Final results of the EDELWEISS-I dark matter search with cryogenic heat-and-ionization Ge detectors

The final results of the EDELWEISS-I dark matter search using cryogenic heat-and-ionization Ge detectors are presented. The final data sample corresponds to an increase by a factor five in exposure relative to the previously published results. A recoil energy threshold of 13 keV or better was achieved with three 320g detectors working simultaneously over four months of stable operation. Limits on the spin-independent cross-section for the scattering of a WIMP on a nucleon are derived from an accumulated fiducial exposure of 62 kg.d.

astro-ph

Sensitivity of the EDELWEISS WIMP search to spin-dependent interactions

The EDELWEISS collaboration is searching for WIMP dark matter using natural Ge cryogenic detectors. The whole data set of the first phase of the experiment contains a fiducial exposure of 4.8 kg.day on Ge-73, the naturally present (7.8%), high-spin Ge isotope. The sensitivity of the experiment to the spin-dependent WIMP-nucleon interactions is evaluated using the model-independent framework proposed by Tovey et al.

astro-ph

SICANE: a Detector Array for the Measurement of Nuclear Recoil Quenching Factors using Monoenergetic Neutron Beam

SICANE is a neutron scattering multidetector facility for the determination of the quenching factor (ratio of the response to nuclear recoils and to electrons) of cryogenic detectors used in direct WIMP searches. Well collimated monoenergetic neutron beams are obtained with inverse (p,n) reactions. The facility is described, and results obtained for the quenching factors of scintillation in NaI(Tl) and of heat and ionization in Ge are presented.

astro-ph

Improved Exclusion Limits from the EDELWEISS WIMP Search

The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a heat-and-ionization cryogenic Ge detector operated in the low-background environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel, during an effective exposure of 7.4 kg.days. This result is combined with the previous EDELWEISS data to derive a limit on the cross-section for spin-independent interaction of WIMPs and nucleons as a function of WIMP mass, using standard nuclear physics and astrophysical assumptions. This limit excludes at more than 99.8%CL a WIMP candidate with a mass of 44 GeV/c2 and a cross-section of 5.4 x 10-6 pb, as reported by the DAMA collaboration. A first sample of supersymmetric models are also excluded at 90%CL.

astro-ph

First Results of the EDELWEISS WIMP Search using a 320 g Heat-and-Ionization Ge Detector

The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are observed in the fiducial volume in the 30-200 keV energy range during an effective exposure of 4.53 kg.days. Limits for the cross-section for the spin-independent interaction of WIMPs and nucleons are set in the framework of the Minimal Supersymmetric Standard Model (MSSM). The central value of the signal reported by the experiment DAMA is excluded at 90% CL.

astro-ph

Dark Matter Search in the EDELWEISS experiment

The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat and ionisation read-out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Preliminary results obtained with 320g bolometers are described. After a few weeks of data taking, data accumulated with one of these detectors already allow to reach the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.

astro-ph

Dark Matter Search in the Edelweiss Experiment

Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of the DAMA region. Prospects for the present run and the second stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data taking with 100 detectors, are briefly described.

astro-ph

The EDELWEISS Experiment : Status and Outlook

The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g Ge detectors in the low-background environment of the Modane Underground Laboratory (LSM) are presented.

astro-ph

Background discrimination capabilities of a heat and ionization germanium cryogenic detector

The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of WIMPs. Gamma and neutron calibrations demonstrate that this type of detector is able to reject more than 99.6% of the background while retaining 95% of the signal, provided that the background events distribution is not biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data taken in a relatively important radioactive environment show an extra population slightly overlapping the signal. This background is likely due to interactions of low energy photons or electrons near the surface of the crystal, and is somewhat reduced by applying a higher charge-collecting inverse bias voltage (-6 V instead of -2 V) to the Ge diode. Despite this contamination, more than 98% of the background can be rejected while retaining 50% of the signal. This yields a conservative upper limit of 0.7 event.day^{-1}.kg^{-1}.keV^{-1}_{recoil} at 90% confidence level in the 15-45 keV recoil energy interval; the present sensitivity appears to be limited by the fast ambient neutrons. Upgrades in progress on the installation are summarized.

astro-ph

Event categories in the EDELWEISS WIMP search experiment

Four categories of events have been identified in the EDELWEISS-I dark matter experiment using germanium cryogenic detectors measuring simultaneously charge and heat signals. These categories of events are interpreted as electron and nuclear interactions occurring in the volume of the detector, and electron and nuclear interactions occurring close to the surface of the detectors(10-20 mu-m of the surface). We discuss the hypothesis that low energy surface nuclear recoils,which seem to have been unnoticed by previous WIMP searches, may provide an interpretation of the anomalous events recorded by the UKDMC and Saclay NaI experiments. The present analysis points to the necessity of taking into account surface nuclear and electron recoil interactions for a reliable estimate of background rejection factors.

astro-ph

Status of the EDELWEISS Experiment

The status of the EDELWEISS experiment (underground dark matter search with heat-ionisation bolometers) is reviewed. Auspicious results achieved with a prototype 70 g Ge heat-ionisation detector under a 2 V reverse bias tension are discussed. Based on gamma and neutron calibrations, a best-case rejection factor, over the 15-45 keV range, of 99.7 % for gammas, with an acceptance of 94 % for neutrons, is presented first. Some operational results of physical interest obtained under poor low radioactivity conditions follow. They include a raw event rate of around 30 events/day/kg/keV over the same energy range, and, after rejection of part of the background, lead to a conservative upper limit on the signal of approximately 1.6 events/day/kg/keV at a 90 % confidence level. Performance degrading surface effects of the detector are speculated upon; and planned upgrades are summarized.

astro-ph