SearcharxivSearch

arXiv subjects

D. Corti

Publications and source records attributed to D. Corti.

17 recordsLinked to original sources

FPGA-Based RoCEv2-RDMA Readout Electronics for the CTAO-LST Advanced Camera

CTAO's (Cherenkov Telescope Array Observatory) largest telescopes type, the LST (Large-Sized Telescope), are being installed at the northern site of the Cherenkov Telescope Array (CTA) at the Observatorio del Roque de los Muchachos on the Canary island of La Palma. Their aim is to capture the lowest-energy gamma rays of the observatory. The hereby proposed readout electronics architecture, serving as a proof-of-concept for its advanced camera upgrade, relies on a custom high-channel count fast sampling hardware digitizer board acting as a Front-End. The design includes a versatile pre-amplification stage and high-speed serial links for streaming JESD204C-compliant data at rates approaching 12 Gb/s per lane. The data get transferred to Back-End electronics for a first data-processing and trigger before being transmitted to event-building servers through 10 Gb/s Ethernet links. The performance of the link is exploited by implementing RDMA communication in hardware, thanks to a RoCEv2 core written in Bluespec SystemVerilog, enabling the possibility of transfer data directly to processing units without CPU intervention. Hardware design and characterization of the Front End board are reported, as well as a detailed description and tests of the Back End RDMA firmware.

astro-ph.IM

Development of a SiPM Pixel Prototype for the Large-Sized Telescope of the Cherenkov Telescope Array

The Cherenkov Telescope Array (CTA) will be the next generation ground-based gamma-ray observatory. CTA consists of different telescope types of which the largest ones (Large-Sized Telescopes, LSTs) cover the lower energy range, between 20 GeV and 200 GeV. The first LST is currently being commissioned at the Roque de los Muchachos Observatory, La Palma, Canary Islands. Its camera has 1855 photomultipliers (PMTs) with 1.5 inch cathodes. Silicon Photomultipliers (SiPMs) are increasingly becoming valid alternatives to PMTs also in gamma-ray astronomy. In the context of the LST project, there is an effort to study a novel Advanced Camera, equipped with SiPMs and a completely redesigned electronics based on a fully digital approach. To study and develop solutions on the sensors of these camera, we built a prototype camera module with a fully re-designed pre-amplifying stage and sensor bias control while re-using the digitizing and triggering stages of the existing LST camera module. We report on the design choices made to achieve the highest performance in terms of timing and charge resolution and the laboratory measurements validating those choices.

astro-ph.IM

The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector

The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the signals will be forwarded asynchronously to the service cavern at full resolution. The new backend system will be in charge of building the trigger primitives of each chamber. These trigger primitives contain the information at chamber level about the muon candidates position, direction, and collision time, and are used as input in the L1 CMS trigger. The added functionalities will improve the robustness of the system against ageing. An algorithm based on analytical solutions for reconstructing the DT trigger primitives, called Analytical Method, has been implemented both as a software C++ emulator and in firmware. Its performance has been estimated using the software emulator with simulated and real data samples, and through hardware implementation tests. Measured efficiencies are 96 to 98\% for all qualities and time and spatial resolutions are close to the ultimate performance of the DT chambers. A prototype chain of the HL-LHC electronics using the Analytical Method for trigger primitive generation has been installed during Long Shutdown 2 of the LHC and operated in CMS cosmic data taking campaigns in 2020 and 2021. Results from this validation step, the so-called Slice Test, are presented.

hep-ex

Development of an advanced SiPM camera for the Large Size Telescope of the Cherenkov Telescope Array

Silicon photomultipliers (SiPMs) have become the baseline choice for cameras of the small-sized telescopes (SSTs) of the Cherenkov Telescope Array (CTA). On the other hand, SiPMs are relatively new to the field and covering large surfaces and operating at high data rates still are challenges to outperform photomultipliers (PMTs). The higher sensitivity in the near infra-red and longer signals compared to PMTs result in higher night sky background rate for SiPMs. However, the robustness of the SiPMs represents a unique opportunity to ensure long-term operation with low maintenance and better duty cycle than PMTs. The proposed camera for large size telescopes will feature $0.05 degree pixels, low power and fast front-end electronics and a fully digital readout. In this work, we present the status of dedicated simulations and data analysis for the performance estimation. The design features and the different strategies identified, so far, to tackle the demanding requirements and the improved performance are described.

astro-ph.IM

Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector

To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.

physics.ins-det

Embedded Readout Electronics R&D for the Large PMTs in the JUNO Experiment

Jiangmen Underground neutrino Observatory (JUNO) is a next generation liquid scintillator neutrino experiment under construction phase in South China. Thanks to the anti-neutrinos produced by the nearby nuclear power plants, JUNO will primarily study the neutrino mass hierarchy, one of the open key questions in neutrino physics. One key ingredient for the success of the measurement is to use high speed, high resolution sampling electronics located very close to the detector signal. Linearity in the response of the electronics in another important ingredient for the success of the experiment. During the initial design phase of the electronics, a custom design, with the Front-End and Read-Out electronics located very close to the detector analog signal has been developed and successfully tested. The present paper describes the electronics structure and the first tests performed on the prototypes. The electronics prototypes have been tested and they show good linearity response, with a maximum deviation of 1.3% over the full dynamic range (1-1000 p.e.), fulfilling the JUNO experiment requirements.

physics.ins-det

Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC

The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.

physics.ins-det

$^{222}$Rn contamination mechanisms on acrylic surfaces

In this work, the $^{222}$Rn contamination mechanisms on acrylic surfaces have been investigated. $^{222}$Rn can represent a significant background source for low-background experiments, and acrylic is a suitable material for detector design thanks to its purity and transparency. Four acrylic samples have been exposed to a $^{222}$Rn rich environment for different time periods, being contaminated by $^{222}$Rn and its progenies. Subsequently, the time evolution of radiocontaminants activity on the samples has been evaluated with $α$ and $γ$ measurements, highlighting the role of different decay modes in the contamination process. A detailed analysis of the alpha spectra allowed to quantify the implantation depth of the contaminants. Moreover, a study of both $α$ and $γ$ measurements pointed out the $^{222}$Rn diffusion inside the samples.

physics.ins-det

Distillation and stripping pilot plants for the JUNO neutrino detector: design, operations and reliability

This paper describes the design, construction principles and operations of the distillation and stripping pilot plants tested at the Daya Bay Neutrino Laboratory, with the perspective to adapt this processes, system cleanliness and leak-tightness to the final full scale plants that will be used for the purification of the liquid scintillator used in the JUNO neutrino detector. The main goal of these plants is to remove radio impurities from the liquid scintillator while increasing its optical attenuation length. Purification of liquid scintillator will be performed with a system combining alumina oxide, distillation, water extraction and steam (or N2 gas) stripping. Such a combined system will aim at obtaining a total attenuation length greater than 20 m at 430 nm, and a bulk radiopurity for 238U and 232Th in the 10-15 to 10-17 g/g range. The pilot plants commissioning and operation have also provided valuable information on the degree of reliability of their main components, which will be particularly useful for the design of the final full scale purification equipment for the JUNO liquid scintillator. This paper describe two of the five pilot plants since the Alumina Column, Fluor mixing and the Water Extraction plants are in charge of the Chinese part of the collaboration.

physics.ins-det

GIGJ: a crustal gravity model of the Guangdong Province for predicting the geoneutrino signal at the JUNO experiment

Gravimetric methods are expected to play a decisive role in geophysical modeling of the regional crustal structure applied to geoneutrino studies. GIGJ (GOCE Inversion for Geoneutrinos at JUNO) is a 3D numerical model constituted by ~46 x 10$^{3}$ voxels of 50 x 50 x 0.1 km, built by inverting gravimetric data over the 6° x 4° area centered at the Jiangmen Underground Neutrino Observatory (JUNO) experiment, currently under construction in the Guangdong Province (China). The a-priori modeling is based on the adoption of deep seismic sounding profiles, receiver functions, teleseismic P-wave velocity models and Moho depth maps, according to their own accuracy and spatial resolution. The inversion method allowed for integrating GOCE data with the a-priori information and regularization conditions through a Bayesian approach and a stochastic optimization. GIGJ fits the homogeneously distributed GOCE gravity data, characterized by high accuracy, with a ~1 mGal standard deviation of the residuals, compatible with the observation accuracy. Conversely to existing global models, GIGJ provides a site-specific subdivision of the crustal layers masses which uncertainties include estimation errors, associated to the gravimetric solution, and systematic uncertainties, related to the adoption of a fixed sedimentary layer. A consequence of this local rearrangement of the crustal layer thicknesses is a ~21% reduction and a ~24% increase of the middle and lower crust expected geoneutrino signal, respectively. Finally, the geophysical uncertainties of geoneutrino signals at JUNO produced by unitary uranium and thorium abundances distributed in the upper, middle and lower crust are reduced by 77%, 55% and 78%, respectively. The numerical model is available at http://www.fe.infn.it/u/radioactivity/GIGJ

physics.geo-ph

Design of a SiPM-based cluster for the Large Size Telescope camera of CTA

A Silicon Photomultiplier (SiPM)-based photodetector is being built to demonstrate its feasibility for an alternative silicon-based camera design for the Large Size Telescope (LST) of the Cherenkov Telescope Array. It has been designed to match the size of the standard Photomultiplier Tube (PMT) cluster unit and to be compatible with mechanics, electronics and focal plane optics of the first LST camera. Here, we describe the overall SiPM cluster design along with the main differences with respect to the currently used PMT cluster unit. The fast electronics of the SiPM pixel and its layout are also presented. In order to derive the best working condition for the final unit, we measured the SiPM performances in terms of gain, photo-detection efficiency and cross-talk. One pixel, a unit of 14 SiPMs, has been built. We will discuss also some preliminary results regarding this device and we will highlight the future steps of this project.

astro-ph.IM

Nanoseconds Timing System Based on IEEE 1588 FPGA Implementation

Clock synchronization procedures are mandatory in most physical experiments where event fragments are readout by spatially dislocated sensors and must be glued together to reconstruct key parameters (e.g. energy, interaction vertex etc.) of the process under investigation. These distributed data readout topologies rely on an accurate time information available at the frontend, where raw data are acquired and tagged with a precise timestamp prior to data buffering and central data collecting. This makes the network complexity and latency, between frontend and backend electronics, negligible within upper bounds imposed by the frontend data buffer capability. The proposed research work describes an FPGA implementation of IEEE 1588 Precision Time Protocol (PTP) that exploits the CERN Timing, Trigger and Control (TTC) system as a multicast messaging physical and data link layer. The hardware implementation extends the clock synchronization to the nanoseconds range, overcoming the typical accuracy limitations inferred by computers Ethernet based Local Area Network (LAN). Establishing a reliable communication between master and timing receiver nodes is essential in a message-based synchronization system. In the backend electronics, the serial data streams synchronization with the global clock domain is guaranteed by an hardware-based finite state machine that scans the bit period using a variable delay chain and finds the optimal sampling point. The validity of the proposed timing system has been proved in point-to-point data links as well as in star topology configurations over standard CAT-5e cables. The results achieved together with weaknesses and possible improvements are hereby detailed.

cs.NI

Charge reconstruction in large-area photomultipliers

Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrinos' extremely elusive nature. Depending on the detector light yield, several scintillation photons stemming from the same neutrino interaction are likely to hit a single PMT in a few tens/hundreds of nanoseconds, resulting in several photoelectrons (PEs) to pile-up at the PMT anode. In such scenario, the signal generated by each PE is entangled to the others, and an accurate PMT charge reconstruction becomes challenging. This manuscript describes an experimental method able to address the PMT charge reconstruction in the case of large PE pile-up, providing an unbiased charge estimator at the permille level up to 15 detected PEs. The method is based on a signal filtering technique (Wiener filter) which suppresses the noise due to both PMT and readout electronics, and on a Fourier-based deconvolution able to minimize the influence of signal distortions ---such as an overshoot. The analysis of simulated PMT waveforms shows that the slope of a linear regression modeling the relation between reconstructed and true charge values improves from $0.769 \pm 0.001$ (without deconvolution) to $0.989 \pm 0.001$ (with deconvolution), where unitary slope implies perfect reconstruction. A C++ implementation of the charge reconstruction algorithm is available online at http://www.fe.infn.it/CRA .

physics.ins-det

Studies on a silicon-photomultiplier-based camera for Imaging Atmospheric Cherenkov Telescopes

Imaging Atmospheric Cherenkov Telescopes (IACTs) represent a class of instruments which are dedicated to the ground-based observation of cosmic VHE gamma ray emission based on the detection of the Cherenkov radiation produced in the interaction of gamma rays with the Earth atmosphere. One of the key elements of such instruments is a pixelized focal-plane camera consisting of photodetectors. To date, photomultiplier tubes (PMTs) have been the common choice given their high photon detection efficiency (PDE) and fast time response. Recently, silicon photomultipliers (SiPMs) are emerging as an alternative. This rapidly evolving technology has strong potential to become superior to that based on PMTs in terms of PDE, which would further improve the sensitivity of IACTs, and see a price reduction per square millimeter of detector area. We are working to develop a SiPM-based module for the focal-plane cameras of the MAGIC telescopes to probe this technology for IACTs with large focal plane cameras of an area of few square meters. We will describe the solutions we are exploring in order to balance a competitive performance with a minimal impact on the overall MAGIC camera design using ray tracing simulations. We further present a comparative study of the overall light throughput based on Monte Carlo simulations and considering the properties of the major hardware elements of an IACT.

astro-ph.IM

The major upgrade of the MAGIC telescopes, Part I: The hardware improvements and the commissioning of the system

The MAGIC telescopes are two Imaging Atmospheric Cherenkov Telescopes (IACTs) located on the Canary island of La Palma. The telescopes are designed to measure Cherenkov light from air showers initiated by gamma rays in the energy regime from around 50 GeV to more than 50 TeV. The two telescopes were built in 2004 and 2009, respectively, with different cameras, triggers and readout systems. In the years 2011-2012 the MAGIC collaboration undertook a major upgrade to make the stereoscopic system uniform, improving its overall performance and easing its maintenance. In particular, the camera, the receivers and the trigger of the first telescope were replaced and the readout of the two telescopes was upgraded. This paper (Part I) describes the details of the upgrade as well as the basic performance parameters of MAGIC such as raw data treatment, dead time of the system, linearity in the electronic chain and sources of noise. In Part II, we describe the physics performance of the upgraded system.

astro-ph.IM

The major upgrade of the MAGIC telescopes, Part II: A performance study using observations of the Crab Nebula

MAGIC is a system of two Imaging Atmospheric Cherenkov Telescopes located in the Canary island of La Palma, Spain. During summer 2011 and 2012 it underwent a series of upgrades, involving the exchange of the MAGIC-I camera and its trigger system, as well as the upgrade of the readout system of both telescopes. We use observations of the Crab Nebula taken at low and medium zenith angles to assess the key performance parameters of the MAGIC stereo system. For low zenith angle observations, the standard trigger threshold of the MAGIC telescopes is ~50GeV. The integral sensitivity for point-like sources with Crab Nebula-like spectrum above 220GeV is (0.66+/-0.03)% of Crab Nebula flux in 50 h of observations. The angular resolution, defined as the sigma of a 2-dimensional Gaussian distribution, at those energies is < 0.07 degree, while the energy resolution is 16%. We also re-evaluate the effect of the systematic uncertainty on the data taken with the MAGIC telescopes after the upgrade. We estimate that the systematic uncertainties can be divided in the following components: < 15% in energy scale, 11-18% in flux normalization and +/-0.15 for the energy spectrum power-law slope.

astro-ph.IM

Measurements and tests on FBK silicon sensors with an optimized electronic design for a CTA camera

In October 2013, the Italian Ministry approved the funding of a Research & Development (R&D) study, within the "Progetto Premiale TElescopi CHErenkov made in Italy (TECHE)", devoted to the development of a demonstrator for a camera for the Cherenkov Telescope Array (CTA) consortium. The demonstrator consists of a sensor plane based on the Silicon Photomultiplier (SiPM) technology and on an electronics designed for signal sampling. Preliminary tests on a matrix of sensors produced by the Fondazione Bruno Kessler (FBK-Trento, Italy) and on electronic prototypes produced by SITAEL S.p.A. will be presented. In particular, we used different designs of the electronics in order to optimize the output signals in terms of tail cancellation. This is crucial for applications where a high background is expected, as for the CTA experiment.

astro-ph.IM