A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.

physics.ins-det

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

nucl-ex

Search for the Neutron Electric Dipole Moment: Contributions from the Triangle Universities Nuclear Laboratory

A significant fraction of the research effort at the Triangle Universities Nuclear Laboratory (TUNL) focuses on weak interaction studies and searches for physics beyond the Standard Model. One major effort is the development of a new experimental technique to search for the neutron electric dipole moment (nEDM) that offers the potential for a factor of 100 increase in sensitivity over existing measurements. The search for this moment has the potential to reveal new sources of time reversal (T) and charge-conjugation-and-parity (CP) violation and to challenge calculations that propose extensions to the Standard Model. We provide a brief overview of the experiment as a whole and discuss the work underway at TUNL as part of this effort.

physics.ins-det

Measurements of the Total Cross Section for the Scattering of Polarized Neutrons from Polarized $^3$He

Measurements of polarized neutron--polarized $^3$He scattering are reported. The target consisted of cryogenically-polarized solid $^3$He, thickness 0.04 atom/b and polarization 40%. The longitudinal and transverse total cross-section differences $Δσ_L$ and $Δσ_T$ were measured for incident neutron energies 2-8 MeV. The results are compared to phase-shift predictions based on four different analyses of n-$^3$He scattering. The best agreement is obtained with a recent R-matrix analysis of A=4 scattering and reaction data, lending strong suport to the $^4$He level scheme obtained in that analysis.

nucl-ex

Test of Parity-Conserving Time-Reversal Invariance Using Polarized Neutrons and Nuclear Spin Aligned Holmium

A test of parity-conserving, time-reversal non-invariance (PC TRNI) has been performed in 5.9 MeV polarized neutron transmission through nuclear spin aligned holmium. The experiment searches for the T-violating five-fold correlation via a double modulation technique - flipping the neutron spin while rotating the alignment axis of the holmium. Relative cross sections for spin-up and spin-down neutrons are found to be equal to within $1.2 \times 10^{-5}$ (80\% confidence). This is a two order of magnitude improvement compared to traditional detailed balance studies of time reversal, and represents the most precise test of PC TRNI in a dynamical process.