SearcharxivSearch

arXiv subjects

D. G. Hitlin

Publications and source records attributed to D. G. Hitlin.

At least 19 recordsLinked to original sources

Model-independent extraction of form factors and $|V_{cb}|$ in $\overline{B} \rightarrow D \ell^- \overlineν_\ell$ with hadronic tagging at BaBar

Using the entire BaBar $Υ(4S)$ data set, the first two-dimensional unbinned angular analysis of the semileptonic decay $\overline{B} \rightarrow D \ell^- \overlineν_\ell$ is performed, employing hadronic reconstruction of the tag-side $B$ meson from $Υ(4S)\to B\overline{B}$. Here, $\ell$ denotes the light charged leptons $e$ and $μ$. A novel data-driven signal-background separation procedure with minimal dependence on simulation is developed. This procedure preserves all multi-dimensional correlations present in the data. The expected $\sin^2θ_\ell$ dependence of the differential decay rate in the Standard Model is demonstrated, where $θ_\ell$ is the lepton helicity angle. Including input from the latest lattice QCD calculations and previously available experimental data, the underlying form factors are extracted using both model-independent (BGL) and dependent (CLN) methods. Comparisons with lattice calculations show flavor SU(3) symmetry to be a good approximation in the $B_{(s)}\to D_{(s)}$ sector. Using the BGL results, the CKM matrix element $|V_{cb}|=(41.09\pm 1.16)\times 10^{-3}$ and the Standard Model prediction of the lepton-flavor universality violation variable $\mathcal{R}(D)=0.300\pm 0.004$, are extracted. The value of $|V_{cb}|$ from $\overline{B} \rightarrow D \ell^- \overlineν_\ell$ tends to be higher than that extracted using $\overline{B} \rightarrow D \ell^- \overlineν_\ell$. The Standard Model $\mathcal{R}(D)$ calculation is at a $1.97σ$ tension with the latest HFLAV experimental average.

hep-ex

Workshop on a future muon program at FNAL

The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e.g., muon collider). Topics included high-power targetry, status of R&D for Mu2e-II, development of compressor rings, FFA and concepts for muon experiments (conversion, decays, muonium and other opportunities) at AMF. This document summarizes the workshop discussions with a focus on future R&D tasks needed to realize these concepts.

hep-ex

Search for $B$ Mesogenesis at BABAR

A new mechanism has been proposed to simultaneously explain the presence of dark matter and the matter-antimatter asymmetry in the universe. This scenario predicts exotic $B$ meson decays into a baryon and a dark sector anti-baryon ($ψ_D$) with branching fractions accessible at $B$ factories. We present a search for $B \rightarrow Λψ_D$ decays using data collected by the $BABAR$ experiment at SLAC. This reaction is identified by fully reconstructing the accompanying $B$ meson and requiring the presence of a single $Λ$ baryon in the remaining particles. No significant signal is observed, and bounds on the $B \rightarrow Λψ_D$ branching fraction are derived in the range $0.13 - 5.2\times 10^{-5}$ for $1.0 < m_{ψ_D} < 4.2$ GeV/$c^{2}$. These results set strong constraints on the parameter space allowed by the theory.

hep-ex

Mu2e-II: Muon to electron conversion with PIP-II

An observation of Charged Lepton Flavor Violation (CLFV) would be unambiguous evidence for physics beyond the Standard Model. The Mu2e and COMET experiments, under construction, are designed to push the sensitivity to CLFV in the mu to e conversion process to unprecedented levels. Whether conversion is observed or not, there is a strong case to be made for further improving sensitivity, or for examining the process on additional target materials. Mu2e-II is a proposed upgrade to Mu2e, with at least an additional order of magnitude in sensitivity to the conversion rate over Mu2e. The approach and challenges for this proposal are summarized. Mu2e-II may be regarded as the next logical step in a continued high-intensity muon program at FNAL.

hep-ex

A New Charged Lepton Flavor Violation Program at Fermilab

The muon has played a central role in establishing the Standard Model of particle physics, and continues to provide valuable information about the nature of new physics. A new complex at Fermilab, the Advanced Muon Facility, would provide the world's most intense positive and negative muon beams by exploiting the full potential of PIP-II and the Booster upgrade. This facility would enable a broad muon physics program, including studies of charged lepton flavor violation, muonium-antimuonium transitions, a storage ring muon EDM experiment, and muon spin rotation experiments. This document describes a staged realization of this complex, together with a series of next-generation experiments to search for charged lepton flavor violation.

hep-ex

Measurements of the Absolute Branching Fractions of $B^\pm \to K^\pm X_{c\bar c}$

A study of the two body decays $B^\pm\rightarrow X_{c\bar c}K^\pm$, where X$_{c\bar c}$ refers to one charmonium state, is reported by BaBar collaboration using a data sample of 424 fb$^{-1}$. The absolute determination of branching fractions for these decays are significantly improved compared to previous BaBaR measurements. Evidence is found for the decay $B^+\rightarrow X(3872)K^+$ at the $3σ$ level. The absolute branching fraction ${\cal B}(B^+\rightarrow X(3872)K^+) = (2.1\pm0.6({\rm stat})\pm0.3({\rm syst}))\times 10^{-4}$ is measured for the first time. It follows that ${\cal B}(X(3872)\rightarrow J/ψπ^+π^-)=(4.1\pm1.3)\%$, supporting the hypothesis of a molecular component for this resonance.

hep-ex

Precision measurement of the ${\cal B}(Υ(3S)\toτ^+τ^-)/{\cal B}(Υ(3S)\toμ^+μ^-)$ ratio

We report on a precision measurement of the ratio ${\cal R}_{τμ}^{Υ(3S)} = {\cal B}(Υ(3S)\toτ^+τ^-)/{\cal B}(Υ(3S)\toμ^+μ^-)$ using data collected with the BaBar detector at the SLAC PEP-II $e^+e^-$ collider. The measurement is based on a 28 fb$^{-1}$ data sample collected at a center-of-mass energy of 10.355 GeV corresponding to a sample of 122 million $Υ(3S)$ mesons. The ratio is measured to be ${\cal R}_{τμ}^{Υ(3S)} = 0.966 \pm 0.008_\mathrm{stat} \pm 0.014_\mathrm{syst}$ and is in agreement with the Standard Model prediction of 0.9948 within 2 standard deviations. The uncertainty in ${\cal R}_{τμ}^{Υ(3S)}$ is almost an order of magnitude smaller than the only previous measurement.

hep-ex

Search for lepton-flavor violating decays $D^{0}\rightarrow X^{0}e^{\pm}μ^{\mp}$

We present a search for seven lepton-flavor-violating neutral charm decays of the type $D^{0}\rightarrow X^{0} e^{\pm} μ^{\mp}$, where $X^{0}$ represents a $π^{0}$, $K^{0}_{\rm S}$, $\bar{K^{*0}}$, $ρ^{0}$, $ϕ$, $ω$, or $η$ meson. The analysis is based on $468$ fb$^{-1}$ of $e^+e^-$ annihilation data collected at or close to the $Υ(4S)$ resonance with the BaBar detector at the SLAC National Accelerator Laboratory. No significant signals are observed, and we establish 90\% confidence level upper limits on the branching fractions in the range $(5.0 - 22.5)\times 10^{-7}$. The limits are between one and two orders of magnitude more stringent than previous measurements.

hep-ex

Search for rare or forbidden decays of the $D^{0}$ meson

We present a search for nine lepton-number-violating and three lepton-flavor-violating neutral charm decays of the type $D^0\rightarrow h^{\prime -} h^{-}\ell^{\prime +} \ell^{+}$ and $D^0\rightarrow h^{\prime -} h^{+}\ell^{\prime\pm} \ell^{\mp}$, where $h$ and $h^{\prime}$ represent a $K$ or $π$ meson and $\ell$ and $\ell^{\prime}$ an electron or muon. The analysis is based on $468$ fb$^{-1}$ of $e^+e^-$ annihilation data collected at or close to the $Y(4S)$ resonance with the BaBar detector at the SLAC National Accelerator Laboratory. No significant signal is observed for any of the twelve modes and we establish 90% confidence level upper limits on the branching fractions in the range $(1.0 - 30.6)\times 10^{-7}$. The limits are between one and three orders of magnitude times more stringent than previous measurements.

hep-ex

Search for $B^- \to Λ\bar p ν\barν$ with the BABAR experiment

We search for the rare flavor-changing neutral current process $B^- \to Λ{\overline p} ν{\overlineν}$ using data from the BABAR experiment. A total of 424 fb$^{-1}$ of $e^+e^-$ collision data collected at the center-of-mass energy of the $Υ$(4S) resonance is used in this study, corresponding to a sample of ${(471 \pm 3) \times 10^{6}}$ $B\overline{B}$ pairs. Signal $B^- \to Λ{\overline p} ν{\overlineν}$ candidates are identified by first fully reconstructing a $B^+$ decay in one of many possible exclusive decays to hadronic final states, then examining detector activity that is not associated with this reconstructed $B^+$ decay for evidence of a signal $B^- \to Λ{\overline p} ν{\overlineν}$ decay. The data yield is found to be consistent with the expected background contribution under a null signal hypothesis, resulting in an upper limit of ${{\cal B} (B^- \to Λ{\overline p} ν{\overlineν}) < 3.0\times 10^{-5}}$ at the $90\%$ confidence level.

hep-ex

Mu2e calorimeter readout system

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.

physics.ins-det

The Mu2e calorimeter: quality assurance of production crystals and SiPMs

The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.

physics.ins-det

The Mu2e undoped CsI crystal calorimeter

The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

physics.ins-det

Quality Assurance on Un-Doped CsI Crystals for the Mu2e Experiment

The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.

physics.ins-det

Design and status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.

physics.ins-det

Quality Assurance on a custom SiPMs array for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.

physics.ins-det

The calorimeter of the Mu2e experiment at Fermilab

The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10-4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.

physics.ins-det

Design and status of the Mu2e electromagnetic calorimeter

The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

physics.ins-det