SearcharxivSearch

arXiv subjects

D. L. Rubin

Publications and source records attributed to D. L. Rubin.

8 recordsLinked to original sources

Simulation of the transit-time optical stochastic cooling process in the Cornell Electron Storage Ring

In preparation for a demonstration of optical stochastic cooling in the Cornell Electron Storage Ring (CESR) we have developed a particle tracking simulation to study the relevant beam dynamics. Optical radiation emitted in the pickup undulator gives a momentum kick to that same particle in the kicker undulator. The optics of the electron bypass from pickup to kicker couples betatron amplitude and momentum offset to path length so that the momentum kick reduces emittance and momentum spread. Nearby electrons contribute an incoherent noise. Layout of the bypass line is presented that accommodates optics with a range of transverse and longitudinal cooling parameters. The simulation is used to determine cooling rates and their dependence on bunch and lattice parameters for bypass optics with distinct emittance and momentum acceptance.

physics.acc-ph

Optical Stochastic Cooling with an Arc-Bypass in CESR

A proposed experiment to demonstrate Optical Stochastic Cooling (OSC) in the Cornell Electron Storage Ring (CESR) based on an arc-bypass design is presented. This arc-bypass provides significantly longer optical delay than the dog-leg style chicane, opening up the possibility of a multi-pass or staged optical amplifier that can achieve the gains required for effective cooling of hadron or heavy-ions. Beyond introducing the arc-bypass, in this paper we study the stability requirements for the dipoles comprising it and investigate the use of an optical feedback system to relax the dipole and light-path stability tolerances.

physics.acc-ph

A limit on the anisotropy of the one-way maximum attainable speed of the electron

We report here the first experimental result for the anisotropy of the one-way maximum attainable speed of the electron, $\vec{Δc_{1,e}}$, obtained via the study of a sidereal time dependence of a difference between the electron and positron beam momenta in the CESR storage ring at Cornell University. At 95 percent confidence, an upper limit for the component of $Δ\vec {c}_{1,e}/c$ perpendicular to Earth's rotational axis is found to be $5.5 \times 10^{-15}$.

hep-ex

Accelerator Design for the CHESS-U Upgrade

During the summer and fall of 2018 the Cornell High Energy Synchrotron Source (CHESS) is undergoing an upgrade to increase high-energy flux for x-ray users. The upgrade requires replacing one-sixth of the Cornell Electron Storage Ring (CESR), inverting the polarity of half of the CHESS beam lines, and switching to single-beam on-axis operation. The new sextant is comprised of six double-bend achromats (DBAs) with combined-function dipole-quadrupoles. Although the DBA design is widely utilized and well understood, the constraints for the CESR modifications make the CHESS-U lattice unique. This paper describes the design objectives, constraints, and implementation for the CESR accelerator upgrade for CHESS-U.

physics.acc-ph

Operation of the CESR-TA vertical beam size monitor at $E_{\rm b}$=4 GeV

We describe operation of the CESR-TA vertical beam size monitor (xBSM) with $e^\pm$ beams with $E_{\rm b}$=4 GeV. The xBSM measures vertical beam size by imaging synchrotron radiation x-rays through an optical element onto a detector array of 32 InGaAs photodiodes with 50 $μ$m pitch. The device has previously been successfully used to measure vertical beam sizes of 10-100 $μ$m on a bunch-by-bunch, turn-by-turn basis at $e^\pm$ beam energies of $\sim$2 GeV and source magnetic fields below 2.8 kG, for which the detector required calibration for incident x-rays of 1-5 keV. At $E_{\rm b}=4.0$ GeV and $B$=4.5 kG, however, the incident synchrotron radiation spectrum extends to $\sim$20 keV, requiring calibration of detector response in that regime. Such a calibration is described and then used to analyze data taken with several different thicknesses of filters in front of the detector. We obtain a relative precision of better than 4% on beam size measurement from 15-100 $μ$m over several different ranges of x-ray energy, including both 1-12 keV and 6-17 keV. The response of an identical detector, but tilted vertically by 60$^\circ$ in order to increase magnfication without a longer beamline, is measured and shown to improve x-ray detection above 4 keV without compromising sensitivity to beam size. We also investigate operation of a coded aperture using gold masking backed by synthetic diamond.

physics.acc-ph

Design and performance of coded aperture optical elements for the CESR-TA x-ray beam size monitor

We describe the design and performance of optical elements for an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2-5~$GeV. X-rays produced by a hard-bend magnet pass through a single- or multiple-slit (coded aperture) optical element onto a detector. The coded aperture slit pattern and thickness of masking material forming that pattern can both be tuned for optimal resolving power. We describe several such optical elements and show how well predictions of simple models track measured performances.

physics.ins-det

Visible-light beam size monitors using synchrotron radiation at CESR

A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the horizontal and vertical beam sizes over a wide range of beam currents. By varying the separation of the slits, beam sizes ranging from 50 to 500 um can be measured with a resolution of approximately 5 um. To measure larger beam size (> 500 um), direct imaging can be employed by rotating the double slits away from SR beam path. By imaging the pi-polarized component of SR, a small vertical beam size (~70 um) was measured during an undulator test run in CESR, which was consistent with the interferometer measurement. To measure the bunch length, a beam splitter is inserted to direct a fraction of light into a streak camera setup. This beam size monitor measures the transverse and longitudinal beam sizes simultaneously, which is successfully used for intrabeam scattering studies. Detailed error analysis is discussed.

physics.acc-ph

Vertical beam size measurement in the CESR-TA $e^+e^-$ storage ring using x-rays from synchrotron radiation

We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~μ$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2~$GeV. At such beam energies the xBSM images x-rays of $ε\approx$1-10$~$keV ($λ\approx 0.1-1$ nm) that emerge from a hard-bend magnet through a single- or multiple-slit (coded aperture) optical element onto an array of 32 InGaAs photodiodes with 50$~μ$m pitch. Beamlines and detectors are entirely in-vacuum, enabling single-shot beam size measurement down to below 0.1$~$mA ($2.5\times10^9$ particles) per bunch and inter-bunch spacing of as little as 4$~$ns. At $E_{\rm b}=2.1 $GeV, systematic precision of $\sim 1~μ$m is achieved for a beam size of $\sim12~μ$m; this is expected to scale as $\propto 1/σ_{\rm b}$ and $\propto 1/E_{\rm b}$. Achieving this precision requires comprehensive alignment and calibration of the detector, optical elements, and x-ray beam. Data from the xBSM have been used to extract characteristics of beam oscillations on long and short timescales, and to make detailed studies of low-emittance tuning, intra-beam scattering, electron cloud effects, and multi-bunch instabilities.

physics.ins-det