Searcharxiv⌕ Search

arXiv subjects

D. R. Leibrandt

Publications and source records attributed to D. R. Leibrandt.

13 recordsLinked to original sources

Quantum metrology algorithms for dark matter searches with clocks

Quantum algorithms such as dynamical decoupling can be used to improve the sensitivity of a quantum sensor to a signal while suppressing sensitivity to noise. Atomic clocks are among the most sensitive quantum sensors, with recent improvements in clock technology allowing for unprecedented precision and accuracy. These clocks are highly sensitive to variations in fundamental constants, making them ideal probes for local ultralight scalar dark matter. Further improvements to the sensitivity is expected in proposed nuclear clocks based on the thorium 229m isomer. We investigate the use of various quantum metrology algorithms in the search for dark matter using quantum clocks. We propose a new broadband dynamical decoupling algorithm and compare it with quantum metrology protocols that have been previously proposed and demonstrated, namely differential spectroscopy and narrowband dynamical decoupling. We conduct numerical simulations of scalar dark matter searches with realistic noise sources and accounting for dark matter decoherence. Finally, we discuss an alternative thorium nuclear transition excitation method that bypasses the technical challenges associated with vacuum ultraviolet lasers.

quant-ph↗

New Horizons: Scalar and Vector Ultralight Dark Matter

The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.

hep-ex↗

Lifetime-Limited Interrogation of Two Independent ${}^{27}\textrm{Al}^{+}$ Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the $^1S_0\leftrightarrow{}^3P_0$ transition in $^{27}$Al$^+$. By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of $1.12\times10^{15}$ Hz. The observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s $^3P_0$ state lifetime and supports a measurement instability of $(1.8\pm0.5)\times 10^{-16}/\sqrt{τ/\textrm{s}}$ for averaging periods longer than the probe duration when deadtime is negligible.

physics.atom-ph↗

Systematic uncertainty due to background-gas collisions in trapped-ion optical clocks

We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an $^{27}$Al$^+$ clock to enable a total fractional systematic uncertainty below $10^{-18}$. For this clock, with 38(19) nPa of room temperature H$_2$ background gas, we find that collisional heating generates a non-thermal distribution of motional states with a mean time-dilation shift of order $10^{-16}$ at the end of a 150 ms probe, which is not detected by sideband thermometry energy measurements. However, the contribution of collisional heating to the spectroscopy signal is highly suppressed and we calculate the BGC shift to be $-0.6(2.4)\times 10^{-19}$, where the shift is due to collisional heating time-dilation and the uncertainty is dominated by the worst case $\pm π/2$ bound used for collisional phase shift of the $^{27}$Al$^+$ superposition state. We experimentally validate the framework and determine the background-gas pressure in situ using measurements of the rate of collisions that cause reordering of mixed-species ion pairs.

physics.atom-ph↗

Measurements of $^{27}$Al$^{+}$ and $^{25}$Mg$^{+}$ magnetic constants for improved ion clock accuracy

We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the $^{27}$Al$^{+}$ quantum-logic clock systematic uncertainty. The measurement of $C_{2}$ is in agreement with a previous measurement and a new calculation at the $1~σ$ level. The measurement of $ΔW$ is in good agreement with a recent measurement and differs from a previously published result by approximately $2σ$. With the improved value for $ΔW$, we deduce an improved value for the nuclear-to-electronic g-factor ratio $g_{I}/g_{J} = 9.299 ~308 ~313(60) \times 10^{-5}$ and the nuclear g-factor for the $^{25}$Mg nucleus $g_{I} = 1.861 ~957 ~82(28) \times 10^{-4}$. Using the values of $C_{2}$ and $ΔW$ presented here, we derive a quadratic Zeeman shift of the $^{27}$Al$^{+}$ quantum-logic clock of $Δν/ ν= -(9241.8 \pm 3.7) \times 10^{-19}$, for a bias magnetic field of $B \approx 0.12$~mT.

physics.atom-ph↗

An $^{27}$Al$^{+}$ quantum-logic clock with systematic uncertainty below $10^{-18}$

We describe an optical atomic clock based on quantum-logic spectroscopy of the $^1$S$_0$ $\leftrightarrow$ $^3$P$_0$ transition in $^{27}$Al$^{+}$ with a systematic uncertainty of ${9.4 \times 10^{-19}}$ and a frequency stability of ${1.2\times10^{-15}/\sqrtτ}$. A $^{25}$Mg$^{+}$ ion is simultaneously trapped with the $^{27}$Al$^{+}$ ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous $^{27}$Al$^{+}$ clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous $^{27}$Al$^{+}$ clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.

physics.atom-ph↗

Sympathetic ground state cooling and time-dilation shifts in an $^{27}\text{Al}^+$ optical clock

We report on Raman sideband cooling of ${^{25}\text{Mg}^+}$ to sympathetically cool the secular modes of motion in a $^{25}\text{Mg}^+$-$^{27}\!\text{Al}^+$ two-ion pair to near the three-dimensional (3D) ground state. The evolution of the Fock-state distribution during the cooling process is studied using a rate-equation simulation, and various heating sources that limit the efficiency of 3D sideband cooling in our system are discussed. We characterize the residual energy and heating rates of all of the secular modes of motion and estimate a secular motion time-dilation shift of ${-(1.9 \pm 0.1)\times 10^{-18}}$ for an ${^{27}\text{Al}^+}$ clock at a typical clock probe duration of $150$ ms. This is a 50-fold reduction in the secular motion time-dilation shift uncertainty in comparison with previous ${^{27}\text{Al}^+}$ clocks.

physics.atom-ph↗

Hyperfine-mediated electric quadrupole shifts in Al$^+$ and In$^+$ ion clocks

We evaluate the electric quadrupole moments of the ${^1}\!S_0$ and ${^3}\!P_0$ clock states of $^{27}$Al$^+$ and $^{115}$In$^+$. To capture all dominant contributions, our analysis extends through third order of perturbation theory and includes hyperfine coupling of the electrons to both the magnetic dipole and electric quadrupole moments of the nucleus. For $^{27}$Al$^+$, a fortuitous cancellation leads to a suppressed frequency shift. This should allow for continued improvement of the clock without special techniques to control or cancel the shift, such as the averaging schemes that are critical to other optical ion clocks.

physics.atom-ph↗

Exponential scaling of clock stability with atom number

In trapped-atom clocks, the primary source of decoherence is often the phase noise of the oscillator. For this case, we derive theoretical performance gains by combining several atomic ensembles. For example, M ensembles of N atoms can be combined with a variety of probe periods, to reduce the frequency variance to M 2^-M times that of standard Ramsey clocks. A similar exponential improvement is possible if the atomic phases of some of the ensembles evolve at reduced frequencies. These ensembles may be constructed from atoms or molecules with lower-frequency transitions, or generated by dynamical decoupling. The ensembles with reduced frequency or probe period are responsible only for counting the integer number of 2 pi phase wraps, and do not affect the clock's systematic errors. Quantum phase measurement with Gaussian initial states allows for smaller ensemble sizes than Ramsey spectroscopy.

quant-ph↗

Trapped-Ion State Detection through Coherent Motion

We demonstrate a general method for state detection of trapped ions that can be applied to a large class of atomic and molecular species. We couple a "spectroscopy" ion (Al+) to a "control" ion (Mg+) in the same trap and perform state detection through off-resonant laser excitation of the spectroscopy ion that induces coherent motion. The motional amplitude, dependent on the spectroscopy ion state, is measured either by time-resolved photon counting, or by resolved sideband excitations on the control ion. The first method provides a simplified way to distinguish "clock" states in Al+, which avoids ground state cooling and sideband transitions. The second method reduces spontaneous emission and optical pumping on the spectroscopy ion, which we demonstrate by nondestructively distinguishing Zeeman sublevels in the 1S0 ground state of Al+.

quant-ph↗

Ion crystal transducer for strong coupling between single ions and single photons

A new approach for realization of a quantum interface between single photons and single ions in an ion crystal is proposed and analyzed. In our approach the coupling between a single photon and a single ion is enhanced via the collective degrees of freedom of the ion crystal. Applications including single-photon generation, a memory for a quantum repeater, and a deterministic photon-photon, photon-phonon, or photon-ion entangler are discussed.

quant-ph↗

Demonstration of a scalable, multiplexed ion trap for quantum information processing

A scalable, multiplexed ion trap for quantum information processing is fabricated and tested. The trap design and fabrication process are optimized for scalability to small trap size and large numbers of interconnected traps, and for integration of control electronics and optics. Multiple traps with similar designs are tested with Cd+, Mg+, and Sr+ ions at room temperature and with Sr+ at 6 K, with respective ion lifetimes of 90 s, 300 +/- 30 s, 56 +/- 6 s, and 4.5 +/- 1.1 hours. The motional heating rate for Mg+ at room temperature and a trap frequency of 1.6 MHz is measured to be 7 +/- 3 quanta per millisecond. For Sr+ at 6 K and 540 kHz the heating rate is measured to be 220 +/- 30 quanta per second.

quant-ph↗

Experimental investigation of planar ion traps

Chiaverini et al. [Quant. Inf. Comput. 5, 419 (2005)] recently suggested a linear Paul trap geometry for ion trap quantum computation that places all of the electrodes in a plane. Such planar ion traps are compatible with modern semiconductor fabrication techniques and can be scaled to make compact, many zone traps. In this paper we present an experimental realization of planar ion traps using electrodes on a printed circuit board to trap linear chains of tens of 0.44 micron diameter charged particles in a vacuum of 15 Pa (0.1 torr). With these traps we address concerns about the low trap depth of planar ion traps and develop control electrode layouts for moving ions between trap zones without facing some of the technical difficulties involved in an atomic ion trap experiment. Specifically, we use a trap with 36 zones (77 electrodes) arranged in a cross to demonstrate loading from a traditional four rod linear Paul trap, linear ion movement, splitting and joining of ion chains, and movement of ions through intersections. We further propose an additional DC biased electrode above the trap which increases the trap depth dramatically, and a novel planar ion trap geometry that generates a two dimensional lattice of point Paul traps.

quant-ph↗