SearcharxivSearch

arXiv subjects

D. Gorelov

Publications and source records attributed to D. Gorelov.

17 recordsLinked to original sources

Total absorption $γ$-ray spectroscopy of the $β$ decays of $^{96\text{gs,m}}$Y

The $β$ decays of the ground state (gs) and isomeric state (m) of $^{96}$Y have been studied with the total absorption $γ$-ray spectroscopy technique at the Ion Guide Isotope Separator On-Line facility. The separation of the 8$^{+}$ isomeric state from the 0$^{-}$ ground state was achieved thanks to the purification capabilities of the JYFLTRAP double Penning trap system. The $β$-intensity distributions of both decays have been independently determined. In the analyses the de-excitation of the 1581.6 keV level in $^{96}$Zr, in which conversion electron emission competes with pair production, has been carefully considered and found to have significant impact on the $β$-detector efficiency, influencing the $β$-intensity distribution obtained. Our results for $^{96\text{gs}}$Y (0$^+$) confirm the large ground state to ground state $β$-intensity probability, although a slightly larger value than reported in previous studies was obtained, amounting to $96.6_{-2.1}^{+0.3}\%$ of the total $β$ intensity. Given that the decay of $^{96\text{gs}}$Y is the second most important contributor to the reactor antineutrino spectrum between 5 and 7 MeV, the impact of the present results on reactor antineutrino summation calculations has been evaluated. In the decay of $^{96\text{m}}$Y (8$^{+}$), previously undetected $β$ intensity in transitions to states above 6 MeV has been observed. This shows the importance of total absorption $γ$-ray spectroscopy measurements of $β$ decays with highly fragmented de-excitation patterns. $^{96\text{m}}$Y (8$^{+}$) is a major contributor to reactor decay heat in uranium-plutonium and thorium-uranium fuels around 10 s after fission pulses, and the newly measured average $β$ and $γ$ energies differ significantly from the previous values in evaluated databases (...)

nucl-ex

Determination of Beta Decay Ground State Feeding of Nuclei of Importance for Reactor Applications

In $β$-decay studies the determination of the decay probability to the ground state of the daughter nucleus often suffers from large systematic errors. The difficulty of the measurement is related to the absence of associated delayed $γ$-ray emission. In this work we revisit the $4πγ-β$ method proposed by Greenwood and collaborators in the 1990s, which has the potential to overcome some of the experimental difficulties. Our interest is driven by the need to determine accurately the $β$-intensity distributions of fission products that contribute significantly to the reactor decay heat and to the antineutrinos emitted by reactors. A number of such decays have large ground state branches. The method is relevant for nuclear structure studies as well. Pertinent formulae are revised and extended to the special case of $β$-delayed neutron emitters, and the robustness of the method is demonstrated with synthetic data. We apply it to a number of measured decays that serve as test cases and discuss the features of the method. Finally, we obtain ground state feeding intensities with reduced uncertainty for four relevant decays that will allow future improvements in antineutrino spectrum and decay heat calculations using the summation method.

nucl-ex

Total absorption $γ$-ray spectroscopy of the $β$-delayed neutron emitters $^{137}$I and $^{95}$Rb

The decays of the $β$-delayed neutron emitters $^{137}$I and $^{95}$Rb have been studied with the total absorption $γ$-ray spectroscopy technique. The purity of the beams provided by the JYFLTRAP Penning trap at the ion guide isotope separator on-line facility in Jyväskylä allowed us to carry out a campaign of isotopically pure measurements with the decay total absorption $γ$-ray spectrometer, a segmented detector composed of eighteen NaI(Tl) modules. The contamination coming from the interaction of neutrons with the spectrometer has been carefully studied, and we have tested the use of time differences between prompt $γ$-rays and delayed neutron interactions to eliminate this source of contamination. Due to the sensitivity of our spectrometer, we have found a significant amount of $β$-intensity to states above the neutron separation energy that de-excite by $γ$-rays, comparable to the neutron emission probability. The competition between $γ$ de-excitation and neutron emission has been compared with Hauser-Feshbach calculations, and it can be understood as a nuclear structure effect. In addition, we have studied the impact of the $β$-intensity distributions determined in this work on reactor decay heat and reactor antineutrino spectrum summation calculations. The robustness of our results is demonstrated by a thorough study of uncertainties, and with the reproduction of the spectra of the individual modules and the module-multiplicity gated spectra. This work represents the state-of-the-art of our analysis methodology for segmented total absorption spectrometers.

nucl-ex

Total absorption $γ$-ray spectroscopy of niobium isomers

The $β$ intensity distributions of the decays of $^{100\text{gs},100\text{m}}$Nb and $^{102\text{gs},102\text{m}}$Nb have been determined using the Total Absorption $γ$-Ray Spectroscopy technique. The JYFLTRAP double Penning trap system was employed to disentangle the isomeric states involved, lying very close in energy, in a campaign of challenging measurements performed with the Decay Total Absorption $γ$-ray Spectrometer at the Ion Guide Isotope Separator On-Line facility in Jyväskylä. The low-spin isomeric state of each niobium case was populated through the decay of the zirconium parent, that was treated as a contaminant. We have applied a method to extract this contamination, and additionally we have obtained $β$ intensity distributions for these zirconium decays. The $β$-strength distributions evaluated with these results were compared with calculations in quasiparticle random-phase approximation, suggesting a prolate configuration for the ground states of $^{100,102}$Zr. The footprint of the Pandemonium effect was found when comparing our results for the analyses of the niobium isotopes with previous decay data. The $β$-intensities of the decay of $^{102\text{m}}$Nb were obtained for the first time. A careful evaluation of the uncertainties was carried out, and the consistency of our results was validated taking advantage of the segmentation of our spectrometer. The final results were used as input in reactor summation calculations. A large impact on antineutrino spectrum calculations was already reported and here we detail the significant impact on decay heat calculations.

nucl-ex

First determination of $β$-delayed multiple neutron emission beyond A = 100 through direct neutron measurement: The P$_{2n}$ value of $^{136}$Sb

Background: $β$-delayed multiple neutron emission has been observed for some nuclei with A$\leq$100, with $^{100}$Rb being the heaviest $β$2n emitter measured to date. So far, only 25 P$_{2n}$ values have been determined for the $\sim$300 nuclei that may decay in this way. Accordingly, it is of interest to measure P$_{2n}$ values for the other possible multiple neutron emitters throughout the chart of the nuclides. It is of particular interest to make such measurement for nuclei with A$>$100 to test the predictions of theoretical models and simulation tools for the decays of heavy nuclei in the region of very neutron-rich nuclei. In addition, the decay properties of these nuclei are fundamental for the understanding of astrophysical nucleosynthesis processes such as the $r$-process, and safety inputs for nuclear reactors. Purpose: To determine for the first time the two neutron branching ratio, P$_{2n}$ value, for $^{136}$Sb through a direct neutron measurement, and to provide precise P$_{1n}$ values for $^{136}$Sb and $^{136}$Te. Method: Pure beams were provided by the JYFLTRAP at the IGISOL facility of the University of Jyväskylä, Finland. The purified ions were implanted into a moving tape at the end of the beam line. The detection setup consisted of a plastic scintillator placed right behind the implantation point, and the BELEN detector, based on neutron counters embedded in a polyethylene matrix. The analysis was based on the study of the $β$- and neutron- growth-and-decay curves and the $β$-one-neutron and $β$-two-neutron time correlations. Results: The P$_{2n}$ value of $^{136}$Sb was found to be 0.14(3)\% and the measured P$_{1n}$ values for $^{136}$Sb and $^{136}$Te were found to be 32.2(15)\% and 1.47(6)\%, respectively. The measured P$_{2n}$ value is a factor 44 smaller than predicted by the FRDM+QRPA model used for $r$-process calculations.

nucl-ex

Characterization and performance of the DTAS detector

DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption γ-ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of \b{eta}-delayed neutron emitting nuclei.

physics.ins-det

Study of the $β$-decay of $^{100}$Tc with Total Absorption $γ$-Ray Spectroscopy

The \b{eta}-decay of 100 Tc has been studied using the Total Absorption γ-Ray Spectroscopy technique at IGISOL. In this work the new DTAS spectrometer in coincidence with a cylindrical plastic \b{eta} detector has been employed. The \b{eta}-intensity to the ground state obtained from the analysis is in good agreement with previous high-resolution measurements. However, differences in the feeding to the first excited state as well as weak feeding to a new level at high excitation energy have been deduced from this experiment. Theoretical calculations performed in the quasiparticle random- phase approximation (QRPA) framework are also reported. Comparison of these calculations with our measurement serves as a benchmark for calculations of the double \b{eta}-decay of 100 Mo.

nucl-ex

Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons

In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic \b{eta}-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimental spectra. Moreover, taking into account the computational effort associated with this kind of simulation, we develop a method to convert the simulations of energy deposited into light collected, depending only on the interaction point in the detector. This method represents a useful solution when extensive simulations have to be done, as in the case of the calculation of the response function of the spectrometer in a total absorption γ-ray spectroscopy analysis.

physics.ins-det

Coulomb displacement energies as a probe for nucleon pairing in the $f_{7/2}$ shell

Coulomb displacement energies of $T=1/2$ mirror nuclei have been studied via a series of high-precision $Q_\mathrm{EC}$-value measurements with the double Penning trap mass spectrometer JYFLTRAP. Most recently, the $Q_\mathrm{EC}$ values of the $f_{7/2}$-shell mirror nuclei $^{45}$V ($Q_\mathrm{EC}=7123.82(22)$ keV) and $^{49}$Mn ($Q_\mathrm{EC}=7712.42(24)$ keV) have been measured with an unprecedented precision. The data reveal a 16-keV ($1.6σ$) offset in the adopted Atomic Mass Evaluation 2012 value of $^{49}$Mn suggesting the need for further measurements to verify the breakdown of the quadratic form of the isobaric multiplet mass equation. Precisely measured $Q_\mathrm{EC}$ values confirm that the pairing effect in the Coulomb energies is quenched when entering the $f_{7/2}$ shell and reaches a minimum in the midshell.

nucl-ex

Design of a High Intensity Neutron Source for Neutron-Induced Fission Yield Studies

The upgraded IGISOL facility with JYFLTRAP, at the accelerator laboratory of the University of Jyväskylä, has been supplied with a new cyclotron which will provide protons of the order of 100 μA with up to 30 MeV energy, or deuterons with half the energy and intensity. This makes it an ideal place for measurements of neutron-induced fission products from various actinides, in view of proposed future nuclear fuel cycles. The groups at Uppsala University and University of Jyväskylä are working on the design of a neutron converter that will be used as neutron source in fission yield studies. The design is based on simulations with Monte Carlo codes and a benchmark measurement that was recently performed at The Svedberg Laboratory in Uppsala. In order to obtain a competitive count rate the fission targets will be placed very close to the neutron converter. The goal is to have a flexible design that will enable the use of neutron fields with different energy distributions. In the present paper, some considerations for the design of the neutron converter will be discussed, together with different scenarios for which fission targets and neutron energies to focus on.

nucl-ex

Accurate fission data for nuclear safety

The Accurate fission data for nuclear safety (AlFONS) project aims at high precision measurements of fission yields, using the renewed IGISOL mass separator facility in combination with a new high current light ion cyclotron at the University of Jyvaskyla. The 30 MeV proton beam will be used to create fast and thermal neutron spectra for the study of neutron induced fission yields. Thanks to a series of mass separating elements, culminating with the JYFLTRAP Penning trap, it is possible to achieve a mass resolving power in the order of a few hundred thousands. In this paper we present the experimental setup and the design of a neutron converter target for IGISOL. The goal is to have a flexible design. For studies of exotic nuclei far from stability a high neutron flux (10^12 neutrons/s) at energies 1 - 30 MeV is desired while for reactor applications neutron spectra that resembles those of thermal and fast nuclear reactors are preferred. It is also desirable to be able to produce (semi-)monoenergetic neutrons for benchmarking and to study the energy dependence of fission yields. The scientific program is extensive and is planed to start in 2013 with a measurement of isomeric yield ratios of proton induced fission in uranium. This will be followed by studies of independent yields of thermal and fast neutron induced fission of various actinides.

nucl-ex

Characterization of a Be(p,xn) neutron source for fission yields measurements

We report on measurements performed at The Svedberg Laboratory (TSL) to characterize a proton-neutron converter for independent fission yield studies at the IGISOL-JYFLTRAP facility (Jyväskylä, Finland). A 30 MeV proton beam impinged on a 5 mm water-cooled Beryllium target. Two independent experimental techniques have been used to measure the neutron spectrum: a Time of Flight (TOF) system used to estimate the high-energy contribution, and a Bonner Sphere Spectrometer able to provide precise results from thermal energies up to 20 MeV. An overlap between the energy regions covered by the two systems will permit a cross-check of the results from the different techniques. In this paper, the measurement and analysis techniques will be presented together with some preliminary results.

physics.ins-det

Isomeric states close to doubly magic $^{132}$Sn studied with JYFLTRAP

The double Penning trap mass spectrometer JYFLTRAP has been employed to measure masses and excitation energies for $11/2^-$ isomers in $^{121}$Cd, $^{123}$Cd, $^{125}$Cd and $^{133}$Te, for $1/2^-$ isomers in $^{129}$In and $^{131}$In, and for $7^-$ isomers in $^{130}$Sn and $^{134}$Sb. These first direct mass measurements of the Cd and In isomers reveal deviations to the excitation energies based on results from beta-decay experiments and yield new information on neutron- and proton-hole states close to $^{132}$Sn. A new excitation energy of 144(4) keV has been determined for $^{123}$Cd$^m$. A good agreement with the precisely known excitation energies of $^{121}$Cd$^m$, $^{130}$Sn$^m$, and $^{134}$Sb$^m$ has been found.

nucl-ex

Precision Mass Measurements beyond $^{132}$Sn: Anomalous behaviour of odd-even staggering of binding energies

Atomic masses of the neutron-rich isotopes $^{121-128}$Cd, $^{129,131}$In, $^{130-135}$Sn, $^{131-136}$Sb, and $^{132-140}$Te have been measured with high precision (10 ppb) using the Penning trap mass spectrometer JYFLTRAP. Among these, the masses of four r-process nuclei $^{135}$Sn, $^{136}$Sb, and $^{139,140}$Te were measured for the first time. The data reveals a strong $N$=82 shell gap at $Z$=50 but indicates the importance of correlations for $Z>50$. An empirical neutron pairing gap expressed as the odd-even staggering of isotopic masses shows a strong quenching across $N$=82 for Sn, with the $Z$-dependence that is unexplainable by the current theoretical models.

nucl-ex

Q_EC values of the Superallowed beta-Emitters 10-C, 34-Ar, 38-Ca and 46-V

The Q_EC values of the superallowed beta+ emitters 10-C, 34-Ar, 38-Ca and 46-V have been measured with a Penning-trap mass spectrometer to be 3648.12(8), 6061.83(8), 6612.12(7) and 7052.44(10) keV, respectively. All four values are substantially improved in precision over previous results.

nucl-ex

Mass measurements in the vicinity of the doubly-magic waiting point 56Ni

Masses of 56,57Fe, 53Co^m, 53,56Co, 55,56,57Ni, 57,58Cu, and 59,60Zn have been determined with the JYFLTRAP Penning trap mass spectrometer at IGISOL with a precision of dm/m \le 3 x 10^{-8}. The QEC values for 53Co, 55Ni, 56Ni, 57Cu, 58Cu, and 59Zn have been measured directly with a typical precision of better than 0.7 keV and Coulomb displacement energies have been determined. The Q values for proton captures on 55Co, 56Ni, 58Cu, and 59Cu have been measured directly. The precision of the proton-capture Q value for 56Ni(p,gamma)57Cu, Q(p,gamma) = 689.69(51) keV, crucial for astrophysical rp-process calculations, has been improved by a factor of 37. The excitation energy of the proton emitting spin-gap isomer 53Co^m has been measured precisely, Ex = 3174.3(10) keV, and a Coulomb energy difference of 133.9(10) keV for the 19/2- state has been obtained. Except for 53Co, the mass values have been adjusted within a network of 17 frequency ratio measurements between 13 nuclides which allowed also a determination of the reference masses 55Co, 58Ni, and 59Cu.

nucl-ex

Analysis of a Cyclotron Based 400 MeV/u Driver System for a Radioactive Beam Facility

The creation of intense radioactive beams requires intense and energetic primary beams. A task force analysis of this subject recommended an acceleration system capable of 400 MeV/u uranium at 1 particle uA as an appropriate driver for such a facility. The driver system should be capable of accelerating lighter ions at higher intensity such that a constant final beam power (~100kW) is maintained. This document is a more detailed follow on to the previous analysis of such a system incorporating a cyclotron. The proposed driver pre-acceleration system consists of an ion source, radio frequency quadrupole, and linac chain capable of producing a final energy of 30 MeV/u and a charge (Q) to mass (A) of Q/A ~1/3. This acceleration system would be followed by a Separated Sector Cyclotron with a final output energy of 400 MeV/u. This system provides a more cost-effective solution in terms of initial capital investment as well as of operation compared to a fully linac system with the same primary beam output parameters.

nucl-ex