SearcharxivSearch

arXiv subjects

D. Naito

Publications and source records attributed to D. Naito.

6 recordsLinked to original sources

LLRF upgrade status at the KEK Photon Factory 2.5 GeV ring

In 2023, we are replacing the LLRF system for the KEK-PF 2.5 GeV ring. The new system is composed of digital boards such as eRTM, AMC, and μRTM, based on the MTCA.4 standard. In our system, we adopted the non-IQ direct sampling method for RF detection. We set the sampling frequency at 8/13 (307.75 MHz) of the RF frequency, where the denominator (13) is the divisor of the harmonic number (312) of the storage ring. This allows us to detect the transient variation of the cavity voltage that is synchronized with the beam revolution. We also plan to compensate for the voltage variation by implementing a feedforward technique. These functions will be useful in a double RF system for KEK future synchrotron light source. Production and installation of the new system were complete and the new system is under commissioning. In this presentation, we introduce our new system and report the upgrade status.

physics.acc-ph

Search for $K_L \!\to\! π^0 ν\overlineν$ and $K_L \!\to\! π^0 X^0$ Decays at the J-PARC KOTO Experiment

A search for the rare decay $K_L \!\to\! π^0 ν\overlineν$ was performed. With the data collected in 2015, corresponding to $2.2 \times 10^{19}$ protons on target, a single event sensitivity of $( 1.30 \pm 0.01_{\rm stat} \pm 0.14_{\rm syst} ) \times 10^{-9}$ was achieved and no candidate events were observed. We set an upper limit of $3.0 \times 10^{-9}$ for the branching fraction of $K_L \!\to\! π^0 ν\overlineν$ at the 90% confidence level (C.L.), which improved the previous limit by almost an order of magnitude. An upper limit for $K_L \!\to\! π^0 X^0$ was also set as $2.4 \times 10^{-9}$ at the 90% C.L., where $X^0$ is an invisible boson with a mass of $135~{\rm MeV}/c^2$.

hep-ex

A new search for the $K_{L} \to π^0 ν\overlineν$ and $K_{L} \to π^{0} X^{0}$ decays

We searched for the $CP$-violating rare decay of neutral kaon, $K_{L} \to π^0 ν\overlineν$, in data from the first 100 hours of physics running in 2013 of the J-PARC KOTO experiment. One candidate event was observed while $0.34\pm0.16$ background events were expected. We set an upper limit of $5.1\times10^{-8}$ for the branching fraction at the 90\% confidence level (C.L.). An upper limit of $3.7\times10^{-8}$ at the 90\% C.L. for the $K_{L} \to π^{0} X^{0}$decay was also set for the first time, where $X^{0}$ is an invisible particle with a mass of 135 MeV/$c^{2}$.

hep-ex

Long-lived neutral-kaon flux measurement for the KOTO experiment

The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.

physics.ins-det

Development of a low-mass and high-efficiency charged particle detector

We developed a low-mass and high-efficiency charged particle detector for an experimental study of the rare decay $K_L \rightarrow π^0 ν\barν$. The detector is important to suppress the background with charged particles to the level below the signal branching ratio predicted by the Standard Model (O(10$^{-11}$)). The detector consists of two layers of 3-mm-thick plastic scintillators with wavelength shifting fibers embedded and Multi Pixel Photon Counters for readout. We manufactured the counter and evaluated the performance such as light yield, timing resolution, and efficiency. With this design, we achieved the inefficiency per layer against penetrating charged particles to be less than $1.5 \times 10^{-5}$, which satisfies the requirement of the KOTO experiment determined from simulation studies.

physics.ins-det

An aerogel Cherenkov detector for multi-GeV photon detection with low sensitivity to neutrons

We describe a novel photon detector which operates under an intense flux of neutrons. It is composed of lead-aerogel sandwich counter modules. Its salient features are high photon detection efficiency and blindness to neutrons. As a result of Monte Carlo (MC) simulations, the efficiency for photons with the energy larger than 1 GeV is expected to be higher than 99.5% and that for 2 GeV/$c$ neutrons less than 1%. The performance on the photon detection under such a large flux of neutrons was measured for a part of the detector. It was confirmed that the efficiency to photons with the energy $>$1 GeV was consistent with the MC expectation within 8.2% uncertainty.

physics.ins-det