SearcharxivSearch

arXiv subjects

D. Petyt

Publications and source records attributed to D. Petyt.

4 recordsLinked to original sources

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8$\times$8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 $\mu$m per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

physics.ins-det

The Stochastic Light Confinement of LiquidO

Light-based detectors have been widely used in fundamental research and industry since their inception in the 1930s. The energy particles deposit in these detectors is converted to optical signals via the Cherenkov and scintillation mechanisms that are then propagated through transparent media to photosensors placed typically on the detector's periphery, sometimes up to tens of metres away. LiquidO is a new technique pioneering the use of opaque media to stochastically confine light around each energy deposition while collecting it with an array of fibres that thread the medium. This approach preserves topological event information otherwise lost in the conventional approach, enabling real-time imaging down to the MeV scale. Our article demonstrates LiquidO's imaging principle with a ten-litre prototype, revealing successful light confinement of 90% of the detected light within a 5 cm radius sphere, using a custom opaque scintillator with a scattering length on the order of a few millimetres. These high-resolution imaging capabilities unlock opportunities in fundamental physics research and applications beyond. The absolute amount of light detected is also studied, including possible data-driven extrapolations to LiquidO-based detectors beyond prototyping limitations. Additionally, LiquidO's timing capabilities are explored through its ability to distinguish Cherenkov light from a slow scintillator.

physics.ins-det

COCOA: a compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

astro-ph.IM

Comparisons of the MINOS Near and Far Detector Readout Systems at a Test Beam

MINOS is a long baseline neutrino oscillation experiment that uses two detectors separated by 734 km. The readout systems used for the two detectors are different and have to be independently calibrated. To verify and make a direct comparison of the calibrated response of the two readout systems, test beam data were acquired using a smaller calibration detector. This detector was simultaneously instrumented with both readout systems and exposed to the CERN PS T7 test beam. Differences in the calibrated response of the two systems are shown to arise from differences in response non-linearity, photomultiplier crosstalk, and threshold effects at the few percent level. These differences are reproduced by the Monte Carlo (MC) simulation to better than 1% and a scheme that corrects for these differences by calibrating the MC to match the data in each detector separately is presented. The overall difference in calorimetric response between the two readout systems is shown to be consistent with zero to a precision of 1.3% in data and 0.3% in MC with no significant energy dependence.

physics.ins-det