Searcharxiv⌕ Search

arXiv subjects

D. N. McKinsey

Publications and source records attributed to D. N. McKinsey.

102 records · Page 6Linked to original sources

Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration

We report the preparation of neutron-activated xenon for the calibration of liquid xenon (LXe) detectors. Gamma rays from the decay of xenon metastable states, produced by fast neutron activation, were detected and their activities measured in a LXe scintillation detector. Following a five-day activation of natural xenon gas with a Cf-252 (4 x 10^5 n/s) source, the activities of two gamma ray lines at 164 keV and 236 keV, from Xe-131m and Xe-129m metastable states, were measured at about 95 and 130 Bq/kg, respectively. We also observed three additional lines at 35 keV, 100 keV and 275 keV, which decay away within a few days. No long-lifetime activity was observed after the neutron activation.

physics.ins-det↗

Toward Application of a Thick Gas Electron Multiplier (THGEM) Readout for a Dark Matter Detector

The Yale-Weizmann collaboration aims to develop a low-radioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON collaboration. A major issue is the background induced by natural radioactivity of present-detector components including the Photo Multiplier Tubes (PMT) made from glass with large U-Th content. We propose to use advanced Thick Gaseous Electron Multipliers (THGEM) recently developed at the Weizmann Institute of Science (WIS). These "hole-multipliers" will measure in a two-phase (liquid/gas) Xe detector electrons extracted into the gas phase from both ionization in the liquid as well as scintillation-induced photoelectrons from a CsI photocathode immersed in LXe. We report on initial tests (in gas) of THGEM made out of Cirlex (Kapton) which is well known to have low Ra-Th content instead of the usual G10 material with high Ra-Th content.

physics.ins-det↗

Scintillation of liquid neon from electronic and nuclear recoils

We have measured the time dependence of scintillation light from electronic and nuclear recoils in liquid neon, finding a slow time constant of 15.4+-0.2 us. Pulse shape discrimination is investigated as a means of identifying event type in liquid neon. Finally, the nuclear recoil scintillation efficiency is measured to be 0.26+-0.03 for 387 keV nuclear recoils.

astro-ph↗

Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils

Liquid Xenon (LXe) is expected to be an excellent target and detector medium to search for dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Knowledge of LXe ionization and scintillation response to low energy nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important for determining the sensitivity of LXe direct detection experiments. Here we report on new measurements of the scintillation yield of Xe recoils with kinetic energy as low as 10 keV. The dependence of the scintillation yield on applied electric field was also measured in the range of 0 to 4 kV/cm. Results are in good agreement with recent theoretical predictions that take into account the effect of biexcitonic collisions in addition to the nuclear quenching effect.

astro-ph↗

Trace Detection of Metastable Helium Molecules in Superfluid Helium by Laser-Induced Fluorescence

We describe an approach to detecting ionizing radiation that combines the special properties of superfluid helium with the sensitivity of quantum optics techniques. Ionization in liquid helium results in the copious production of metastable helium molecules, which can be detected by laser-induced fluorescence. Each molecule can be probed many times using a cycling transition, resulting in the detection of individual molecules with high signal to noise. This technique could be used to detect neutrinos, weakly interacting massive particles, and ultracold neutrons, and to image superfluid flow in liquid He-4.

nucl-ex↗

Radioactive Krypton Background Evaluation Using Atom Counting

The beta-decay of $\rm^{85}Kr$ is a significant radioactive background for experiments that use liquified noble gases to search for dark matter and measure the low-energy solar neutrino flux. While there are several proposed methods for reducing Kr levels in these experiments, an independent technique is needed for measuring very low Kr levels. By selectively exciting Kr atoms to a metastable state, capturing them in a magneto-optical trap (MOT), and detecting fluorescence from the trapped atoms, individual Kr atoms can be counted with a high signal-to-noise ratio. This approach could be used to ascertain Kr impurity levels in other noble gases, with an estimated sensitivity of $3\times 10^{-14}$.

astro-ph↗

Neutrino Detection With CLEAN

This article describes CLEAN, an approach to the detection of low-energy solar neutrinos and neutrinos released from supernovae. The CLEAN concept is based on the detection of elastic scattering events (neutrino-electron scattering and neutrino-nuclear scattering) in liquified noble gases such as liquid helium, liquid neon, and liquid xenon, all of which scintillate brightly in the ultraviolet. Key to the CLEAN technique is the use of a thin film of wavelength-shifting fluor to convert the ultraviolet scintillation light to the visible. This allows the same liquid to be used as both a passive shielding medium and an active self-shielding detector, allowing lower intrinsic radioactive backgrounds at low energies. Liquid neon is a particularly promising medium for CLEAN. Because liquid neon has a high scintillation yield, has no long-lived radioactive isotopes, and can be easily purified by use of cold traps, it is an ideal medium for the detection of rare nuclear events. In addition, neon is inexpensive, dense, and transparent to its own scintillation light, making it practical for use in a large self-shielding apparatus. Monte Carlo simulations of gamma ray backgrounds have been performed assuming liquid neon as both shielding and detection medium. Gamma ray events occur with high probability in the outer parts of the detector. In contrast, neutrino scattering events occur uniformly throughout the detector. We discriminate background gamma ray events from events of interest based on a spatial Maximum Likelihood method estimate of event location. Background estimates for CLEAN are presented, as well as an evaluation of the sensitivity of the detector for $p-p$ neutrinos. Given these simulations, the physics potential of the CLEAN approach is evaluated.

astro-ph↗

Supernova Observation Via Neutrino-Nucleus Elastic Scattering in the CLEAN Detector

Development of large mass detectors for low-energy neutrinos and dark matter may allow supernova detection via neutrino-nucleus elastic scattering. An elastic-scattering detector could observe a few, or more, events per ton for a galactic supernova at 10 kpc ($3.1 \times 10^{20}$ m). This large yield, a factor of at least 20 greater than that for existing light-water detectors, arises because of the very large coherent cross section and the sensitivity to all flavors of neutrinos and antineutrinos. An elastic scattering detector can provide important information on the flux and spectrum of $ν_μ$ and $ν_τ$ from supernovae. We consider many detectors and a range of target materials from $^4$He to $^{208}$Pb. Monte Carlo simulations of low-energy backgrounds are presented for the liquid-neon-based Cryogenic Low Energy Astrophysics with Noble gases (CLEAN) detector. The simulated background is much smaller than the expected signal from a galactic supernova.

astro-ph↗

Magnetically Stabilized Luminescent Excitations in Hexagonal Boron Nitride

Magnetically stabilized luminescence is observed in hexagonal boron nitride. The luminescence is induced by absorption of cold neutrons and is in the visible region. In the absence of a magnetic field, the photon emission level is observed to decay over several hundred seconds. A fraction of this luminescence can be suppressed if the temperature is T <~ 0.6 K and the magnetic field is B >~ 1.0 T. Subsequent to irradiation and suppression, luminescence can be induced by an increase in T or lowering of B. Possible explanations include stabilization of triplet states or the localization and stabilization of excitons.

cond-mat↗

Magnetic trapping of ultracold neutrons

Three-dimensional magnetic confinement of neutrons is reported. Neutrons are loaded into an Ioffe-type superconducting magnetic trap through inelastic scattering of cold neutrons with 4He. Scattered neutrons with sufficiently low energy and in the appropriate spin state are confined by the magnetic field until they decay. The electron resulting from neutron decay produces scintillations in the liquid helium bath that results in a pulse of extreme ultraviolet light. This light is frequency downconverted to the visible and detected. Results are presented in which 500 +/- 155 neutrons are magnetically trapped in each loading cycle, consistent with theoretical predictions. The lifetime of the observed signal, 660 s +290/-170 s, is consistent with the neutron beta-decay lifetime.

nucl-ex↗

Magnetic Trapping of Neutrons

Accurate measurement of the lifetime of the neutron (which is unstable to beta decay) is important for understanding the weak nuclear force and the creation of matter during the Big Bang. Previous measurements of the neutron lifetime have mainly been limited by certain systematic errors; however, these could in principle be avoided by performing measurements on neutrons stored in a magnetic trap. Neutral and charged particle traps are widely used tool for studying both composite and elementary particles, because they allow long interaction times and isolation from perturbing environments. Here we report the magnetic trapping of neutrons. The trapping region is filled with superfluid 4-He, which is used to load neutrons into the trap and as a scintillator to detect their decay. Neutrons have a lifetime in the trap of 750 +330/-200 seconds, mainly limited by their beta decay rather than trap losses. Our experiment verifies theoretical predictions regarding the loading process and magnetic trapping of neutrons. Further refinement of this method should lead to improved precision in the neutron lifetime measurement.

nucl-ex↗

Liquid Helium and Liquid Neon - Sensitive, Low Background Scintillation Media For the Detection of Low Energy Neutrinos

The use of liquid helium and neon as scintillators for neutrino detection is investigated. Several unique properties of these cryogens make them promising candidates for real-time solar neutrino spectroscopy: large ultraviolet scintillation yields from ionizing radiation, transparency to their own scintillation light, and low levels of radioactive impurities. When neutrinos scatter from electrons in liquid helium or neon, ultraviolet light is emitted. The ultraviolet scintillation light can be efficiently converted to the visible with wavelength shifting films. In this way the neutrino-electron scattering events can be detected by photomultiplier tubes at room temperature. We conclude that the solar neutrino flux from the $\rm p+p\to e^{+}+d+ν_{e}$ reaction could be characterized and monitored versus time using a 10 ton mass of liquid helium or neon as a scintillation target.

astro-ph↗