SearcharxivSearch

arXiv subjects

D. L. Zhang

Publications and source records attributed to D. L. Zhang.

15 recordsLinked to original sources

The First GECAM Observation Results on Terrestrial Gamma-ray Flashes and Terrestrial Electron Beams

Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is a space-borne instrument dedicated to monitoring high-energy transients, including Terrestrial Gamma-ray Flashes (TGFs) and Terrestrial Electron Beams (TEBs). We implemented a TGF/TEB search algorithm for GECAM, with which 147 bright TGFs, 2 typical TEBs and 2 special TEB-like events are identified during an effective observation time of $\sim$9 months. We show that, with gamma-ray and charged particle detectors, GECAM can effectively identify and distinguish TGFs and TEBs, and measure their temporal and spectral properties in detail. A very high TGF-lightning association rate of $\sim$80\% is obtained between GECAM and GLD360 in east Asia region.

astro-ph.HE

The Design and Performance of Charged Particle Detector onboard the GECAM Mission

The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is used to measure charged particles in the space environment, monitor energy and flow intensity changes, and identify between gamma-ray bursts and space charged particle events in conjunction with GRD. CPD uses plastic scintillator as the sensitive material for detection, silicon photomultiplier (SiPM) array as the optically readable device, and the inlaid Am-241 radioactive source as the onboard calibration means. In this paper, we will present the working principle, physical design, functional implementation and preliminary performance test results of the CPD.

astro-ph.IM

Quality assurance test and Failure Analysis of SiPM Arrays of GECAM Satellites

The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detector which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts and charged particle bursts. The GRD makes use of lanthanum bromide (LaBr3) crystal readout by SiPM. As the all available SiPM devices belong to commercial grade, quality assurance tests need to be performed in accordance with the aerospace specifications. In this paper, we present the results of quality assurance tests, especially a detailed mechanism analysis of failed devices during the development of GECAM. This paper also summarizes the application experience of commercial-grade SiPM devices in aerospace payloads, and provides suggestions for forthcoming SiPM space applications.

physics.ins-det

Dedicated SiPM array for GRD of GECAM

The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy. With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts, the gravitational wave high-energy electromagnetic counterpart all-sky monitor (GECAM) possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of gravitational waves and in subsequent observations.

hep-ex

Inflight performance of the GECAM Gamma-ray and Charge particle Detectors

The GECAM mission consists of two identical microsatellites (GECAM-A and GECAM-B). Each satellite is equipped with 25 gamma-ray detectors (GRD) and 8 charged particle detectors (CPD). The main scientific objective of the GECAM mission is to detect gamma-ray bursts (GRBs) associated with the gravitational wave events produced by the merging of binary compact stars. After the launch on Dec. 10, 2020 , we carried out a series of on orbit tests. This paper introduces the test results of the GECAM-B satellite. According to the in-flight performance, the energy band for gamma-ray detection of GECAM-B is from about 7 keV to 3.5 MeV. GECAM-B can achieve prompt localization of GRBs. For the first time, GECAM-B realized a quasi-real-time transmission of trigger information using Beidou-3 RDSS. Keywords GECAM, gamma-ray burst, gravitational wave, GRD, CPD

physics.ins-det

The SiPM Array Data Acquisition Algorithm Applied to the GECAM Satellite Payload

The Gravitational Wave Burst High-energy Electromagnetic Counterpart All-sky Monitor (GECAM), consists of 2 small satellites that each contain 25 LaBr3 (lanthanum bromide doped with cerium chloride) detectors and 8 plastic scintillator detectors. The detector signals are read out using a silicon photomultiplier (SiPM) array. In this study, an acquisition algorithm for in-orbit real-time SiPM array data is designed and implemented, and the output event packet is defined. Finally, the algorithm's efficacy for event acquisition is verified.

astro-ph.IM

Ground-based calibration and characterization of GRD of GECAM: 8-160 keV

As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy band (>160 keV) with radioactive sources. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8-160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal. The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analyzed in detail. We show that the calibration campaign is comprehensive, and the calibration results are generally consistent with simulations as expected.

astro-ph.IM

The design and performance of GRD onboard the GECAM satellite

Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are many key points to be studied. In this paper, we present the specific design scheme of GRD, the assembly and the performance test results of detectors. Methods: Based on Monte Carlo simulation and experimental test results, the specific schematic design and assembling process ofGRDwere optimized. After being fully assembled, theGRDswere conducted performance tests by using radioactive source and also conducted random vibration tests. Result and conclusion: The test results show that all satellite-borne GRDs have energy resolution <16% at 59.5 keV, meeting requirements of satellite in scientific performance. The random vibration test shows that GRD can maintain in a stable performance, which meets the requirement of spatial application.

astro-ph.IM

GECAM detection of a bright type-I X-ray burst from 4U 0614+09: confirmation its spin frequency at 413 Hz

One month after launching Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM), a bright thermonuclear X-ray burst from 4U~0614+09, was observed on January 24, 2021. We report the time-resolved spectroscopy of the burst and a burst oscillation detection at 413 Hz with a fractional amplitude 3.4\% (rms). This coincides with the burst oscillation previously discovered with \textit{Swift}/BAT \citep{Strohmayer2008}, and therefore confirms the spin frequency of this source. This burst is the brightest one in the normal bursts (except the superburst) ever detected from 4U~0614+09, which leads to an upper limit of distance estimation as 3.1 kpc. The folded light curve during the burst oscillation shows a multi-peak structure, which is the first case observed during a single burst oscillation in nonpulsating sources. The multi-peak profile could be due to additional harmonics of the burst oscillation, which is corresponding to several brighter/fainter spots at the stellar surface.

astro-ph.HE

Bidirectional switching assisted by interlayer exchange coupling in asymmetric magnetic tunnel junctions

We study the combined effects of spin transfer torque, voltage modulation of interlayer exchange coupling and magnetic anisotropy on the switching behavior of perpendicular magnetic tunnel junctions (p-MTJs). In asymmetric p-MTJs, a linear-in-voltage dependence of interlayer exchange coupling enables the effective perpendicular anisotropy barrier to be lowered for both voltage polarities. This mechanism is shown to reduce the critical switching current and effective activation energy. Finally, we analyze the possibility of having switching via interlayer exchange coupling only.

cond-mat.mtrl-sci

Intrinsic Room Temperature Ferromagnetism in Boron-doped ZnO

We report room temperature ferromagnetism in boron-doped ZnO both experimentally and theoretically. The single phase Zn1-xBxO films deposited under high oxygen pressure by pulsed-laser deposition show ferromagnetic behavior at room temperature. The saturation magnetization increases monotonously from 0 to 1.5 emu/cm3 with the increasing of B component x from 0 to 6.8%. The first-principles calculations based on density functional theory demonstrate that the ferromagnetism in B-doped ZnO originates from the induced magnetic moments of oxygen atoms in the nearest neighbor sites to the B-Zn vacancy pair. The calculated total magnetic moment increasing tendency with B component is well consistent with experiments.

cond-mat.mtrl-sci

Synthetic antiferromagnet with Heusler alloy Co2FeAl ferromagnetic layers

Heusler alloy Co2FeAl was employed as ferromagnetic layers in Co2FeAl/Ru/Co2FeAl synthetic antiferromagnet structures. The experimental results show that the structure with a Ru thickness of 0.45 nm takes on strongly antiferromagnetic coupling, which maintains up to 150 oC annealing for 1 hour. The structure has a very low saturation magnetization Ms of 425 emu/cc, a low switching field Hsw of 4.3 Oe and a high saturation field Hs of 5257 Oe at room temperature, which are favorable for application in ultrahigh density magnetic read heads or other magnetic memory devices. XRD study testifies that the as-deposited Co2FeAl film is in B2 phase. Therefore Heusler alloys can be used to fabricate SyAF and it is possible to make "all-Heusler" spin-valves or magnetic tunneling junctions with better magnetic switching properties and high magnetoresistance.

cond-mat.mtrl-sci

Observation of room-temperature spontaneous phase segregation in overdoped Bi$_2$Sr$_2$CaCu$_2$O$_{8+x}

The occurrence and development of phase inhomogeneity in {\rm Bi$_2$Sr$_2$CaCu$_2$O$_{8+x}$} single crystals have been investigated by measuring their superconducting transition patterns using a high-sensitivity ac magnetometer. We find that the overdoped {\rm Bi$_2$Sr$_2$CaCu$_2$O$_{8+x}$} single crystals, even if they were single-phased immediately after a high-temperature annealing process, show progressively pronounced multiple superconducting transitions with time as they were kept at room temperature in a dry air atmosphere. The results reveal that the oxygen dopants in the crystal are still mobile at room temperature. These dopants tend to re-arrange and thus form different phases, at a characteristic time scale of one or two weeks or so. Moreover, the diamagnetization loops in the newly segregated phase are very weak, presumably due to the existence of additional inhomogeneity down to a nanometer scale. Our results also show that the optimally doped {\rm Bi$_2$Sr$_2$CaCu$_2$O$_{8+x}$} crystals seem capable to remain in a single phase with time.

cond-mat.supr-con

3 omega method for specific heat and thermal conductivity measurements

We present a 3 omega method for simultaneously measuring the specific heat and thermal conductivity of a rod- or filament-like specimen using a way similar to a four-probe resistance measurement. The specimen in this method needs to be electrically conductive and with a temperature-dependent resistance, for acting both as a heater to create a temperature fluctuation and as a sensor to measure its thermal response. With this method we have successfully measured the specific heat and thermal conductivity of platinum wire specimens at cryogenic temperatures, and measured those thermal quantities of tiny carbon nanotube bundles some of which are only 10^-9 g in mass.

quant-ph