SearcharxivSearch

arXiv subjects

D. Fink

Publications and source records attributed to D. Fink.

At least 19 recordsLinked to original sources

Performance of MAGIC stellar intensity interferometer and expansion to MAGIC + CTAO-LST1 stellar intensity interferometer

A new generation of optical intensity interferometers are emerging in recent years taking advantage of the existing infrastructure of Imaging Atmospheric Cherenkov Telescopes (IACTs). The MAGIC SII (Stellar Intensity Interferometer) in La Palma, Spain, has been operating since its first successful measurements in 2019 and its current design allows it to operate regularly. The current setup is ready to follow up on bright optical transients, as changing from regular gamma-ray observations to SII mode can be done in a matter of minutes. A paper studying the system performance, first measurements and future upgrades has been recently published. MAGIC SII's first scientific results are the measurement of the angular size of 22 stars, 13 of which with no previous measurements in the B band. More recently the Large Sized Telescope prototype from the Cherenkov Telescope Array Observatory (CTAOLST1) has been upgraded to operate together with MAGIC as a SII, leading to its first correlation measurements at the beginning of 2024. MAGIC+CTAO-LST1 SII will be further upgraded by adding the remaining CTAOLSTs at the north site to the system (which are foreseen to be built by the end of 2025). MAGIC+CTAO-LST1 SII shows a feasible technical solution to extend SII to the whole CTAO.

astro-ph.IM

Direct Comparison of SiPM and PMT Sensor Performances in a large-size imaging air Cherenkov telescope

The peak photon detection efficiency (PDE) of silicon photomultipliers (SiPMs) can be as good or better than the PDE of photomultiplier tubes (PMTs). There are experiments where the signal is measured in the presence of a strong, steady background light emission. In these, one needs to accurately evaluate the signal-to-noise ratio. Imaging Atmospheric Cherenkov Telescopes (IACTs) observe in the presence of strong noise induced by the light of the night sky. It is certainly interesting to investigate the SiPM performance under operational conditions of IACTs and to compare it with that of the PMTs. For that purpose, we built a SiPM-based detector module, which was installed in one of the imaging cameras of the two Major Atmospheric Gamma-ray Imaging Cherenkov (MAGIC) telescopes in 2015. The experience gained from that module was used to design the second generation of modules of improved performance. Two such modules were installed in 2017. MAGIC is a system of two IACTs located on the Canary Island of La Palma. The mechanical structure of the MAGIC imaging cameras offers the possibility to install up to 6 additional detector modules of 7 pixels each into the open vertices of the hexagonal-shaped camera. This allows us to directly, without making any assumption, compare the performance of the PMT-based modules with that of the SiPM-based prototype modules, where SiPMs from three different manufacturers are used.

astro-ph.IM

First measurements and upgrade plans of the MAGIC intensity interferometer

The two MAGIC 17-m diameter Imaging Atmospheric Cherenkov Telescopes have been equipped to work also as an intensity interferometer with a deadtime-free, 4-channel, GPU-based, real-time correlator. Operating with baselines between approx. 40 and 90 m the MAGIC interferometer is able to measure stellar diameters of 0.5-1 mas in the 400-440 nm wavelength range with a sensitivity roughly 10 times better than that achieved in the 1970s by the Narrabri Stellar Intensity Interferometer. Besides, active mirror control allows to split the primary mirrors into sub-mirrors. This allows to make simultaneous calibration measurements of the zero-baseline correlation or to simultaneously collect six baselines below 17 m with almost arbitrary orientation, corresponding to angular scales of approx. 1-50 mas. We plan to perform test observations adding the nearby Cherenkov Telescope Array (CTA) LST-1 23 m diameter telescope by next year. All three telescope pairs will be correlated simultaneously. Adding LST-1 is expected to increase the sensitivity by at least 1 mag and significantly improve the u-v plane coverage. If successful, the proposed correlator setup is scalable enough to be implemented to the full CTA arrays.

astro-ph.IM

KATRIN: Status and Prospects for the Neutrino Mass and Beyond

The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN's design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.

nucl-ex

Characterization of Silicon Drift Detectors with Electrons for the TRISTAN Project

Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A promising model-independent way to search for sterile neutrinos is via high-precision beta spectroscopy. The Karlsruhe Tritium Neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector's response to electrons on the final sterile neutrino sensitivity.

physics.ins-det

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless $\beta\beta$ Decay, is a ton-scale experimental program to search for neutrinoless double beta ($0\nu\beta\beta$) decay in the isotope $^{76}$Ge with an unprecedented sensitivity. Building on the success of the low-background $^{76}$Ge-based GERDA and MAJORANA DEMONSTRATOR experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond $10^{28}\,$yr on the decay half-life with approximately $10\,\text{t}\cdot\text{yr}$ of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

physics.ins-det

Optical intensity interferometry observations using the MAGIC imaging atmospheric Cherenkov telescopes

Imaging Atmospheric Cherenkov Telescopes (IACTs) currently in operation feature large mirrors and order of 1 ns time response to signals of a few photo-electrons produced by optical photons. This means that they are ideally suited for optical interferometry observations. Thanks to their sensitivity to visible wavelengths and long baselines optical intensity interferometry with IACTs allows reaching angular resolutions of tens to microarcsec. We have installed a simple optical setup on top of the cameras of the two 17 m diameter MAGIC IACTs and observed coherent fluctuations in the photon intensity measured at the two telescopes for three different stars. The sensitivity is roughly 10 times better than that achieved in the 1970s with the Narrabri interferometer.

astro-ph.IM

"Birds in the Clouds": Adventures in Data Engineering

Leveraging their eBird crowdsourcing project, the Cornell Lab of Ornithology generates sophisticated Spatio-Temporal Exploratory Model (STEM) maps of bird migrations. Such maps are highly relevant for both scientific and educational purposes, but creating them requires advanced modeling techniques that rely on long and potentially expensive computations. In this paper, we share our experience porting the eBird STEM data pipeline from a physical cluster to the cloud, providing a seamless deployment at a lower cost. Using open source tools and cloud "marketplaces", we managed to divide the operating costs by a factor of 6, making it possible to scale our pipeline on a research budget.

cs.CY

Light-Trap: A SiPM Upgrade for Very High Energy Astronomy and Beyond

With the development of the Imaging Atmospheric Cherenkov Technique (IACT), Gamma-ray astronomy has become one of the most interesting and productive fields of astrophysics. Current IACT telescope arrays (MAGIC, H.E.S.S, VERITAS) use photomultiplier tubes (PMTs) to detect the optical/near-UV Cherenkov radiation emitted due to the interaction of gamma rays with the atmosphere. For the next generation of IACT experiments, the possibility of replacing the PMTs with Silicon photomultipliers (SiPMs) is being studied. Among the main drawbacks of SiPMs are their limited active area (leading to an increase in the cost and complexity of the camera readout) and their sensitivity to unwanted wavelengths. Here we propose a novel method to build a relatively low-cost pixel consisting of a SiPM attached to a PMMA disc doped with a wavelength shifter. This pixel collects light over a much larger area than a single standard SiPM and improves sensitivity to near-UV light while simultaneously rejecting background. We describe the design of a detector that could also have applications in other fields where detection area and cost are crucial. We present results of simulations and laboratory measurements of a pixel prototype and from field tests performed with a 7-pixel cluster installed in a MAGIC telescope camera.

astro-ph.IM

MAGIC sensitivity to millisecond-duration optical pulses

The MAGIC telescopes are a system of two Imaging Atmospheric Cherenkov Telescopes (IACTs) designed to observe very high energy (VHE) gamma rays above ~50 GeV. However, as IACTs are sensitive to Cherenkov light in the UV/blue and use photo-detectors with a time response well below the ms scale, MAGIC is also able to perform simultaneous optical observations. Through an alternative system installed in the central PMT of MAGIC II camera, the so-called central pixel, MAGIC is sensitive to short (1ms - 1s) optical pulses. Periodic signals from the Crab pulsar are regularly monitored. Here we report for the first time the experimental determination of the sensitivity of the central pixel to isolated 1-10 ms long optical pulses. The result of this study is relevant for searches of fast transients such as Fast Radio Bursts (FRBs).

astro-ph.IM

The major upgrade of the MAGIC telescopes, Part I: The hardware improvements and the commissioning of the system

The MAGIC telescopes are two Imaging Atmospheric Cherenkov Telescopes (IACTs) located on the Canary island of La Palma. The telescopes are designed to measure Cherenkov light from air showers initiated by gamma rays in the energy regime from around 50 GeV to more than 50 TeV. The two telescopes were built in 2004 and 2009, respectively, with different cameras, triggers and readout systems. In the years 2011-2012 the MAGIC collaboration undertook a major upgrade to make the stereoscopic system uniform, improving its overall performance and easing its maintenance. In particular, the camera, the receivers and the trigger of the first telescope were replaced and the readout of the two telescopes was upgraded. This paper (Part I) describes the details of the upgrade as well as the basic performance parameters of MAGIC such as raw data treatment, dead time of the system, linearity in the electronic chain and sources of noise. In Part II, we describe the physics performance of the upgraded system.

astro-ph.IM

The major upgrade of the MAGIC telescopes, Part II: A performance study using observations of the Crab Nebula

MAGIC is a system of two Imaging Atmospheric Cherenkov Telescopes located in the Canary island of La Palma, Spain. During summer 2011 and 2012 it underwent a series of upgrades, involving the exchange of the MAGIC-I camera and its trigger system, as well as the upgrade of the readout system of both telescopes. We use observations of the Crab Nebula taken at low and medium zenith angles to assess the key performance parameters of the MAGIC stereo system. For low zenith angle observations, the standard trigger threshold of the MAGIC telescopes is ~50GeV. The integral sensitivity for point-like sources with Crab Nebula-like spectrum above 220GeV is (0.66+/-0.03)% of Crab Nebula flux in 50 h of observations. The angular resolution, defined as the sigma of a 2-dimensional Gaussian distribution, at those energies is < 0.07 degree, while the energy resolution is 16%. We also re-evaluate the effect of the systematic uncertainty on the data taken with the MAGIC telescopes after the upgrade. We estimate that the systematic uncertainties can be divided in the following components: < 15% in energy scale, 11-18% in flux normalization and +/-0.15 for the energy spectrum power-law slope.

astro-ph.IM

The Cherenkov Telescope Array Large Size Telescope

The two arrays of the Very High Energy gamma-ray observatory Cherenkov Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA to achieve a low-energy threshold of 20 GeV, which is critical for important studies in astrophysics, astroparticle physics and cosmology. This work presents the key specifications and performance of the current LST design in the light of the CTA scientific objectives.

astro-ph.IM

Development of the Photomultiplier-Tube Readout System for the CTA Large Size Telescope

We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact, low noise and wide dynamic range gain block. The output of this block is then digitized at a sampling rate of the order of GHz using the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer Institute. The sampler has 1,024 capacitors per channel and four channels are cascaded for increased depth. After a trigger is generated in the system, the charges stored in the capacitors are digitized by an external slow sampling ADC and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4, trigger threshold, and Ethernet transfer. In addition, the control and monitoring of the Cockcroft-Walton circuit that provides high voltage for the 7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been developed that has successfully sampled PMT signals at a rate of 2 GHz, and generated single photoelectron spectra.

astro-ph.IM

Q-Value and Half-Lives for the Double-Beta-Decay Nuclide 110Pd

The 110Pd double-beta decay Q-value was measured with the Penning-trap mass spectrometer ISOLTRAP to be Q = 2017.85(64) keV. This value shifted by 14 keV compared to the literature value and is 17 times more precise, resulting in new phase-space factors for the two-neutrino and neutrinoless decay modes. In addition a new set of the relevant matrix elements has been calculated. The expected half-life of the two-neutrino mode was reevaluated as 1.5(6) E20 yr. With its high natural abundance, the new results reveal 110Pd to be an excellent candidate for double-beta decay studies.

nucl-ex

Development of HPD Clusters for MAGIC-II

MAGIC-II is the second imaging atmospheric Cherenkov telescope of the MAGIC observatory, which has recently been inaugurated on Canary island of La Palma. We are currently developing a new camera based on clusters of hybrid photon detectors (HPD) for the upgrade of MAGIC-II. The photon detectors feature a GaAsP photocathode and an avalanche diode as electron bombarded anodes with internal gain, and were supplied by Hamamatsu Photonics K.K. (R9792U-40). The HPD camera with high quantum efficiency will increase the MAGIC-II sensitivity and lower the energy threshold. The basic performance of the HPDs has been measured and a prototype of an HPD cluster has been developed to be mounted on MAGIC-II. Here we report on the status of the HPD cluster and the project of eventually using HPD clusters in the central area of the MAGIC-II camera.

astro-ph.IM

Performance of the Camera of the MAGIC II Telescope

MAGIC comprises two 17m diameter IACTs to be operated in stereo mode. Currently we are commissioning the second telescope, MAGIC II. The camera of the second telescope has been equipped with 1039 pixels of 0.1-degree diameter. Always seven pixels are grouped in a hexagonal configuration to form a cluster. This modular design allows easier control and maintenance of the camera. The pixel sensors are high quantum efficiency photomultiplier tubes (PMTs) from Hamamatsu (superbialkali type, QE ~ 32% at the peak wavelength) that we operate at rather low gain of 30 k. This allows us to also perform extended observations under moderate moonlight. The system of two MAGIC telescopes will at least double the sensitivity compared to MAGIC I and also will allow us to lower the energy threshold.Here we will report the performances of the Camera of the second MAGIC telescope.

astro-ph.HE

The Camera of the MAGIC-II Telescope

The MAGIC 17m diameter Cherenkov telescope will be upgraded with a second telescope within the year 2007. The camera of MAGIC-II will include several new features compared to the MAGIC-I camera. Photomultipliers with the highest available photon collection efficiency have been selected. A modular design allows easier access and flexibility to test new photodetector technologies. The camera will be uniformly equipped with 0.1 degree diamter pixels, which allows the use of an increased trigger area. Finally, the overall signal chain features a large bandwidth to retain the shape of the very fast Cherenkov signals.

astro-ph