SearcharxivSearch

arXiv subjects

D. Douillet

Publications and source records attributed to D. Douillet.

9 recordsLinked to original sources

Operation and performance of the Probe for Luminosity Measurement at LHCb

The Probe for LUminosity MEasurement (PLUME) detector is a dedicated luminosity monitor at the LHCb interaction point. It is a hodoscope comprising 48 Hamamatsu R760 photomultiplier tubes that detect Cherenkov light produced by particles travelling in the direction opposite to the LHCb spectrometer acceptance. PLUME provides real-time, bunch-by-bunch luminosity measurements during LHCb data taking and serves as the primary detector for controlling the luminosity levelling process at LHCb. In addition, its data are used offline, together with other dedicated counters from LHCb sub-systems, to determine the integrated luminosity delivered to the experiment. This paper reports on the detector's operational performance during the 2024-2026 data-taking period of Run 3. The integrated luminosity recorded by the LHCb experiment in $pp$ collisions at $\sqrt{s} = 13.6$ TeV during this period, as measured by the PLUME online luminosity counters for detector performance monitoring, amounts to $\mathcal{L} = (26.71 \pm 1.07)$ fb$^{-1}$. The luminosity values used in physics analyses are determined separately through dedicated offline calibrations based on van der Meer scans and Beam Gas Imaging techniques, and will be reported in a dedicated publication, as they are beyond the scope of this paper.

hep-ex

Technical Status Report on Plasma Components and Systems in the context of EuPRAXIA

The EuPRAXIA project aims to construct two state-of-the-art accelerator facilities based on plasma accelerator technology. Plasma-based accelerators offer the possibility of a significant reduction in facility size and cost savings over current radio frequency (RF) accelerators. The two facilities - one laser-driven one a beam-driven - are envisioned to provide electron beams with an energy in the range of 1-5 GeV and beam quality comparable to existing RF machines. This will enable a versatile portfolio of applications from compact free-electron laser (FEL) drivers to sources for medical and industrial imaging. At the heart of both facilities is the use of plasma-based accelerator components and systems which encompass not only the accelerating medium itself, but also a range of auxiliary systems such as plasma-based electron beam optics and plasma-based mirrors for high-intensity lasers. From a technical standpoint, a high-degree of control over these plasma devices will be essential for EuPRAXIA to achieve its target performance goals. The ability to diagnose and characterize these plasma devices and to simulate their operation will be further essential success factors. Additionally, compatibility with extended operation at high-repetition rates and integration into the accelerator beamline will also prove crucial. In this work, we aim to review the current status of plasma components and related systems for both laser-driven and beam-driven plasma accelerators and to assess challenges to be addressed regarding implementation at future EuPRAXIA facilities.

physics.plasm-ph

The XENONnT Dark Matter Experiment

The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.

physics.ins-det

Two-chamber gas target for laser-plasma accelerator electron source

Exploring new target schemes for laser wakefield accelerators is essential to meet the challenge of increasing repetition rates while ensuring stability and quality of the produced electron beams. The prototyping of a two-chamber gas cell integrated into the beam line and operating in continuous gas flow is introduced and discussed in the frame of ionisation injection. We report the numerical fluid modeling used to assist the density profile shaping. We describe the test bench used for cell prototype assessment, in particular the plasma electron density and longitudinal distribution of species relevant for ionisation injection. The lifetime of the target key part is measured for different materials. Perspectives to high power operation are outlined.

physics.acc-ph

Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering

We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would benefit from a depleted target. A high-statistics observation of $pp$ neutrinos would allow us to infer the values of the weak mixing angle, $\sin^2θ_w$, and the electron-type neutrino survival probability, $P_e$, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, at an exposure of 300 ty. An observation of $pp$ and $^7$Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high (GS98) and low metallicity (AGS09) solar models with 2.1-2.5$σ$ significance, independent of external measurements from other experiments or a measurement of $^8$B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of $^{131}$Xe.

physics.ins-det

Modelling of laser-plasma acceleration of relativistic electrons in the frame of ESCULAP project

We present numerical simulations results on the injection and acceleration of a 10 MeV, 10 pC electrons beam in a plasma wave generated in a gas cell by a 2J, 45 fs laser beam. This modeling is related to the ESCULAP project in which the electrons accelerated by the PHIL photo-injector is injected in a gas cell irradiated by the laser beam of the LASERIX system. Extensive modeling of the experiment was performed in order to determine optimal parameters of the laser plasma configurations. This was done with the newly developed numerical code WakeTraj . We propose a configuration that benefits of a highly compressed electron bunch and for which the injected electron beam can be efficiently coupled to the plasma wave and accelerated up to 140 MeV, with an energy spread lower than 5%.

physics.acc-ph

Longitudinal compression and transverse matching of electron bunch for external injection LPWA at ESCULAP

We present theoretical and numerical studies of longitudinal compression and transverse matching of electron bunch before injecting into the Laser-plasma Wake Field Accelerator (LWFA) foreseen at the ESCULAP project in ORSAY. Longitudinal compression is performed with a dogleg chicane, the chicane is designed based on theory of beam optics, beam dynamics in dogleg is studied with ImpactT and cross checked with CSRtrack, both 3D space charge (SC) and coherent synchrotron radiation (CSR) effects are included. Simulation results show that the energy chirp at the dogleg entrance should be smaller than the nominal optic design value, in order to compensate the negative energy chirp increase caused by longitudinal SC, while CSR can be ignored in our case. With an optimized configuration, the electron bunch ($\sim$10MeV, 10pC) is compressed from 0.9ps RMS to 70fs RMS (53fs FWHM), with a peak current of 152A. Transverse matching is realized with a doublet and a triplet, they are matched with Madx and the electron bunch is tracked with ImpactT, simulation results show little difference with the nominal design values, that is due to the SC effect. Finally, by simply adjusting the quadrupole strength, a preliminary optimized configuration has been achieved, that matches the Courant-Snyder (C-S) parameters to $α_{x}=0.01$,$α_{y}=-0.02$, $β_{x}=0.014$m,$β_{y}=0.012$m at the plasma entrance.

physics.acc-ph

Effect of the laser wavefront in a laser-plasma accelerator

A high repetition rate electron source was generated by tightly focusing kHz, few-mJ laser pulses into an underdense plasma. This high intensity laser-plasma interaction led to stable electron beams over several hours but with strikingly complex transverse distributions even for good quality laser focal spots. Analysis of the experimental data, along with results of PIC simulations demonstrate the role of the laser wavefront on the acceleration of electrons. Distortions of the laser wavefront cause spatial inhomogeneities in the out-of-focus laser distribution and consequently, the laser pulse drives an inhomogenous transverse wakefield whose focusing/defocusing properties affect the electron distribution. These findings explain the experimental results and suggest the possibility of controlling the electron spatial distribution in laser-plasma accelerators by tailoring the laser wavefront.

physics.acc-ph

Observation of longitudinal and transverse self-injections in laser-plasma accelerators

Laser-plasma accelerators can produce high quality electron beams, up to giga-electronvolts in energy, from a centimeter scale device. The properties of the electron beams and the accelerator stability are largely determined by the injection stage of electrons into the accelerator. The simplest mechanism of injection is self-injection, in which the wakefield is strong enough to trap cold plasma electrons into the laser wake. The main drawback of this method is its lack of shot-to-shot stability. Here we present experimental and numerical results that demonstrate the existence of two different self-injection mechanisms. Transverse self-injection is shown to lead to low stability and poor quality electron beams, because of a strong dependence on the intensity profile of the laser pulse. In contrast, longitudinal injection, which is unambiguously observed for the first time, is shown to lead to much more stable acceleration and higher quality electron beams.

physics.plasm-ph