SearcharxivSearch

arXiv subjects

D. Henaff

Publications and source records attributed to D. Henaff.

9 recordsLinked to original sources

Performance of the High-Angle Time Projection Chambers in the Upgraded T2K Off-Axis Near Detector

The off-axis magnetic near detector of the T2K experiment has undergone a significant upgrade, including the construction and installation of two new Time Projection Chambers featuring innovative resistive Micromegas technology and a field cage composed of thin composite walls. This paper provides a detailed description of the new components of the chambers, including the gas system, gas monitoring chambers, and data acquisition system. Additionally, it reports the results of extensive testing using both neutrino beams and cosmic rays, with comparisons between data and Monte Carlo simulations. The new detectors achieve improved spatial resolution and enhanced particle identification capabilities which are crucial for the precision goals of the T2K experiment.

physics.ins-det

First measurement of neutron capture multiplicity in neutrino-oxygen neutral-current quasi-elastic-like interactions using an accelerator neutrino beam

We report the first measurement of neutron capture multiplicity in neutrino-oxygen neutral-current quasi-elastic-like interactions at the gadolinium-loaded Super-Kamiokande detector using the T2K neutrino beam, which has a peak energy of about 0.6 GeV. A total of 30 neutral-current quasi-elastic-like event candidates were selected from T2K data corresponding to an exposure of $1.76\times10^{20}$ protons on target. The $\gamma$ ray signals resulting from neutron captures were identified using a neural network. The flux-averaged mean neutron capture multiplicity was measured to be $1.37\pm0.33\text{ (stat.)}$$^{+0.17}_{-0.27}\text{ (syst.)}$, which is compatible within $2.3\,\sigma$ than predictions obtained using our nominal simulation. We discuss potential sources of systematic uncertainty in the prediction and demonstrate that a significant portion of this discrepancy arises from the modeling of hadron-nucleus interactions in the detector medium.

hep-ex

Characterization of the Electronic Noise in the Readout of Resistive Micromegas in the High-Angle Time Projection Chambers of the T2K Experiment

The two high-angle Time Projection Chambers of the T2K experiment are equipped with a new readout system based on resistive Micromegas detector technology, and utilize custom-made electronics based on AFTER chips for signal processing. This study analyzes and characterizes the electronic noise of the detector readout chain to develop a comprehensive noise model. The model enables the generation of Monte Carlo simulations to investigate systematic effects in signal processing. The analysis is based on data collected from 32 resistive Micromegas detectors, recorded without zero suppression. All detectors exhibit a quasi-identical and time-stable noise level. The developed analytical model accurately describes the observed noise, and derived Monte Carlo simulations show excellent agreement with experimental data.

physics.ins-det

Search for Very-Short-Baseline Oscillations of Reactor Antineutrinos with the SoLid Detector

In this letter we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, PVT and 6LiF:ZnS(Ag), to measure antineutrinos via their inverse-beta-decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12800 voxels and operates over a very short 6.3--8.9 m baseline from the reactor core. The detector segmentation and its 3D imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilised for signal-background discrimination. We present a result based on 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data-taking. A total of 29479 $\pm$ 603 (stat.) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the Reactor Antineutrino Anomaly.

hep-ex

Analysis of test beam data taken with a prototype of TPC with resistive Micromegas for the T2K Near Detector upgrade

In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection of the charge emitted by ionization electrons over several pads, improving the determination of the track position. The TPC prototype has been equipped with the first ERAM module produced for T2K and with the HA-TPC readout electronics chain and it has been exposed to the DESY Test Beam in order to measure spatial and dE/dx resolution. In this paper we characterize the performances of the ERAM and, for the first time, we compare them with a newly developed simulation of the detector response. Spatial resolution better than 800 ${\mu \rm m}$ and dE/dx resolution better than 10% are observed for all the incident angles and for all the drift distances of interest. All the main features of the data are correctly reproduced by the simulation and these performances fully fulfill the requirements for the HA-TPCs of T2K.

physics.ins-det

SoLid: A short baseline reactor neutrino experiment

The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino energy spectrum and flux and to search for very short distance neutrino oscillations as a probe of eV-scale sterile neutrinos. This paper describes the SoLid detection principle, the mechanical design and the construction of the detector. It then reports on the installation and commissioning on site near the BR2 reactor, Belgium, and finally highlights its performance in terms of detector response and calibration.

physics.ins-det

Commissioning and Operation of the Readout System for the SoLid Neutrino Detector

The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order to identify these interactions. A novel detector design has been developed using 12800 5 cm cubes for high segmentation. Each cube is formed of a sandwich of two scintillators, PVT and 6LiF:ZnS(Ag), allowing the detection and identification of positrons and neutrons respectively. The active volume of the detector is an array of cubes measuring 80x80x250 cm (corresponding to a fiducial mass of 1.6 T), which is read out in layers using two dimensional arrays of wavelength shifting fibres and silicon photomultipliers, for a total of 3200 readout channels. Signals are recorded with 14 bit resolution, and at 40 MHz sampling frequency, for a total raw data rate of over 2 Tbit/s. In this paper, we describe a novel readout and trigger system built for the experiment, that satisfies requirements on: compactness, low power, high performance, and very low cost per channel. The system uses a combination of high price-performance FPGAs with a gigabit Ethernet based readout system, and its total power consumption is under 1 kW. The use of zero suppression techniques, combined with pulse shape discrimination trigger algorithms to detect neutrons, results in an online data reduction factor of around 10000. The neutron trigger is combined with a large per-channel history time buffer, allowing for unbiased positron detection. The system was commissioned in late 2017, with successful physics data taking established in early 2018.

physics.ins-det

Development of a Quality Assurance Process for the SoLid Experiment

The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sheets on two faces of each cube, facilitate reconstruction of the neutrino signals. % The polyvinyltoluene scintillator is used as an $\overlineν_e$ target for the inverse beta decay of ($\overlineν_e + p \rightarrow e^{+}+n$), with the $^6$LiF:ZnS(Ag) sheets used for associated neutron detection. Scintillation signals are read out by a network of wavelength shifting fibres connected to multipixel photon counters. Whilst the high granularity provides a powerful toolset to discriminate backgrounds; by itself the segmentation also represents a challenge in terms of homogeneity and calibration, for a consistent detector response. The search for this light sterile neutrino implies a sensitivity to distortions of around $\mathcal{O}$(10)\% in the energy spectrum of reactor $\overlineν_e$. Hence, a very good neutron detection efficiency, light yield and homogeneous detector response are critical for data validation. The minimal requirements for the SoLid physics program are a light yield and a neutron detection efficiency larger than 40 PA/MeV/cube and 50 \% respectively. In order to guarantee these minimal requirements, the collaboration developed a rigorous quality assurance process for all 12800 cubic cells of the detector. To carry out the quality assurance process, an automated calibration system called CALIPSO was designed and constructed.

physics.ins-det

Optimisation of the scintillation light collection and uniformity for the SoLid experiment

This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile neutrino oscillation signatures in the anti-neutrino energy spectrum as a function of the distance to the core and energy. Performing a precise search requires high light yield of the scintillating elements and uniformity of the response in the detector volume. The SoLid experiment uses an innovative hybrid technology with two different scintillators: polyvinyltoluene scintillator cubes and $^6$LiF:ZnS(Ag) screens. A precision test bench based on a $^{207}$Bi calibration source has been developed to study improvements on the energy resolution and uniformity of the prompt scintillation signal of antineutrino interactions. A trigger system selecting the 1~MeV conversion electrons provides a Gaussian energy peak and allows for precise comparisons of the different detector configurations that were considered to improve the SoLid detector light collection. The light collection efficiency is influenced by the choice of wrapping material, the position of the $^6$LiF:ZnS(Ag) screen, the type of fibre, the number of optical fibres and the type of mirror at the end of the fibre. This study shows that large gains in light collection efficiency are possible compared to the SoLid SM1 prototype. The light yield for the SoLid detector is expected to be at least 52$\pm$2 photo-avalanches per MeV per cube, with a relative non-uniformity of 6 %, demonstrating that the required energy resolution of at least 14 % at 1 MeV can be achieved.

physics.ins-det