Searcharxiv⌕ Search

arXiv subjects

Cristóbal Bertoglio

Publications and source records attributed to Cristóbal Bertoglio.

7 recordsLinked to original sources

Duct boundary conditions for incompressible fluid flows: finite element discretizations and parameter estimation in coronary blood flow

3D-0D coupled flow models are widely used across many application fields but remain challenging to solve. Implicit coupling introduces non-local terms, whereas explicit coupling results in only conditionally stable schemes. Furthermore, incorporating inertial effects alongside viscous resistance enlarges the parameter space, making calibration more difficult. In this work, we propose a new type of boundary condition based on the method of asymptotic partial decomposition of a domain (MAPDD), which we denote as the Duct Boundary Condition (DuBC). This approach enables the incorporation of geometrically reduced domains as a boundary term with only local coupling in the implicit case. Moreover, the DuBC accounts for both viscous and inertial effects simultaneously using a single physical parameter. Additionally, we derive a fractional-step time-marching scheme including the DuBC. We demonstrate the features of the DuBC in coronary artery blood flow simulations, including sequential parameter estimation from noisy velocity data.

math.NA↗

Optimal experimental design with k-space data: application to inverse hemodynamics

Subject-specific cardiovascular models rely on parameter estimation using measurements such as 4D Flow MRI data. However, acquiring high-resolution, high-fidelity functional flow data is costly and taxing for the patient. As a result, there is growing interest in using highly undersampled MRI data to reduce acquisition time and thus the cost, while maximizing the information gain from the data. Examples of such recent work include inverse problems to estimate boundary conditions of aortic blood flow from highly undersampled k-space data. The undersampled data is selected based on a predefined sampling mask which can significantly influences the performance and the quality of the solution of the inverse problem. While there are many established sampling patterns to collect undersampled data, it remains unclear how to select the best sampling pattern for a given set of inference parameters. In this paper we propose an Optimal Experimental Design (OED) framework for MRI measurements in k-space, aiming to find optimal masks for estimating specific parameters directly from k-space. As OED is typically applied to sensor placement problems in spatial locations, this is, to our knowledge, the first time the technique is used in this context. We demonstrate that the masks optimized by employing OED consistently outperform conventional sampling patterns in terms of parameter estimation accuracy and variance, facilitating a speed-up of 10x of the acquisition time while maintaining accuracy.

physics.med-ph↗

Fast generation of 3D flow obstacles from parametric surface models: application to cardiac valves

Due to the computationally demanding nature of fluid-structure interaction simulations, heart valve simulation is a complex task. A simpler alternative is to model the valve as a resistive flow obstacle that can be updated dynamically without altering the mesh, but this approach can also become computationally expensive for large meshes. In this work, we present a fast method for computing the resistive flow obstacle of a heart valve. The method is based on a parametric surface model of the valve, which is defined by a set of curves. The curves are adaptively sampled to create a polyline representation, which is then used to generate the surface. The surface is represented as a set of points, allowing for efficient distance calculations to determine whether mesh nodes belong to the valve surface. We introduce three algorithms for computing these distances: minimization, sampling, and triangulation. Additionally, we implement two mesh traversal strategies: exhaustive node iteration and recursive neighbor search. The latter significantly reduces the number of distance calculations by only considering neighboring nodes. Our pipeline is demonstrated on both a previously reported aortic valve model and a newly proposed mitral valve model, highlighting its flexibility and efficiency for rapid valve shape updates in computational simulations.

q-bio.TO↗

Parameter estimation in fluid flow models from undersampled frequency space data

4D Flow MRI is the state of the art technique for measuring blood flow, and it provides valuable information for inverse problems in the cardiovascular system. However, 4D Flow MRI has a very long acquisition time, straining healthcare resources and inconveniencing patients. Due to this, usually only a part of the frequency space is acquired, where then further assumptions need to be made in order to obtain an image. Inverse problems from 4D Flow MRI data have the potential to compute clinically relevant quantities without the need for invasive procedures, and/or expanding the set of biomarkers for a more accurate diagnosis. However, reconstructing MRI measurements with Compressed Sensing techniques introduces artifacts and inaccuracies, which can compromise the results of the inverse problems. Additionally, there is a high number of different sampling patterns available, and it is often unclear which of them is preferable. Here, we present a parameter estimation problem directly using highly undersampled frequency space measurements. This problem is numerically solved by a Reduced-Order Unscented Kalman Filter (ROUKF). We show that this results in more accurate parameter estimation for boundary conditions in a synthetic aortic blood flow than using measurements reconstructed with Compressed Sensing. We also compare different sampling patterns, demonstrating how the quality of the parameter estimation depends on the choice of the sampling pattern. The results show a considerably higher accuracy than an inverse problem using velocity measurements reconstructed via compressed sensing. Finally, we confirm these findings on real MRI data from a mechanical phantom.

math.NA↗

Automatic Mapping of Atrial Fiber Orientations for Patient-Specific Modeling of Cardiac Electromechanics using Image-Registration

Knowledge of appropriate local fiber architecture is necessary to simulate patient-specific electromechanics in the human heart. However, it is not yet possible to reliably measure in-vivo fiber directions, especially in human atria. Thus, we present a method which defines the fiber architecture in arbitrarily shaped atria using image registration and reorientation methods based on atlas atria with fibers predefined from detailed histological observations. Thereby, it is possible to generate detailed fiber families in every new patient-specific geometry in an automated, time-efficient process. We demonstrate the good performance of the image registration and fiber definition on ten differently shaped human atria. Additionally, we show that characteristics of the electrophysiological activation pattern which appear in the atlas atria also appear in the patients' atria. We arrive at analogous conclusions for coupled electro-mechano-hemodynamical computations.

physics.med-ph↗

Parametric model order reduction and its application to inverse analysis of large nonlinear coupled cardiac problems

Predictive high-fidelity finite element simulations of human cardiac mechanics co\-mmon\-ly require a large number of structural degrees of freedom. Additionally, these models are often coupled with lumped-parameter models of hemodynamics. High computational demands, however, slow down model calibration and therefore limit the use of cardiac simulations in clinical practice. As cardiac models rely on several patient-specific parameters, just one solution corresponding to one specific parameter set does not at all meet clinical demands. Moreover, while solving the nonlinear problem, 90\% of the computation time is spent solving linear systems of equations. We propose a novel approach to reduce only the structural dimension of the monolithically coupled structure-windkessel system by projection onto a lower-dimensional subspace. We obtain a good approximation of the displacement field as well as of key scalar cardiac outputs even with very few reduced degrees of freedom while achieving considerable speedups. For subspace generation, we use proper orthogonal decomposition of displacement snapshots. To incorporate changes in the parameter set into our reduced order model, we provide a comparison of subspace interpolation methods. We further show how projection-based model order reduction can be easily integrated into a gradient-based optimization and demonstrate its performance in a real-world multivariate inverse analysis scenario. Using the presented projection-based model order reduction approach can significantly speed up model personalization and could be used for many-query tasks in a clinical setting.

cs.CE↗

The importance of the pericardium for cardiac biomechanics: From physiology to computational modeling

The human heart is enclosed in the pericardial cavity. The pericardium consists of a layered thin sac and is separated from the myocardium by a thin film of fluid. It provides a fixture in space and frictionless sliding of the myocardium. The influence of the pericardium is essential for predictive mechanical simulations of the heart. However, there is no consensus on physiologically correct and computationally tractable pericardial boundary conditions. Here we propose to model the pericardial influence as a parallel spring and dashpot acting in normal direction to the epicardium. Using a four-chamber geometry, we compare a model with pericardial boundary conditions to a model with fixated apex. The influence of pericardial stiffness is demonstrated in a parametric study. Comparing simulation results to measurements from cine magnetic resonance imaging reveals that adding pericardial boundary conditions yields a better approximation with respect to atrioventricular plane displacement, atrial filling, and overall spatial approximation error. We demonstrate that this simple model of pericardial-myocardial interaction can correctly predict the pumping mechanisms of the heart as previously assessed in clinical studies. Utilizing a pericardial model can not only provide much more realistic cardiac mechanics simulations but also allows new insights into pericardial-myocardial interaction which cannot be assessed in clinical measurements yet.

cs.CE↗