SearcharxivSearch

arXiv subjects

D. Alesini

Publications and source records attributed to D. Alesini.

At least 19 recordsLinked to original sources

DA{\Phi}NE -2023/24 Activity report

The DA{\Phi}NE operations during the last year have been devoted to deliver a statistically significant data sample to perform the first-ever measurement of kaonic deuterium X-ray transitions to the fundamental level. Operations for the SIDDHARTA-2 detector using a deuterium gas target started officially on the second half of May 2023, and have been organized in several runs here described.

physics.acc-ph

Search for Axion dark matter with the QUAX-LNF tunable haloscope

We report the first experimental results obtained with the new haloscope of the QUAX experiment located at Laboratori Nazionali di Frascati of INFN (LNF). The haloscope is composed of a OFHC Cu resonant cavity cooled down to about 30 mK and immersed in a magnetic field of 8 T. The cavity frequency was varied in a 6 MHz range between 8.831496 and 8.83803 GHz. This corresponds to a previously unprobed mass range between 36.52413 and 36.5511 $\mu$eV. We don't observe any excess in the power spectrum and set limits on the axion-photon coupling in this mass range down to $g_{a\gamma\gamma} < 0.861 \times 10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.

physics.ins-det

TEX (TEst stand for X-band) at LNF

TEX facility if commissioned for high power testing to characterize accelerating structures and validate them for the operation on future particle accelerators for medical, industrial and research applications. At this aim, TEX is directly involved in the LNF leading project EuPRAXIA@SPARC_Lab. The brief description of the facility and its status and prospective will be provided.

physics.acc-ph

Search for galactic axions with a traveling wave parametric amplifier

A traveling wave parametric amplifier has been integrated in the haloscope of the QUAX experiment. A search for dark matter axions has been performed with a high Q dielectric cavity immersed in a 8 T magnetic field and read by a detection chain having a system noise temperature of about 2.1 K at the frequency of 10.353 GHz. Scanning has been conducted by varying the cavity frequency using sapphire rods immersed into the cavity. At multiple operating frequencies, the sensitivity of the instrument was at the level of viable axion models.

hep-ex

Design, optimization and experimental characterization of RF injectors for high brightness electron beams and plasma acceleration

In this article, we share our experience related to the new photo-injector commissioning at the SPARC\_LAB test facility. The new photo-injector was installed into an existing machine and our goal was not only to improve the final beam parameters themselves but to improve the machine handling in day-to-day operations as well. Thus, besides the pure beam characterization, this article contains information about the improvements, that were introduced into the new photo-injector design from the machine maintenance point of view, and the benefits, that we gained by using the new technique to assemble the gun itself.

physics.acc-ph

Search for galactic axions with a high-Q dielectric cavity

A haloscope of the QUAX--$aγ$ experiment, composed of an high-Q resonant cavity immersed in a 8 T magnet and cooled to $\sim 4.5$~K is operated to search for galactic axion with mass $m_a\simeq42.8~μ\text{eV}$. The design of the cavity with hollow dielectric cylinders concentrically inserted in a OFHC Cu cavity, allowed us to maintain a loaded quality-factor Q $\sim 300000$ during the measurements in presence of magnetic field. Through the cavity tuning mechanism it was possible to modulate the resonance frequency of the haloscope in the region $10.35337-10.35345$~GHz and thus acquire different dataset at different resonance frequencies. Acquiring each dataset for about 50 minutes, combining them and correcting for the axion's signal estimation-efficiency we set a limit on the axion-photon coupling $g_{aγγ}< 0.731\times10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.

hep-ex

A high-Q microwave dielectric resonator for axion dark matter haloscopes

The frequency band 1-15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high quality factor cavities that tolerate multi-Tesla fields plays a central role. We report a 3D resonator based on a right circular copper cavity with hollow cylinders that confine higher order modes around the cylinder axis. Its effective volume at 10.3\,GHz is $3.4 \cdot 10^{-2}$ liters, and under an 8\,T-field we measured an internal quality factor of more than 9 millions. These parameters demonstrate the potential of this unique resonator to probe galactic dark matter axion at remarkable scan rates of 15\,MHz/day when the cavity is readout by a quantum-limited receiver.

physics.ins-det

STAR HE-Linac Complete Detailed Design Report

This Document contains a complete technical description of the system devoted to the upgrade of the STAR Linear Accelerator (STAR Linac). According to the Contract signed between Universita della Calabria (UniCal) and Istituto Nazionale di Fisica Nucleare (INFN) on May 7th, 2021, INFN is committed to install, test and commission the upgrade of the STAR Linac denominated STAR-HE-Linac (STAR High Energy Linac), hereafter STAR-HEL. The technical components as well as the installation / test procedures and the ancillary equipment involved in such an upgrade are the object of this Document, named Complete Detailed Design Report. A technical offer was submitted by INFN in the frame of its participation to the tender issued by UniCal, describing a possible energy upgrade of the STAR Linac, with an electron beam energy boosted from 65 MeV up to 150 MeV by means of Radiofrequency (RF) accelerating sections and power stations based on S-band technology (ie, 2856 MHz RF frequency). Following the Contract signature, INFN conceived and conceptually designed a technology change that offers several advantages both on performances and on operational reliability of STAR-HEL, based on adopting C-band technology (ie, 5712 MHz RF frequency) for accelerating sections and RF power stations. Such a technology change was illustrated in a dedicated document named "improvement option for STAR-2 HE-Linac", addressed to UniCal STAR Management Board and tender R.U.P. for approval on June 9th, 2021. INFN received a formal letter of approval on June 16th, 2021.

physics.acc-ph

Search for invisible axion dark matter of mass m$_a=43~μ$eV with the QUAX--$aγ$ experiment

A haloscope of the QUAX--$aγ$ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to $\sim200$ mK is put in operation for the search of galactic axion with mass $m_a\simeq43~μ\text{eV}$. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With the data collected in about 1 h at the cavity frequency $ν_c=10.40176$ GHz, the experiment reaches the sensitivity necessary for the detection of galactic QCD-axion, setting the $90\%$ confidence level limit to the axion-photon coupling $g_{aγγ}<0.639\times10^{-13}$ GeV$^{-1}$.

hep-ex

International Workshop on Next Generation Gamma-Ray Source

A workshop on The Next Generation Gamma-Ray Sources sponsored by the Office of Nuclear Physics at the Department of Energy, was held November 17--19, 2016 in Bethesda, Maryland. The goals of the workshop were to identify basic and applied research opportunities at the frontiers of nuclear physics that would be made possible by the beam capabilities of an advanced laser Compton beam facility. To anchor the scientific vision to realistically achievable beam specifications using proven technologies, the workshop brought together experts in the fields of electron accelerators, lasers, and optics to examine the technical options for achieving the beam specifications required by the most compelling parts of the proposed research programs. An international assembly of participants included current and prospective $γ$-ray beam users, accelerator and light-source physicists, and federal agency program managers. Sessions were organized to foster interactions between the beam users and facility developers, allowing for information sharing and mutual feedback between the two groups. The workshop findings and recommendations are summarized in this whitepaper.

nucl-ex

Realization of a high quality factor resonator with hollow dielectric cylinders for axion searches

The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $\mbox{Q}_{300\mbox{K}}=(150,000\pm 2,000)$ and $\mbox{Q}_{4\mbox{K}}=(720,000\pm 10,000)$respectively, the latter corresponding to a gain of one order of magnitude with respect to a traditional copper cylindrical-cavity with the corresponding TM$_{010}$ mode resonating at the same frequency. The implications to dark-matter axion-searches with cavity experiments are discussed showing that the gain in quality factor is not spoiled by a reduced geometrical coupling $C_{030}$ of the cavity mode to the axion field. This reduction effect is estimated to be at most 20%. Numerical simulations show that frequency tuning of several hundreds MHz is feasible.

physics.ins-det

High quality factor photonic cavity for dark matter axion searches

Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magnetic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic structure by the use of sapphire rods. The quality factor at cryogenic temperature is in excess of $5 \times 10^5$ for a selected mode.

physics.ins-det

Axion search with a quantum-limited ferromagnetic haloscope

A ferromagnetic axion haloscope searches for Dark Matter in the form of axions by exploiting their interaction with electronic spins. It is composed of an axion-to-electromagnetic field transducer coupled to a sensitive rf detector. The former is a photon-magnon hybrid system, and the latter is based on a quantum-limited Josephson parametric amplifier. The hybrid system consists of ten 2.1 mm diameter YIG spheres coupled to a single microwave cavity mode by means of a static magnetic field. Our setup is the most sensitive rf spin-magnetometer ever realized. The minimum detectable field is $5.5\times10^{-19}\,$T with 9 h integration time, corresponding to a limit on the axion-electron coupling constant $g_{aee}\le1.7\times10^{-11}$ at 95% CL. The scientific run of our haloscope resulted in the best limit on DM-axions to electron coupling constant in a frequency span of about 120 MHz, corresponding to the axion mass range $42.4$-$43.1\,μ$eV. This is also the first apparatus to perform an axion mass scanning by changing the static magnetic field.

hep-ex

KLASH Conceptual Design Report

The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals that started a real race towards their discovery. This paper is the Conceptual Design Report of the KLASH (KLoe magnet for Axion SearcH) experiment at the Laboratori Nazionali di Frascati (LNF). The idea of this experiment has been stimulated by the availability of the large volume superconducting magnet, with a moderate magnetic field of 0.6 T, used in the KLOE detector at the DAFNE collider. The main conclusion we draw from this report is the possibility to build and put in operation at LNF in 2-3 years a large haloscope with the sensitivity to KSVZ axions in the low mass range between 0.2 and 1 $μ$eV, complementary to that of other experiments. Timeline and cost are competitive with respect to other proposals in the same mass region thanks to the availability of most of the infrastructure, in particular the superconducting magnet and the cryogenics plant.

physics.ins-det

Positron driven muon source for a muon collider

The design of a future multi-TeV muon collider needs new ideas to overcome the technological challenges related to muon production, cooling, accumulation and acceleration. In this paper a layout of a positron driven muon source known as the Low EMittance Muon Accelerator (LEMMA) concept is presented. The positron beam, stored in a ring with high energy acceptance and low emittance, is extracted and driven to a multi-target system, to produce muon pairs at threshold. This solution alleviates the issues related to the power deposited and the integrated Peak Energy Density Deposition (PEDD) on the targets. Muons produced in the multi-target system will then be accumulated before acceleration and injection in the collider. A multi-target line lattice has been designed to cope with the focusing of both the positron and muon beams. Studies on the number, material and thickness of the targets have been carried out. A general layout of the overall scheme and a description is presented, as well as plans for future R&D.

physics.acc-ph

Galactic axions search with a superconducting resonant cavity

To account for the dark matter content in our Universe, post-inflationary scenarios predict for the QCD axion a mass in the range $(10-10^3)\,μ\mbox{eV}$. Searches with haloscope experiments in this mass range require the monitoring of resonant cavity modes with frequency above 5\,GHz, where several experimental limitations occur due to linear amplifiers, small volumes, and low quality factors of Cu resonant cavities. In this paper we deal with the last issue, presenting the result of a search for galactic axions using a haloscope based on a $36\,\mbox{cm}^3$ NbTi superconducting cavity. The cavity worked at $T=4\,\mbox{K}$ in a 2\,T magnetic field and exhibited a quality factor $Q_0= 4.5\times10^5$ for the TM010 mode at 9\,GHz. With such values of $Q$ the axion signal is significantly increased with respect to copper cavity haloscopes. Operating this setup we set the limit $g_{aγγ}<1.03\times10^{-12}\,\mbox{GeV}^{-1}$ on the axion photon coupling for a mass of about 37\,$μ$eV. A comprehensive study of the NbTi cavity at different magnetic fields, temperatures, and frequencies is also presented.

physics.ins-det

The Klash Proposal: Status and Perspectives

Recently some of the authors proposed a search for galactic axions with mass about 0.2~$μ$eV using a large volume resonant cavity, tens of cubic meters, cooled down to 4~K and immersed in a magnetic field of about 0.6~T generated inside the superconducting magnet of the KLOE experiment located at the National Laboratory of Frascati of INFN. This experiment, called KLASH (KLoe magnet for Axion SearcH), has a potential sensitivity on the axion-to-photon coupling, $g_{aγγ}$, of about $6\times10^{-17}$ $\mbox{GeV}^{-1}$, reaching the region predicted by KSVZ\cite{KSVZ} and DFSZ\cite{DFSZ} models of QCD axions. We report here the status of the project.

physics.ins-det

Operation of a ferromagnetic axion haloscope at $m_a=58\,μ$eV

Axions, originally proposed to solve the strong CP problem of quantum chromodynamics, emerge now as leading candidates of WISP dark matter. The rich phenomenology associated to the light and stable QCD axion can be described as an effective magnetic field that can be experimentally investigated. For the QUAX experiment, dark matter axions are searched by means of their resonant interactions with electronic spins in a magnetized sample. In principle, axion-induced magnetization changes can be detected by embedding a sample in an rf cavity in a static magnetic field. In this work we describe the operation of a prototype ferromagnetic haloscope, with a sensitivity limited by thermal fluctuations and receiver noise. With a preliminary dark matter search, we are able to set an upper limit on the coupling constant of DFSZ axions to electrons $g_{aee}<4.9\times10^{-10}$ at 95\% C.L. for a mass of $58\,μ$eV (i.\,e. 14\,GHz). This is the first experimental result with an apparatus exploiting the coupling between cosmological axions and electrons.

hep-ex