SearcharxivSearch

arXiv subjects

D. Attie

Publications and source records attributed to D. Attie.

18 recordsLinked to original sources

The ILD Detector: A Versatile Detector for an Electron-Positron Collider at Energies up to 1 TeV

The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magnetic field. The paradigm of particle flow has been the guiding principle of the design of ILD. ILD is based mostly on technologies which have been demonstrated by extensive research and test programs. The ILD concept is proposed both for linear and circular lepton collider, be it at CERN or elsewhere. The concept has been developed by a group of nearly 60 institutes from around the world, and offers a well developed and powerful environment for science and technology studies at lepton colliders. In this document, the required performance of the detector, the proposed implementation and the readiness of the different technologies needed for the implementation are discussed.

hep-ex

A Linear Collider Vision for the Future of Particle Physics

In this paper we review the physics opportunities at linear $e^+e^-$ colliders with a special focus on high centre-of-mass energies and beam polarisation, take a fresh look at the various accelerator technologies available or under development and, for the first time, discuss how a facility first equipped with a technology mature today could be upgraded with technologies of tomorrow to reach much higher energies and/or luminosities. In addition, we will discuss detectors and alternative collider modes, as well as opportunities for beyond-collider experiments and R\&D facilities as part of a linear collider facility (LCF). The material of this paper will support all plans for $e^+e^-$ linear colliders and additional opportunities they offer, independently of technology choice or proposed site, as well as R\&D for advanced accelerator technologies. This joint perspective on the physics goals, early technologies and upgrade strategies has been developed by the LCVision team based on an initial discussion at LCWS2024 in Tokyo and a follow-up at the LCVision Community Event at CERN in January 2025. It heavily builds on decades of achievements of the global linear collider community, in particular in the context of CLIC and ILC.

hep-ex

Characterization of Charge Spreading and Gain of Encapsulated Resistive Micromegas Detectors for the Upgrade of the T2K Near Detector Time Projection Chambers

An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and reliable operation of the detectors once installed. A dedicated X-ray test bench is used to characterize the detectors by scanning each pad individually and to precisely measure the uniformity of the gain and the deposited energy resolution over the pad plane. An energy resolution of about 10% is obtained. A detailed physical model has been developed to describe the charge dispersion phenomena in the resistive Micromegas anode. The detailed physical description includes initial ionization, electron drift, diffusion effects and the readout electronics effects. The model provides an excellent characterization of the charge spreading of the experimental measurements and allowed the simultaneous extraction of gain and RC information of the modules.

physics.ins-det

Performances of a resistive MicroMegas module for the Time Projection Chambers of the T2K Near Detector upgrade

An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas amplification. A first prototype of resistive MicroMegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CERN. The data have been used to characterize the performances of the resistive MicroMegas module. A spatial resolution of 300 $μm$ and a deposited energy resolution of 9% were observed for horizontal electrons crossing the TPCs at 30 cm from the anode. Such performances fully satisfy the requirements for the upgrade of the ND280 TPC.

physics.ins-det

Physics potential of the International Axion Observatory (IAXO)

We review the physics potential of a next generation search for solar axions: the International Axion Observatory (IAXO). Endowed with a sensitivity to discover axion-like particles (ALPs) with a coupling to photons as small as $g_{aγ}\sim 10^{-12}$ GeV$^{-1}$, or to electrons $g_{ae}\sim$10$^{-13}$, IAXO has the potential to find the QCD axion in the 1 meV$\sim$1 eV mass range where it solves the strong CP problem, can account for the cold dark matter of the Universe and be responsible for the anomalous cooling observed in a number of stellar systems. At the same time, IAXO will have enough sensitivity to detect lower mass axions invoked to explain: 1) the origin of the anomalous "transparency" of the Universe to gamma-rays, 2) the observed soft X-ray excess from galaxy clusters or 3) some inflationary models. In addition, we review string theory axions with parameters accessible by IAXO and discuss their potential role in cosmology as Dark Matter and Dark Radiation as well as their connections to the above mentioned conundrums.

hep-ph

LEETECH facility as a flexible source of low energy electrons

A new versatile facility LEETECH for detector R&D, tests and calibration is designed and constructed. It uses electrons produced by the photoinjector PHIL at LAL, Orsay and provides a powerful tool for wide range R&D studies of different detector concepts delivering "mono-chromatic" samples of low energy electrons with adjustable energy and intensity. Among other innovative instrumentation techniques, LEETECH will be used for testing various gaseous tracking detectors and studying new Micromegas/InGrid concept which has very promising characteristics of spatial resolution and can be a good candidate for particle tracking and identification. In this paper the importance and expected characteristics of such facility based on detailed simulation studies are addressed.

physics.ins-det

Ageing studies of resistive Micromegas detectors for the HL-LHC

Resistive-anode Micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working in high flux and high radiations environment like in the HL-LHC (ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to assess their capabilities to handle the HL-LHC environment on a long-term period. A prototype has been exposed to several types of irradiations (X-rays, cold neutrons, 60 Co gammas) up to an equivalent HL-LHC time of more than five years without showing any degradation of the performances in terms of gain and energy resolution. Beam test studies took place in October 2012 to assess the tracking performances (efficiency, spatial resolution,...). Results of ageing studies and beam test performances are reported in this paper.

physics.ins-det

Characterization and simulation of resistive-MPGDs with resistive strip and layer topologies

The use of resistive technologies to MPGD detectors is taking advantage for many new applications, including high rate and energetic particle flux scenarios. The recent use of these technologies in large area detectors makes necessary to understand and characterize the response of this type of detectors in order to optimize or constrain the parameters used in its production, material resistivity, strip width, or layer thickness. The values to be chosen will depend on the environmental conditions in which the detector will be placed, and the requirements in time resolution and gain, improving the detector performance for each given application. We present two different methods to calculate the propagation of charge diffusion through different resistive topologies; one is based on a FEM of solving the telegraph equation in our particular strip detector scheme, the other is based on a semi-analytical approach of charge diffusion and is used to determine the charge evolution in a resistive layer.

physics.ins-det

A Piggyback resistive Micromegas

A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant loss, signals are transmitted by capacitive coupling to the read-out pads. The detector provides high gas gain, good energy resolution and the resistive layer assures spark protection to the electronics. This assembly could be combined with modern pixel array electronic ASICs. This readout organization is free on how the pixels are designed, arranged and connected. We present first results taken with a MediPix read-out chip.

physics.ins-det

Performances of Anode-resistive Micromegas for HL-LHC

Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-out strip pitches. These chambers were tested using \sim120 GeV momentum pions, at H6 CERN-SPS beam line in autumn 2010. For a strip pitch 500 micrometers we measure a resolution of \sim90 micrometers and a efficiency of ~98%. The track angle effect on the efficiency was also studied. Our results show that resistive techniques induce no degradation on the efficiency or resolution, with respect to the standard Micromegas. In some configuration the resistive coating is able to reduce the discharge currents at least by a factor of 100.Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-out strip pitches. These chambers were tested using \sim120 GeV momentum pions, at H6 CERN-SPS beam line in autumn 2010. For a strip pitch 500 micrometers we measure a resolution of \sim90 micrometers and a efficiency of \sim98%. The track angle effect on the efficiency was also studied. Our results show that resistive techniques induce no degradation on the efficiency or resolution, with respect to the standard Micromegas. In some configuration the resistive coating is able to reduce the discharge currents at least by a factor of 100.

physics.ins-det

Aging studies of Micromegas prototypes for the HL-LHC

The micromegas technology is a promising candidate to replace the forward muon chambers for the luminosity upgrade of ATLAS. The LHC accelerator luminosity will be five times the nominal one, increasing background and pile-up event probability. This requires detector performances which are currently under study in intensive R&D activities. Aging is one of the key issues for a high-luminosity LHC application. For this reason, we study the properties of resistive micromegas detectors under intense X-ray radiation and under thermal neutrons in different CEA-Saclay facilities. This study is complementary to those already performed using fast neutrons.

physics.ins-det

MICROMEGAS chambers for hadronic calorimetry at a future linear collider

Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and pressure correction of data is presented. A stack of four chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams respectively. Measurements of response uniformity, detection efficiency and hit multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital readout electronics has been assembled and tested. The chamber layout and first results are presented.

physics.ins-det

Micromegas TPC studies at high magnetic fields using the charge dispersion signal

The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The new MPGD readout technique of charge dispersion can achieve good resolution without resorting to narrow pads. This has been demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a Micromegas-TPC using the charge dispersion readout concept in a high field super-conducting magnet at DESY. The measured Micromegas gain was found to be constant within 0.5% for magnetic fields up to 5 Tesla. With the strong suppression of transverse diffusion at high magnetic fields, we measure a flat 50 micron resolution at 5 Tesla over the full 15 cm drift length of our prototype TPC.

physics.ins-det

Search for 44Ti gamma-ray line emission from GRO J0852-4642 with INTEGRAL/SPI

The gamma-ray source GRO J0852-4642, discovered by COMPTEL, is a possible counterpart of the supernova remnant RX J0852-4622. Detection of radioactive decay from 44Ti nuclei would proof it to be the youngest and nearest supernova remnant known so far. During the first year of INTEGRAL core program, the Vela region was observed twice in all for more than 2000 ks. Among other nucleosynthesis studies, one of the most important scientific goals of this observation is the detection of 44Ti gamma-ray lines expected at 68 keV, 78 keV and 1157 keV. For this purpose the INTEGRAL Spectrometer (SPI), with its very high energy resolution thanks to its germanium detector camera is the key instrument, permitting a precise determination of gamma-ray line intensities and profiles. The upper limit for the 78.4 keV 44Ti gamma-ray line emission derived from the first analysis is 1.1 x 10^{-4} gamma/cm2s. This value is mainly dominated by systematic uncertainties in the treatment of the instrumental background. By accumulating more observation time in the next years of the mission and by improving the background understanding, a reliable 44Ti flux for GRO J0852-4642 or an upper limit which constrains the COMPTEL flux can be expected.

astro-ph

INTEGRAL broadband spectroscopy of Vela X-1

The wind-accreting X-ray binary pulsar and cyclotron line source Vela X-1 has been observed extensively during INTEGRAL Core Program observations of the Vela region in June-July and November-December 2003. In the latter set of observations the source showed intense flaring -- see also Staubert et al. (2004), these proceedings. We present early results on time averaged and time resolved spectra, of both epochs of observations. A cyclotron line feature at ~53 keV is clearly detected in the INTEGRAL spectra and its broad shape is resolved in SPI spectra. The remaining issues in the calibration of the instruments do not allow to resolve the question of the disputed line feature at 20-25 keV. During the first main flare the average luminosity increases by a factor of \~10, but the spectral shape remains very similar, except for a moderate softening.

astro-ph

The INTEGRAL/SPI response and the Crab observations

The Crab region was observed several times by INTEGRAL for calibration purposes. This paper aims at underlining the systematic interactions between (i) observations of this reference source, (ii) in-flight calibration of the instrumental response and (iii) the development and validation of the analysis tools of the SPI spectrometer. It first describes the way the response is produced and how studies of the Crab spectrum lead to improvements and corrections in the initial response. Then, we present the tools which were developed to extract spectra from the SPI observation data and finally a Crab spectrum obtained with one of these methods, to show the agreement with previous experiments. We conclude with the work still ahead to understand residual uncertainties in the response.

astro-ph

Search for a light dark matter annihilation signal in the Sagittarius Dwarf Galaxy

The 511 keV emission from the Galactic Bulge observed by INTEGRAL/SPI could be the product of light (1-100 MeV) annihilating dark matter particles. In order to distinguish between annihilating light dark matter scenarios and more conventional astrophysical sources for the bulge emission, we propose to test the light dark matter hypothesis on the Sagittarius Dwarf Galaxy, a close-by galaxy dominated by dark matter. The predicted flux being in the SPI sensitivity range, the detection of a substantial 511 keV emission line from this galaxy would provide a strong evidence for the light dark matter hypothesis. During the two Galactic Center Deep Exposures performed in 2003, the Sagittarius Dwarf Galaxy was in the field of view of several INTEGRAL observations. In this paper we present preliminary results of the analysis of these data.

astro-ph

New determinations of gamma-ray line intensities of the Ep = 550 keV and Ep = 1747 keV resonances of the 13-C(p,gamma)14-N reaction

Gamma-ray angular distributions for the resonances at Ep = 550 keV and 1747 keV of the radiative capture reaction 13-C(p,g)14-N have been measured, using intense proton beams on isotopically pure 13-C targets. Relative intensities for the strongest transitions were extracted with an accuracy of typically five per cent, making these resonances new useful gamma-ray standards for efficiency calibration in the energy range Egamma = 1.6 to 9 MeV.

nucl-ex