SearcharxivSearch

arXiv subjects

D. Bhowmik

Publications and source records attributed to D. Bhowmik.

6 recordsLinked to original sources

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

physics.ins-det

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons

The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

physics.ins-det

Construction and commissioning of CMS CE prototype silicon modules

As part of its HL-LHC upgrade program, the CMS Collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.

physics.ins-det

The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.

physics.ins-det

Influence of molecular shape on self-diffusion under severe confinement: A molecular dynamics study

We have investigated the effect of molecular shape and charge asymmetry on the translation dynamics of confined hydrocarbon molecules having different shapes but similar kinetic diameters, inside ZSM-5 pores using molecular dynamics simulations. The mean square displacement of propane, acetonitrile, acetaldehyde, and acetone in ZSM-5 exhibit two different regimes - ballistic and diffusive/sub-diffusive. All the molecules except propane exhibit sub-diffusive motion at time scales greater than 1 ps. The intermediate scattering functions reveal that there is a considerable rotational- translational coupling in the motion of all the molecules, due to the strong geometrical restriction imposed by ZSM-5. Overall the difference in shape and asymmetry in charge imposes severe restriction inside the ZSM-5 channels for all the molecules to different extents. Further, the behavior of molecules confined in ZSM-5 in the present study, quantified wherever possible, is compared to their behavior in bulk or in other porous media reported in literature.

physics.chem-ph

Formulation of a Mesoscopic Electron Beam Splitter with Application in Semiconductor Based Quantum Computing

We aim to analytically arrive at a beam splitter formulation for electron waves. The electron beam splitter is an essential component of quantum logical devices. To arrive at the beam splitter structure, the electrons are treated as waves, i.e. we assume the transport to be ballistic. Ballistic electrons are electrons that travel over such short distances that their phase coherence is maintained. For mesoscopic devices with size smaller than the mean free path, the phase relaxation length and the Fermi wavelength of electrons in the medium, the transport can be considered to be coherent and hence ballistic. In such a case the electron motion can be completely described by the Schrodinger's wave equation with an effective mass assigned to the electron. To design a beam splitter, we draw inspiration from an electromagnetic beam splitter, where the Maxwell's equations (and subsequently the Helmholtz equation) are used to describe the splitting of light across a thin slab of dielectric material. The parameters of the media and the thickness of the slab can be manipulated to achieve a 50-50 beam splitter. We wish to achieve a similar 50-50 beam splitting for the electron wave. Using an analogy between the scalar Helmholtz equation and the Schrodinger's equation for a ballistic electron, we arrive at this desired beam splitter structure for the electron.

quant-ph