Publications and source records attributed to D. G. Ang.

3 recordsLinked to original sources

Compact Actively-Shielded Magnetic Field Coil within Mu-Metal Shields for ACME Electric Dipole Moment Measurements

A system of actively-shielded coils and mu-metal shields is devised, constructed and shown to provide the stable and spatially uniform magnetic field needed for the ACME III electron electric dipole moment (eEDM) measurement. Two layers of current-carrying coils, enclosed within three layers of ferromagnetic shields, produce a field that varies by less than 1 nT (10 $\uG$) within the 1 m $\times$ 4.2 cm $\times$ 4.2 cm interior volume in which a beam of ThO molecules are probed as they precess. The demountable shields are constructed from rectangular mu-metal plates. The largest, with a mass of 19 kg and an area of 2.18 m $\times$ 0.75 m, is easily carried by two people and just fits within a large available annealing oven. The assembly design facilitates low-stress mounting and handling to suppress changes in the magnetic properties of the mu metal, and also provides modular access to apparatus within the coils for maintenance and upgrades. The nearly static external ambient field is reduced within the shielded precession volume by up to a factor of $10^5$. During the magnetic field reversals that ACME uses to suppress systematic uncertainties, the ``actively-shielded'' coil largely cancels out its external fringing field to minimize the magnetization of the mu metal. Even though the shields are only 10 cm outside the coils, shield degaussing after every magnetic field reversal is not required. The non-reversing residual field stays below 1 nT for up to 17 hours when the field is reversed every 30 seconds, for example. The measured performance, compared to the previous generation ACME II apparatus, suggests that the magnetic-field-related systematic uncertainties for ACME III will be smaller by an estimated factor of 40 despite a five times longer precession volume and the use of three magnetic shielding layers rather than five.

physics.atom-ph

SiPM module for the ACME III electron EDM search

This report shows the design and the performance of a large area Silicon Photomultiplier (SiPM) module developed detection of fluorescent light emitted from a 10 cm scale volume. The module was optimized for the planned ACME III electron electric dipole moment (eEDM) search, which will be a powerful probe for the existence of physics beyond the Standard Model of particle physics. The ACME experiment searched for the eEDM with the world's highest sensitivity using cold ThO polar molecules (ACME II). In ACME III, SiPMs will be used for detection of fluorescent photons (the fundamental signal of the experiment) instead of PMTs, which were used in the previous measurement. We have developed an optimized SiPM module, based on a 16-channel SiPM array. Key operational parameters are characterized, including gain and noise. The SiPM dark count rate, background light sensitivity, and optical crosstalk are found to all be well suppressed and more than sufficient for the ACME III application.

physics.ins-det

Attaining the shot-noise-limit in the ACME measurement of the electron electric dipole moment

Experimental searches for the electron electric dipole moment, $d_e$, probe new physics beyond the Standard Model. Recently, the ACME Collaboration set a new limit of $|d_e| <1.1\times 10^{-29}$ $e\cdot \textrm{cm}$ [Nature $\textbf{562}$, 355 (2018)], constraining time reversal symmetry (T) violating physics in the 3-100 TeV energy scale. ACME extracts $d_e$ from the measurement of electron spin precession due to the thorium monoxide (ThO) molecule's internal electric field. This recent ACME II measurement achieved an order of magnitude increased sensitivity over ACME I by reducing both statistical and systematic uncertainties in the measurement of the electric dipole precession frequency. The ACME II statistical uncertainty was a factor of 1.7 above the ideal shot-noise limit. We have since traced this excess noise to timing imperfections. When the experimental imperfections are eliminated, we show that shot noise limit is attained by acquiring noise-free data in the same configuration as ACME II.

physics.atom-ph