SearcharxivSearch

arXiv subjects

D. H. Dongwi

Publications and source records attributed to D. H. Dongwi.

9 recordsLinked to original sources

The DarkLight Experiment at TRIUMF

This paper reports on the commissioning of the DarkLight experiment at the ARIEL superconducting electron linear accelerator located at TRIUMF in Vancouver, Canada. DarkLight was designed to utilize the ARIEL electron beam to search for a new boson, $A^\prime$, which preferentially couples to leptons, with a mass in the range 13-17 MeV/$c^2$. Such a boson could be produced via the $e^-~X\rightarrow e^-~X~A^\prime$ process, and the resulting $A^\prime\rightarrow e^+~e^-$ decay used to reconstruct the invariant mass of the $A^\prime$. The $e^+e^-$ pair is detected using a pair of magnetic spectrometers. Each spectrometer is instrumented with two triple GEM detectors and a scintillating strip hodoscope to trigger the event readout. Electron beam energies between 10 and 30 MeV were used to commission the experiment with a 1$~μ$m thick carbon target. With both spectrometer polarities set to select electrons, elastic and Møller scattering were used to examine detector performance and compare with predicted distributions from Monte Carlo simulations. Planned upgrades to the e-linac will allow searches to be made with beam energies up to 50 MeV using a 1$~μ$m thick tantalum target.

physics.ins-det

Hybrid Machine-Learning Particle Identification for the ePIC Proximity-Focusing RICH

We present a machine-learning-based particle-identification study for the proximity-focusing Ring Imaging Cherenkov (pfRICH) detector of the ePIC experiment at the Electron-Ion Collider. Operating in the backward region ($-3.5 \lesssim η\lesssim -1.5$), the pfRICH is designed to achieve at least $3σ$ separation among pions, kaons, and protons up to $7,\mathrm{GeV}/c$ for Semi-Inclusive Deep Inelastic Scattering measurements. Using a standalone Geant4 simulation of the pfRICH, we develop a hybrid machine-learning approach that combines convolutional neural-network-based feature extraction with gradient-boosted decision-tree classifiers. This method significantly enhances Cherenkov-ring pattern recognition and improves particle-separation performance, demonstrating the effectiveness of hybrid machine-learning techniques for next-generation Cherenkov detectors at the EIC.

physics.ins-det

The SHMS 11 GeV/c Spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/c, the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5 to 40 degrees, thus allowing a wide range of low cross-section experiments to be conducted. These experiments complement and extend the previous Hall C research program to higher energies.

physics.ins-det

Remeasurement of the $^{239}$Pu(n,f)/$^{235}$U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber Using Vapor-deposited Targets

The NIFFTE fission Time Projection Chamber (fissionTPC) has been used to measure the $^{239}$Pu(n,f)/$^{235}$U(n,f) cross-section ratio for neutron-induced fission in the range of 0.1 - 100 MeV, with high precision. A white neutron source was provided by the Los Alamos Neutron Science Center, where the experiment was conducted as a remeasurement to evaluate a roughly 2% discrepancy of the previous fissionTPC results with ENDF/B-VIII.0. A detailed accounting of measurement uncertainties was performed, based on the fissionTPC's novel ability to provide three-dimensional reconstruction of fission-fragment ionization profiles. Current results obtained using a vapor-deposited, highly uniform $^{239}$Pu target, in comparison to the measurement published in 2021, where a $^{239}$Pu electroplated target was used, are presented and discussed. The remeasurement presented here is in agreement with the previous fissionTPC result within measurement uncertainties.

nucl-ex

New determination of the branching ratio of the structure dependent radiative $K^{+} \to e^{+} ν_{e} γ$ decay

The branching ratio of the structure dependent (SD) radiative $K^{+} \to e^{+} ν_{e} γ$ decay relative to that of the $K^+\rightarrow e^+ ν_{e} (γ)$ decay including the internal bremsstrahlung (IB) process ($K_{e2(γ)}$) has been measured in the J-PARC E36 experiment using plastic scintillator/lead sandwich detectors. In the analysis, the effect of IB was also taken into account in the SD radiative decay as $K_{e2γ(γ)}^{\rm SD}$. By combining the new data with the previously reported result of the E36 experiment using a CsI(Tl) calorimeter after revision for the IB correction for $K_{e2γ(γ)}^{\rm SD}$, a new value $Br(K_{e2γ(γ)}^{\rm SD})/Br(K_{e2(γ)})=1.20\pm0.07$ has been determined, which is consistent with a recent lattice QCD calculation, but larger than the expectation of Chiral Perturbation Theory (ChPT) at order $O(p^4)$ and the previous KLOE value. Also, using the method to relate form factor and branching ratio described in the KLOE paper, the present result is consistent with the form factor prediction based on a gauged nonlocal chiral quark model, but larger than ChPT at order $O(p^6)$.

hep-ex

Searching for New Physics with DarkLight at the ARIEL Electron-Linac

The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the $^8$Be and $^4$He anomaly, which could be explained by a new fifth force carrier with a mass of 17 MeV/$c^2$. The proposed DarkLight experiment would search for this potential low mass force carrier at ARIEL in the 10-20 MeV e$^+$e$^-$ invariant mass range. This proceeding will focus on the experimental design and physics case of the DarkLight experiment.

nucl-ex

Measurement of structure dependent radiative $K^{+} \rightarrow e^{+} νγ$ decays using stopped positive kaons

The structure dependent radiative $K^+ \rightarrow e^+ νγ$ ($K_{e2γ}^{\rm SD^+}$) decay was investigated with stopped positive kaons. The $e^+$ momentum spectra containing 574$\pm$30 $K_{e2γ}^{\rm SD^+}$ events with a $K^+ \rightarrow μ^+ ν$ ($K_{\mu2}$) background of 28$\pm$19 events were measured with and without a photon in coincidence and analyzed with Monte Carlo simulations for acceptance and detector response to extract the ratio of the branching ratio of the $K_{e2γ}^{\rm SD^+}$ decay and the $K^+ \rightarrow e^+ ν$ decay including the internal bremsstrahlung process ($K_{e2(γ)}$). A value of $Br(K_{e2γ}^{\rm SD^+}) / Br(K_{e2(γ)}) = 1.12\pm0.07_{\rm stat} \pm 0.04_{\rm syst}$ was obtained. This indicates a partial branching ratio, $Br(K_{e2γ}^{\rm SD^+}, ~{p_e>200~{\rm MeV}/c}, ~{E_γ>10~{\rm MeV}})/Br(K_{\mu2}) =(1.85 \pm 0.11_{\rm{stat}} \pm 0.07_{\rm{syst}}) \times10^{-5}$, which is $25\%(\sim$2.5$σ)$ higher than the previous experimental result.

hep-ex

Measurement of material isotopics and atom number ratio with alpha-particle spectroscopy for the NIFFTE fission Time Projection Chamber actinide target

We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is intended to provide an absolute normalization of the measured fission cross-section ratio. The Pu-239/U-235 atom number ratio was measured with a combination of mass spectrometry and alpha-spectroscopy with a planar silicon detector with uncertainties of less than 1%.

nucl-ex

Measurement of the $^{239}$Pu(n,f)/$^{235}$U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber

The $^{239}$Pu(n,f)/$^{235}$U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provides a pulsed white source of neutrons. The data are recommended to be used as a cross-section ratio shape. A discussion of the status of the absolute normalization and comparisons to ENDF evaluations and previous measurements is included.

nucl-ex