation attenuation in humans, synthetic-CT (sCT) images need to be generated. Considering the application of MR-guided radiotherapy and online adaptive replanning, sCT generation should occur within minutes. This work aims at assessing whether an existing deep learning network can rapidly generate sCT images to be used for accurate MR-based dose calculations in the entire pelvis. A study was conducted on data of 91 patients with prostate, rectal and cervical cancer who underwent external beam radiotherapy acquiring both CT and MRI for patients' simulation. Dixon reconstructed water, fat and in-phase images obtained from a conventional dual gradient-recalled echo sequence were used to generate sCT images. A conditional generative adversarial network (cGAN) was trained in a paired fashion on 2D transverse slices of 32 prostate cancer patients. The trained network was tested on the remaining patients to generate sCT images. For 30 patients in the test set, dose recalculations of the clinical plan were performed on sCT images. Dose distributions were evaluated comparing voxel-based dose differences, gamma and dose-volume histogram (DVH) analysis. The sCT generation required 5.6 s and 21 s for a single patient volume on a GPU and CPU, respectively. On average, sCT images resulted in a higher dose to the target of maximum 0.3%. Results suggest that accurate MR-based dose calculation using sCT images generated with a cGAN trained on prostate cancer patients is feasible for the entire pelvis. The sCT generation was sufficiently fast to be integrated into an MR-guided radiotherapy workflow.

physics.med-ph↗

Dictionary-free MR Fingerprinting reconstruction of balanced-GRE sequences

Magnetic resonance fingerprinting (MRF) can successfully recover quantitative multi-parametric maps of human tissue in a very short acquisition time. Due to their pseudo-random nature, the large spatial undersampling artifacts can be filtered out by an exhaustive search over a pre-computed dictionary of signal fingerprints. This reconstruction approach is robust to large data-model discrepancies and is easy to implement. The curse of dimensionality and the intrinsic rigidity of such a precomputed dictionary approach can however limit its practical applicability. In this work, a method is presented to reconstruct balanced gradient-echo (GRE) acquisitions with established iterative algorithms for nonlinear least-squares, thus bypassing the dictionary computation and the exhaustive search. The global convergence of the iterative approach is investigated by studying the transient dynamic response of balanced GRE sequences and its effect on the minimization landscape. Experimental design criteria are derived which enforce sensitivity to the parameters of interest and successful convergence. The method is validated on simulated and experimentally acquired MRI data. Keywords: MR Fingerprinting, quantitative MRI, Bloch equation, nonlinear least squares, sequence design.

physics.med-ph↗

Fast quantitative MRI as a nonlinear tomography problem

Quantitative Magnetic Resonance Imaging (MRI) is based on a two-steps approach: estimation of the magnetic moments distribution inside the body, followed by a voxel-by-voxel quantification of the human tissue properties. This splitting simplifies the computations but poses several constraints on the measurement process, limiting its efficiency. Here, we perform quantitative MRI as a one step process; signal localization and parameter quantification are simultaneously obtained by the solution of a large scale nonlinear inversion problem based on first-principles. As a consequence, the constraints on the measurement process can be relaxed and acquisition schemes that are time efficient and widely available in clinical MRI scanners can be employed. We show that the nonlinear tomography approach is applicable to MRI and returns human tissue maps from very short experiments. Keywords: MR-STAT, quantitative MRI, nonlinear tomography, MR Fingerprinting, large scale inversion.

physics.app-ph↗

Deep MR to CT Synthesis using Unpaired Data

MR-only radiotherapy treatment planning requires accurate MR-to-CT synthesis. Current deep learning methods for MR-to-CT synthesis depend on pairwise aligned MR and CT training images of the same patient. However, misalignment between paired images could lead to errors in synthesized CT images. To overcome this, we propose to train a generative adversarial network (GAN) with unpaired MR and CT images. A GAN consisting of two synthesis convolutional neural networks (CNNs) and two discriminator CNNs was trained with cycle consistency to transform 2D brain MR image slices into 2D brain CT image slices and vice versa. Brain MR and CT images of 24 patients were analyzed. A quantitative evaluation showed that the model was able to synthesize CT images that closely approximate reference CT images, and was able to outperform a GAN model trained with paired MR and CT images.

cs.CV↗

Element Decoupling of 7T Dipole Body Arrays by EBG Metasurface Structures: Experimental Verification

Metasurfaces are artificial electromagnetic boundaries or interfaces usually implemented as two-dimensional periodic structures with subwavelength periodicity and engineered properties of constituent unit cells. The electromagnetic bandgap (EBG) effect in metasurfaces prevents all surface modes from propagating in a certain frequency band. While metasurfaces provide a number of important applications in microwave antennas and antenna arrays, their features are also highly suitable for MRI applications. In this work we manufacture and experimentally study finite samples based on mushroom-type EBG metasurfaces and employ them for suppression of inter-element coupling in dipole transmit coil arrays for body imaging at 7T. We show experimentally that employment of the samples EBG leads to reduction of coupling between adjacent closely-spaced dipole antenna elements of a 7T transmit/receive body array, which reduces scattering losses in neighboring channels and thereby improves the B1+ efficiency. The setup consists of two fractionated dipole antennas previously designed by the authors for body imaging at 7 Tesla. These are placed on top of a body-mimicking phantom and equipped with the manufactured finite-size sample of the metasurface tuned to have EBG properties at the Larmor frequency of 298 MHz. To improve the detection range of the B1+ field distribution of the top elements, four additional elements were positioned along the bottom side of the phantom. Scattering matrix measurements show that coupling between the two top elements is indeed reduced while the measurements performed on a 7T MRI machine confirm the array's B1+ efficiency improvement due to reduced scattering losses. This study provides a tool for the decoupling of dipole antennas in ultrahigh field transmit arrays, possibly resulting in denser element placement and/or larger subject-element spacing.

physics.med-ph↗