SearcharxivSearch

arXiv subjects

D. Chiappara

Publications and source records attributed to D. Chiappara.

4 recordsLinked to original sources

First evaluation of the tracking performance of the ARCADIA Fully Depleted MAPS with 120 GeV proton beam

This work presents test beam characterization of the ARCADIA Main Demonstrator 3, a 200 $\mu$m thick Fully Depleted MAPS developed using a custom LFoundry 110 nm CIS process on a high-resistivity substrate. Measurements using a 120 GeV proton beam demonstrate a detection efficiency exceeding 99% and a spatial resolution down to 3.8 $\mu$m. The study evaluates cluster size, spatial resolution, and efficiency as a function of the threshold, front-end currents, and backside bias voltage.

physics.ins-det

Impact of front-end parameters of the ARCADIA MD3 on charged particle detection

The ARCADIA INFN R&D project developed a Fully Depleted Monolithic Active Pixel Sensor (FD-MAPS) using a customized LFoundry 110 nm CIS process. The first in-beam characterization of the ARCADIA Main Demonstrator 3 (MD3) sensor with 200 $μ$m active thickness has been performed at the Fermilab Test Beam Facility with a 120 GeV proton beam. The Device Under Test (DUT) is tested with a trigger-less telescope composed of two ARCADIA MD3 tracking planes. This early study investigates the effect of the front-end parameters on the tracking performance.

physics.ins-det

Pixel response characterization of the ARCADIA Fully Depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a $^{55}$Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

physics.ins-det

Discussing the discrepancy between analytical calculations and the observed biological effectiveness in proton boron capture therapy (pbct)

A work recently published experimentally demonstrates an increase in the radiobiological efficacy of clinical proton beams when a tumour is treated in the presence of a concentration of 11B. The paper, for the first time, demonstrates the potential role of the p+11B to 3α (for brevity, p-B) reaction in the biological enhancement of proton therapy effectiveness. The work reports robust experimental data in terms of clonogenic cell survival and chromosomal aberrations and unambiguously shows the presence of an enhancement when cells were exposed to a clinical proton beam subject to treatment with sodium boroncaptate (BSH). Moreover, the greater occurrence of complex-type chromosomal exchanges points to the effect as due radiation of a LET (Linear Energy Transfer) greater than that of protons alone, possibly the alpha particles generated by the reaction. At the same time, we emphasized that analytical calculations, performed on the basis of the well-known total production cross section data, are not able to explain the effect in a macroscopic way, i.e. solely in terms of a trivial increase in the total dose released in the cells by the alpha-particles. In this paper, thanks to simulations and analytical calculations, we will discuss the theoretically expected alpha particle yield and the corresponding LET and RBE (Relative Biological Effectiveness) increase related to the 11B presence. We conclude that a mere calculation based on the classical concepts of integral Dose, and average LET and RBE cannot be used to justify the observed radiobiological phenomena. We, therefore, suggest that micro- and nano-dosimetric aspects must be taken into account.

physics.med-ph