SearcharxivSearch

arXiv subjects

D. Marlow

Publications and source records attributed to D. Marlow.

7 recordsLinked to original sources

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.

physics.ins-det

Ultrafast opacity in borosilicate glass induced by picosecond bursts of laser-driven ions

Direct investigation of ion-induced dynamics in matter on picosecond (ps, 10-12 s) timescales has been precluded to date by the relatively long nanosecond (ns, 10-9 s) scale ion pulses typically provided by radiofrequency accelerators1. By contrast, laser-driven ion accelerators provide bursts of ps duration2, but have yet to be applied to the study of ultrafast ion-induced transients in matter. We report on the evolution of an electron-hole plasma excited in borosilicate glass by such bursts. This is observed as an onset of opacity to synchronised optical probe radiation and is characterised by the 3.0 +/- 0.8 ps ion pump rise-time . The observed decay-time of 35 +/- 3 ps i.e. is in excellent agreement with modelling and reveals the rapidly evolving electron temperature (>10 3 K) and carrier number density (>10 17cm-3). This result demonstrates that ps laser accelerated ion bursts are directly applicable to investigating the ultrafast response of matter to ion interactions and, in particular, to ultrafast pulsed ion radiolysis of water3-5, the radiolytic decompositions of which underpin biological cell damage and hadrontherapy for cancer treatment6.

physics.plasm-ph

Performance of a Low Noise Front-end ASIC for Si/CdTe Detectors in Compton Gamma-ray Telescope

Compton telescopes based on semiconductor technologies are being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of such Compton telescopes is the high energy resolution that is crucial for high angular resolution and high background rejection capability. The energy resolution around 1 keV is required to approach physical limit of the angular resolution due to Doppler broadening. We have developed a low noise front-end ASIC (Application-Specific Integrated Circuit), VA32TA, to realize this goal for the readout of Double-sided Silicon Strip Detector (DSSD) and Cadmium Telluride (CdTe) pixel detector which are essential elements of the semiconductor Compton telescope. We report on the design and test results of the VA32TA. We have reached an energy resolution of 1.3 keV (FWHM) for 60 keV and 122 keV at 0 degree C with a DSSD and 1.7 keV (FWHM) with a CdTe detector.

astro-ph

A complete infrared Einstein ring in the gravitational lens system B1938+666

We report the discovery, using NICMOS on the Hubble Space Telescope, of an arcsecond-diameter Einstein ring in the gravitational lens system B1938+666. The lensing galaxy is also detected, and is most likely an early-type. Modelling of the ring is presented and compared with the radio structure from MERLIN maps. We show that the Einstein ring is consistent with the gravitational lensing of an extended infrared component, centred between the two radio components.

astro-ph

The Cherenkov Correlated Timing Detector: Beam Test Results from Quartz and Acrylic Bars

Several prototypes of a Cherenkov Correlated Timing (CCT) Detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype.

hep-ex

First Results from the BELLE DIRC Prototype

The DIRC (Detection of Internally Reflected Cerenkov light) is a new type of ring imaging Cerenkov detector, which detects images from Cerenkov light produced in precisely machined quartz bars. The Cerenkov images are transported along several meters of bar to the edge of the detector where they are proximity focussed unto an array of conventional photomultiplier tubes. Results from a prototype device comprising a 2 x 4 x 240 cm**3 quartz bar read by an array of 480 PMT's are presented. Sample images, which are the first observed in this type of detector, are shown. Measurements of the light yield (approximately 20 photoelectrons per image) and the angular resolution are in good agreement with Monte Carlo predictions.

hep-ex