SearcharxivSearch

arXiv subjects

D. Osite

Publications and source records attributed to D. Osite.

2 recordsLinked to original sources

The CMS Barrel Timing Layer: test beam confirmation of module timing performance

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30-60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 $\rm \mu m$ cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.

physics.ins-det

Angular momentum alignment-to-orientation conversion in the ground state of Rb atoms at room temperature

We investigated experimentally and theoretically angular momentum alignment-to-orientation conversion created by the joint interaction of laser radiation and an external magnetic field with atomic rubidium at room temperature. In particular we were interested in alignment-to-orientation conversion in atomic ground state. Experimentally the laser frequency was fixed to the hyperfine transitions of $D_1$ line of rubidium. We used a theoretical model for signal simulations that takes into account all neighboring hyperfine levels, the mixing of magnetic sublevels in an external magnetic field, the coherence properties of the exciting laser radiation, and the Doppler effect. The experiments were carried out by exciting the atoms with linearly polarized laser radiation. Two oppositely circularly polarized laser induced fluorescence (LIF) components were detected and afterwards their difference was taken. The combined LIF signals originating from the hyperfine magnetic sublevel transitions of $^{85}$Rb and $^{87}$Rb rubidium isotopes were included. The alignment-to-orientation conversion can be undoubtedly identified in the difference signals for various laser frequencies as well as change in signal shapes can be observed when the laser power density is increased. We studied the formation and the underlying physical processes of the observed signal of the LIF components and their difference by performing the analysis of the influence of incoherent and coherent effects. We performed simulations of theoretical signals that showed the influence of ground-state coherent effects on the LIF difference signal.

physics.atom-ph