SearcharxivSearch

arXiv subjects

D. Pocanic

Publications and source records attributed to D. Pocanic.

At least 37 records · Page 2Linked to original sources

Nab: Measurement Principles, Apparatus and Uncertainties

The Nab collaboration will perform a precise measurement of 'a', the electron-neutrino correlation parameter, and 'b', the Fierz interference term in neutron beta decay, in the Fundamental Neutron Physics Beamline at the SNS, using a novel electric/magnetic field spectrometer and detector design. The experiment is aiming at the 10^{-3} accuracy level in (Delta a)/a, and will provide an independent measurement of lambda = G_A/G_V, the ratio of axial-vector to vector coupling constants of the nucleon. Nab also plans to perform the first ever measurement of 'b' in neutron decay, which will provide an independent limit on the tensor weak coupling.

nucl-ex

The automatic gain-matching in the PIBETA CsI calorimeter

Segmented electromagnetic calorimeters are used to determine both the total energy and direction (momentum components) of charged particles and photons. A trade off is involved in selecting the degree of segmentation of the calorimeter as the spatial and energy resolutions are affected differently. Increased number of individual detectors reduces accidental particle pile-up per detector but introduces complications related to ADC pedestals and pedestal variations, exacerbates the effects of electronic noise and ground loops, and requires summing and discrimination of multiple analog signals. Moreover, electromagnetic showers initiated by individual ionizing particles spread over several detectors. This complicates the precise gain-matching of the detector elements which requires an iterative procedure. The PIBETA calorimeter is a 240-module pure CsI non-magnetic detector optimized for detection of photons and electrons in the energy range 5-100 MeV. We present the computer-controlled, automatic, in situ gain-matching procedure that we developed and used routinely in several rare pion and muon decay experiments with the PIBETA detector.

physics.ins-det

Proton Spin Structure in the Resonance Region

We have examined the spin structure of the proton in the region of the nucleon resonances (1.085 GeV < W < 1.910 GeV) at an average four momentum transfer of Q^2 = 1.3 GeV^2. Using the Jefferson Lab polarized electron beam, a spectrometer, and a polarized solid target, we measured the asymmetries A_parallel and A_perp to high precision, and extracted the asymmetries A_1 and A_2, and the spin structure functions g_1 and g_2. We found a notably non-zero A_perp, significant contributions from higher-twist effects, and only weak support for polarized quark--hadron duality.

nucl-ex

Measurement of stopping beam distributions in the PIBETA detector

Precise calculation of the geometrical acceptance of a large solid angle detector with an integrated stopping target relies on precise knowledge of the beam geometry. We describe four alternative methods that we used to measure the beam stopping distributions in the PIBETA detector active target: (i) light response of segmented target elements to incident beam particles, (ii) back-tracking of charged particles from pi+ and mu+ decays using multi-wire proportional chambers, (iii) volume distribution of the Dalitz decay (pi0->gamma e+e-) event vertices, and (iv) the opening angle distribution of two pi0 photons originating from the beta decay of pi+ at rest. We demonstrate consistent results obtained by these four independent approaches and show how particular beam stopping distributions affect the detector's geometrical acceptance.

hep-ex

Status of the Cabibbo Angle

We review the recent experimental and theoretical progress in the determination of |V_{ud}| and |V_{us}|, and the status of the most stringent test of CKM unitarity. Future prospects on |V_{cd}| and |V_{cs}| are also briefly discussed.

hep-ph

Precise Measurement of the Pi+ -> Pi0 e+ nu Branching Ratio

Using a large acceptance calorimeter and a stopped pion beam we have made a precise measurement of the rare Pi+ -> Pi0 e+ Nu,(pi_beta) decay branching ratio. We have evaluated the branching ratio by normalizing the number of observed pi_beta decays to the number of observed Pi+ -> e+ Nu, (pi_{e2}) decays. We find the value of Gamma(Pi+ -> Pi0 e+ Nu)/Gamma(total) = [1.036 +/- 0.004(stat.) +/- 0.004(syst.) +/- 0.003(pi_{e2})] x 10^{-8}$, where the first uncertainty is statistical, the second systematic, and the third is the pi_{e2} branching ratio uncertainty. Our result agrees well with the Standard Model prediction.

hep-ex

Precise Measurement of the Pion Axial Form Factor in the Pi+ -> e+ nu gamma Decay

We have studied radiative pion decays Pi+ -> e+ nu gamma in three broad kinematic regions using the PIBETA detector and a stopped pion beam. Based on Dalitz distributions of 42,209 events we have evaluated absolute Pi -> e nu gamma branching ratios in the three regions. Minimum chi^2 fits to the integral and differential (E(e+),E(gamma)) distributions result in the axial-to-vector weak form factor ratio of gamma = F_A/F_V = 0.443(15),or F_A = 0.0115(4) with F_V = 0.0259. However, deviations from Standard Model predictions in the high-E(gamma)/low-E(e+) kinematic region indicate the need for further theoretical and experimental work.

hep-ex

Design, Commissioning and Performance of the PIBETA Detector at PSI

We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.

hep-ex

New Results from the PIBETA Experiment

We report interim results of the PIBETA experiment analysis for the pion beta decay and pion radiative decay. The former is in excellent agreement with the SM predictions at the 1% accuracy level.

hep-ph

Radiation hardness of the PIBETA detector components

We have examined long term changes in signal amplitude gain, energy resolution and detection efficiency for the active components of the PIBETA detector system. Beam defining plastic scintillation counters were operated in a ~1 MHz stopped $π^+$ beam for a period of 297 days, accumulating radiation doses of up to 2 Mrad. Detectors in the charged particle tracking system--a pair of cylindrical multi-wire proportional chambers and a thin plastic scintillation barrel-shaped hodoscope array--were irradiated during the same running period with an average dose of ~40 krad. Individual CsI(undoped crystal) calorimeter detectors received an average dose of ~120 rad, mainly from photons, positrons and protons originating from $π^+$ hadronic interactions as well as from $π^+$ and $μ^+$ weak decays at rest in the active target.

physics.ins-det

ADC common noise correction and zero suppression in the PIBETA detector

We describe a simple procedure for reducing ADC common noise in modular detectors that does not require additional hardware. A method using detector noise groups should work well for modular particle detectors such as segmented electromagnetic calorimeters, plastic scintillator hodoscopes, cathode strip wire chambers, segmented active targets, and the like. We demonstrate a ``second pedestal noise correction'' method by comparing representative ADC pedestal spectra for various elements of the PIBETA detector before and after the applied correction.

hep-ex

The KARMEN Time Anomaly: Search for a Neutral Particle of Mass 33.9 MeV in Pion Decay

We have searched for the pion decay pi^+ --> mu^+ X, where X is a neutral particle of mass 33.905 MeV. This process was suggested by the KARMEN Collaboration to explain an anomaly in their observed time distribution of neutrino induced reactions. Having measured the muon momentum spectrum of charged pions decaying in flight, we find no evidence for this process and place an upper limit on the branching fraction eta leq 6.0 * 10^{-10} of such a decay at a 95% confidence level.

hep-ex

Optics: general-purpose scintillator light response simulation code

We present the program optics that simulates the light response of an arbitrarily shaped scintillation particle detector. Predicted light responses of pure CsI polygonal detectors, plastic scintillator staves, cylindrical plastic target scintillators and a Plexiglas light-distribution plate are illustrated. We demonstrate how different bulk and surface optical properties of a scintillator lead to specific volume and temporal light collection probability distributions. High-statistics optics simulations are calibrated against the detector responses measured in a custom-made cosmic muon tomography apparatus. The presented code can also be used to track particles intersecting complex geometrical objects.

hep-ex

Light response of pure CsI calorimeter crystals painted with wavelength-shifting lacquer

We have measured scintillation properties of pure CsI crystals used in the shower calorimeter built for a precise determination of the pi+ -> pi0 e+ nu decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals painted with a special wavelength-shifting solution were examined in a custom-build detection apparatus (RASTA=radioactive source tomography apparatus) that uses a 137Cs radioactive gamma source, cosmic muons and a light emitting diode as complementary probes of the scintillator light response. We have extracted the total light output, axial light collection nonuniformities and timing responses of the individual CsI crystals. These results predict improved performance of the 3 pi sr PIBETA calorimeter due to the painted lateral surfaces of 240 CsI crystals. The wavelength-shifting paint treatment did not affect appreciably the total light output and timing resolution of our crystal sample. The predicted energy resolution for positrons and photons in the energy range of 10-100 MeV was nevertheless improved due to the more favorable axial light collection probability variation. We have compared simulated calorimeter ADC spectra due to 70 MeV positrons and photons with a Monte Carlo calculation of an ideal detector light response.

hep-ex

Cosmic muon tomography of pure cesium iodide calorimeter crystals

Scintillation properties of pure CsI crystals used in the shower calorimeter being built for precise determination of the pi+ -> pi0 e+ nu decay rate are reported. Seventy-four individual crystals, polished and wrapped in Teflon foil, were examined in a multiwire drift chamber system specially designed for transmission cosmic muon tomography. Critical elements of the apparatus and reconstruction algorithms enabling measurement of spatial detector optical nonuniformities are described. Results are compared with a Monte Carlo simulation of the light response of an ideal detector. The deduced optical nonuniformity contributions to the FWHM energy resolution of the PIBETA CsI calorimeter for the pi+ -> e+ nu 69.8 MeV positrons and the monoenergetic 70.8 MeV photons were 2.7% and 3.7%, respectively. The upper limit of optical nonuniformity correction to the 69.8 MeV positron low-energy tail between 5 MeV and 55 MeV was +0.2%, as opposed to the +0.3% tail contribution for the photon of the equivalent total energy. Imposing the 5 MeV calorimeter veto cut to suppress the electromagnetic losses, GEANT-evaluated positron and photon lineshape tail fractions summed over all above-threshold ADCs were found to be 2.36+-0.05(stat)+-0.20(sys)% and 4.68+-0.07(stat)+-0.20(sys)%, respectively.

hep-ex

Pion--Pion Scattering Experiments at Low Energy

This work reviews the available experimental information on the pi-pi scattering lengths, especially the recent near-threshold pi N -> pi pi N data from several laboratories and the related application of the Chew-Low-Goebel (CLG) technique well below 1 GeV/c momentum. At this time uncertainties stemming from non-pion-exchange backgrounds in near-threshold CLG studies appear to preclude a determination of the pi$-pi scattering lengths with the desired accuracy of 10% or better.

hep-ph

Low Energy Experiments on pi-pi Scattering

General interest in a precise determination of the threshold pi-pi amplitudes has recently increased markedly due to a controversy regarding the size of <0|qbar q|0>, the scalar quark condensate. This paper examines the current experimental information on the pi-pi scattering lengths, in particular the recent low energy pi N -> pi pi N data from several laboratories and the related application of the Chew-Low-Goebel technique well below 1 GeV/c momentum. It appears that uncertainties related to the treatment of non-pion-exchange backgrounds in these studies do not yet allow an unambiguous resolution of the <0|qbar q|0> size. However, near-term prospects for new model-independent results of improved precision are very good.

hep-ph

Differential cross sections for pion charge exchange on the proton at 27.5 MeV

We have measured pion single charge exchange differential cross sections on the proton at 27.5 MeV incident $π^-$ kinetic energy in the center of momentum angular range between $0^\circ$ and $55^\circ$. The extracted cross sections are compared with predictions of the standard pion-nucleon partial wave analysis and found to be in excellent agreement.

hep-ex