SearcharxivSearch

arXiv subjects

D. B. Tanner

Publications and source records attributed to D. B. Tanner.

At least 19 recordsLinked to original sources

Axion Dark Matter eXperiment around 3.3 μeV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability

We report the results of a QCD axion dark matter search with discovery ability for Dine Fischler Srednicki Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultra low-noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 $μ$eV, assuming a standard halo model with a local energy density of 0.45 GeV/cm$^3$ made up 100% of axions.

hep-ex

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong CP problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10-1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov (KSVZ) sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.

hep-ex

Improved Receiver Noise Calibration for ADMX Axion Search: 4.54 to 5.41 $μ$eV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra low-noise electronics. In this paper we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280~MHz taken during ADMX's most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and JPA, as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

hep-ex

Search for non-virialized axions with 3.3-4.2 $μ$eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of $ρ_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ and $ρ_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range $3.3-4.2\,μ\text{eV}$. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

astro-ph.CO

Design and Performance of the ALPS II Regeneration Cavity

The Regeneration Cavity (RC) is a critical component of the Any Light Particle Search II (ALPS II) experiment. It increases the signal from possible axions and axion-like particles in the experiment by nearly four orders of magnitude. The total round-trip optical losses of the power circulating in the cavity must be minimized in order to maximize the resonant enhancement of the cavity, which is an important figure of merit for ALPS II. Lower optical losses also increase the cavity storage time and with the 123 meter long ALPS II RC we have demonstrated the longest storage time of a two-mirror optical cavity. We measured a storage time of $7.17 \pm 0.01$ ms, equivalent to a linewidth of 44.4 Hz and a finesse of 27,500 at a wavelength of 1064 nm.

physics.optics

Identification of Resonant Frequencies in LIGO-like Suspension with Finite-Element Modeling

Following the upgrades to Advanced LIGO (aLIGO), measurements were made of the detector suspensions' frequency response characteristics. While most resonant frequencies could be identified with simple mechanical models, such as the fiber vibration modes, some were unexplained. Using a finite element model of the quadruple pendulum suspension, we search for and identify lines from unknown sources. The present work focuses on two resonant lines observed in the Upper Intermediate Mass as examples of this technique. Our simulations suggest a common source for these lines, which could be accounted for in a redesign. By modeling these response frequencies, we can examine the motion of individual components, and suggest methods to reduce their amplitude, alter their frequency, or eliminate them in future gravitational wave detector designs.

gr-qc

Axion Dark Matter eXperiment: Run 1A Analysis Details

The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.

hep-ex

Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.

astro-ph.CO

Search for a dark-matter induced Cosmic Axion Background with ADMX

We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analysis strategy, which searches for a C$a$B induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a C$a$B originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband RF signals, such as other forms of a C$a$B or even high-frequency gravitational waves.

hep-ex

Optical conductivity and vibrational spectra of the narrow-gap semiconductor FeGa$_3$

Intermetallic narrow-gap semiconductors have been intensively explored due to their large thermoelectric power at low temperatures and a possible role of strong electronic correlations in their unusual thermodynamic and transport properties. Here we study the optical spectra and vibrational properties of $\mathrm{FeGa_3}$ single crystal. The optical conductivity indicates that $\mathrm{FeGa_3}$ has a direct band gap of $\sim 0.7$\,eV, consistent with density functional theory (DFT) calculations. Most importantly, we find a substantial spectral weight also below 0.4~eV, which is the energy of the indirect (charge) gap found in resistivity measurements and ab initio calculations. We find that the spectral weight below the gap decreases with increasing temperature, which indicates that it originates from the impurity states and not from the electronic correlations. Interestingly, we did not find any signatures of the impurity states in vibrational spectra. The infrared and Raman vibrational lines are narrow and weakly temperature dependent. The vibrational frequencies are in excellent agreement with our DFT calculations, implying a modest role of electronic correlations. Narrow M\" ossbauer spectral lines also indicate high crystallinity of the sample.

cond-mat.str-el

Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.

hep-ph

Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range

We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.

hep-ex

Design of the ALPS II Optical System

The Any Light Particle Search II (ALPS II) is an experiment currently being built at DESY in Hamburg, Germany, that will use a light-shining-through-a-wall (LSW) approach to search for axion-like particles. ALPS II represents a significant step forward for these types of experiments as it will use 24 superconducting dipole magnets, along with dual, high-finesse, 122 m long optical cavities. This paper gives the first comprehensive recipe for the realization of the idea, proposed over 30 years ago, to use optical cavities before and after the wall to increase the power of the regenerated photon signal. The experiment is designed to achieve a sensitivity to the coupling between axion-like particles and photons down to g=2e-11 1/GeV for masses below 0.1 meV, more than three orders of magnitude beyond the sensitivity of previous laboratory experiments. The layout and main components that define ALPS II are discussed along with plans for reaching design sensitivity. An accompanying paper (Hallal, et al [1]) offers a more in-depth description of the heterodyne detection scheme, the first of two independent detection systems that will be implemented in ALPS II.

physics.optics

Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier

We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

hep-ex

The heterodyne sensing system for the ALPS II search for sub-eV weakly interacting particles

ALPS II, the Any Light Particle Search, is a second-generation Light Shining through a Wall experiment that hunts for axion-like particles. The experiment is currently transitioning from the design and construction phase to the commissioning phase, with science runs expected to start in 2021. ALPS II plans to use two different sensing schemes to confirm the potential detection of axion-like particles or to verify an upper limit on their coupling strength to two photons of $g_{aγγ}\leq2\times10^{-11}\text{GeV}^{-1}$. This paper discusses a heterodyne sensing scheme (HET) which will be the first scheme deployed to detect the regenerated light. It presents critical details of the optical layout, the length and alignment sensing scheme, design features to minimize spurious signals from stray light, as well as several control and veto channels specific to HET which are needed to commission and operate the instrument and to calibrate the detector sensitivity.

physics.ins-det

Axion Dark Matter eXperiment: Run 1B Analysis Details

Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for Run 1B, motivating analysis choices informed by details specific to this run.

astro-ph.CO

Axion Dark Matter eXperiment: Detailed Design and Operations

Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as state-of-the-art quantum limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable Microstrip Superconducting Quantum Interference Device (SQUID) Amplifier (MSA), in Run 1A, and a Josephson Parametric Amplifier (JPA), in Run 1B, along with novel analysis tools that characterize the system noise temperature.

astro-ph.IM

ADMX SLIC: Results from a Superconducting LC Circuit Investigating Cold Axions

Axions are a promising cold dark matter candidate. Haloscopes, which use the conversion of axions to photons in the presence of a magnetic field to detect axions, are the basis of microwave cavity searches such as the Axion Dark Matter eXperiment (ADMX). To search for lighter, low frequency axions in the sub $2\times10^{-7}$ eV (50 MHz) range, a tunable lumped-element LC circuit has been proposed. For the first time, through ADMX SLIC (Superconducting Lc circuit Investigating Cold axions), a resonant LC circuit was used to probe this region of axion mass-coupling space. The detector used a superconducting LC circuit with piezoelectric driven capacitive tuning. The axion mass and corresponding frequency range $1.7498 -1.7519 \times10^{-7}$ eV (42.31 -- 42.36 MHz), $1.7734 - 1.7738 \times10^{-7}$ eV (42.88 -- 42.89 MHz), and $1.8007 - 1.8015 \times10^{-7}$ eV (43.54 -- 43.56 MHz) was covered at magnetic fields of 4.5 T, 5.0 T, and 7.0 T respectively. Exclusion results from the search data, for coupling below $10^{-12} \text{GeV}^{-1}$ are presented.

astro-ph.CO