Searcharxiv⌕ Search

arXiv subjects

D. R. Tovey

Publications and source records attributed to D. R. Tovey.

At least 19 recordsLinked to original sources

LEP3: A High-Luminosity e+e- Higgs and ElectroweakFactory in the LHC Tunnel

As stated in the 2019 European Strategy for Particle Physics (ESPP), it is of the utmost importance that the HL-LHC upgrade of the accelerator and the experiments be successfully completed in a timely manner. All necessary efforts should be devoted to achieving this goal. We also recall two of the principal recommendations of the 2019 ESPP for future accelerator initiatives, namely that 1) An electron-positron Higgs factory is the highest priority for the next collider (Rec. c). 2) Europe, together with its international partners, should investigate the technical and financial feasibility of a future hadron collider at CERN with a centre-of-mass energy of at least 100 TeV and with an electron-positron Higgs and electroweak factory as a possible first stage (Rec. e). A major objective in particle physics is always to operate an accelerator that allows a leap of an order of magnitude in the constituent centre-of-mass energy with respect to the previous one. We support FCC-ee and FCC-hh as the preferred option for CERN future, as it addresses both of the above recommendations. The guidance for the 2025 ESPP requests, in addition to the preferred option, the inclusion of ``prioritised alternatives to be pursued if the chosen preferred option turns out not to be feasible or competitive''. Proposed alternatives to the preferred FCC option include linear, muon colliders and LHeC accelerators. In response to this request we propose reusing the existing LHC tunnel for an electron-positron collider, called LEP3, as a back-up alternative if the FCC cannot proceed. LEP3 leverages much of the R\&D conducted for FCC-ee, offers high-precision studies of Z, W, and Higgs bosons below the tt threshold, and offers potential physics performance comparable or superior to other fallback options at a lower cost while supporting continued R\&D towards a next-generation energy frontier machine.

physics.acc-ph↗

A hybrid method for determining particle masses at the Large Hadron Collider with fully identified cascade decays

A new technique for improving the precision of measurements of SUSY particle masses at the LHC is introduced. The technique involves kinematic fitting of events with two fully identified decay chains. We incorporate both event ETmiss constraints and independent constraints provided by kinematic end-points in experiment invariant mass distributions of SUSY decay products. Incorporation of the event specific information maximises the information used in the fit and is shown to reduce the mass measurement uncertainites by ~30% compared to conventional fitting of experiment end-point constraints for the SPS1a benchmark model.

hep-ph↗

Physics Beyond the Standard Model: Supersymmetry

This collection of studies on new physics at the LHC constitutes the report of the supersymmetry working group at the Workshop `Physics at TeV Colliders', Les Houches, France, 2007. They cover the wide spectrum of phenomenology in the LHC era, from alternative models and signatures to the extraction of relevant observables, the study of the MSSM parameter space and finally to the interplay of LHC observations with additional data expected on a similar time scale. The special feature of this collection is that while not each of the studies is explicitely performed together by theoretical and experimental LHC physicists, all of them were inspired by and discussed in this particular environment.

hep-ph↗

First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection

Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.

astro-ph↗

The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning

We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.

astro-ph↗

The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool

We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.

astro-ph↗

Constraining Dark Matter in the MSSM at the LHC

In the event that R-Parity conserving supersymmetry (SUSY) is discovered at the LHC, a key issue which will need to be addressed will be the consistency of that signal with astrophysical and non-accelerator constraints on SUSY Dark Matter. This issue is studied for the SPA benchmark model based on measurements of end-points and thresholds in the invariant mass spectra of various combinations of leptons and jets. These measurements are used to constrain the soft SUSY breaking parameters at the electroweak scale in a general MSSM model. Based on these constraints, we assess the accuracy with which the Dark Matter relic density can be measured.

hep-ph↗

Simulations of neutron background in a time projection chamber relevant to dark matter searches

Presented here are results of simulations of neutron background performed for a time projection chamber acting as a particle dark matter detector in an underground laboratory. The investigated background includes neutrons from rock and detector components, generated via spontaneous fission and (alpha, n) reactions, as well as those due to cosmic-ray muons. Neutrons were propagated to the sensitive volume of the detector and the nuclear recoil spectra were calculated. Methods of neutron background suppression were also examined and limitations to the sensitivity of a gaseous dark matter detector are discussed. Results indicate that neutrons should not limit sensitivity to WIMP-nucleon interactions down to a level of (1 - 3) x 10^{-8} pb in a 10 kg detector.

hep-ex↗

Les Houches "Physics at TeV Colliders 2003" Beyond the Standard Model Working Group: Summary Report

The work contained herein constitutes a report of the ``Beyond the Standard Model'' working group for the Workshop "Physics at TeV Colliders", Les Houches, France, 26 May--6 June, 2003. The research presented is original, and was performed specifically for the workshop. Tools for calculations in the minimal supersymmetric standard model are presented, including a comparison of the dark matter relic density predicted by public codes. Reconstruction of supersymmetric particle masses at the LHC and a future linear collider facility is examined. Less orthodox supersymmetric signals such as non-pointing photons and R-parity violating signals are studied. Features of extra dimensional models are examined next, including measurement strategies for radions and Higgs', as well as the virtual effects of Kaluza Klein modes of gluons. An LHC search strategy for a heavy top found in many little Higgs model is presented and finally, there is an update on LHC $Z'$ studies.

hep-ph↗

Neutron background in large-scale xenon detectors for dark matter searches

Simulations of the neutron background for future large-scale particle dark matter detectors are presented. Neutrons were generated in rock and detector elements via spontaneous fission and (alpha,n) reactions, and by cosmic-ray muons. The simulation techniques and results are discussed in the context of the expected sensitivity of a generic liquid xenon dark matter detector. Methods of neutron background suppression are investigated. A sensitivity of $10^{-9}-10^{-10}$ pb to WIMP-nucleon interactions can be achieved by a tonne-scale detector.

hep-ex↗

Constraining SUSY Dark Matter with the ATLAS Detector at the LHC

In the event that R-Parity conserving supersymmetry (SUSY) is discovered at the LHC, a key issue which will need to be addressed will be the consistency of that signal with astrophysical and non-accelerator constraints on SUSY Dark Matter. This issue is studied for the SPS1a mSUGRA benchmark model by using measurements of end-points and thresholds in the invariant mass spectra of various combinations of leptons and jets in ATLAS to constrain the model parameters. These constraints are then used to assess the statistical accuracy with which quantities such as the Dark Matter relic density and direct detection cross-section can be measured. Systematic effects arising from the use of different mSUGRA RGE codes are also estimated. Results indicate that for SPS1a a statistical(systematic) precision on the relic abundance ~ 2.8% (3 %) can be obtained given 300 fb-1 of data.

hep-ph↗

Proposal for a New Reconstruction Technique for SUSY Processes at the LHC

When several sparticle masses are known, the kinematics of SUSY decay processes observed at the LHC can be solved if the cascade decays contain sufficient steps. We demonstrate four examples of this full reconstruction technique applied to channels involving leptons, namely a) gluino mass determination, b) sbottom mass determination, c) LSP momentum reconstruction, and d) heavy higgs mass determination.

hep-ph↗

Measuring the Mass of the Lightest Chargino at the CERN LHC

Results are presented of a feasibility study of techniques for measuring the mass of the lightest chargino at the CERN LHC. These results suggest that for one particular mSUGRA model a statistically significant chargino signal can be identified and the chargino mass reconstructed with a precision of order 11% for of order 100 fb-1 of data.

hep-ph↗

The NAIAD experiment for WIMP searches at Boulby mine and recent results

The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at Boulby mine (UK) is described. The detector consists of an array of encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six crystals are collecting data at present. Data accumulated by four of them (10.6 kg x year exposure) have been used to set upper limits on the WIMP-nucleon spin-independent and WIMP-proton spin-dependent cross-sections. Pulse shape analysis has been applied to discriminate between nuclear recoils, as may be caused by WIMP interactions, and electron recoils due to gamma background. Various calibrations of crystals are presented.

hep-ex↗

Study and suppression of anomalous fast events in inorganic scintillators for dark matter searches

The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystals by alphas, probably from radon decay. A new array of unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure nitrogen atmosphere is under construction at Boulby. Such an approach allows complete control of the surface of the crystals and the ability to remove any surface contamination. First data from the unencapsulated NaI(Tl) do not show the presence of anomalous fast events.

hep-ex↗

Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon

Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40 keV - 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estimator of the decay time constant for 6 keV < Eee < 30 keV nuclear recoil events is equal to 21.0 ns +/- 0.5 ns. It is observed that for electron recoils T0 rises slowly with energy, having a value ~ 30 ns at Eee ~ 15 keV. Electron and nuclear recoil pulse-shapes are found to be well fitted by single exponential functions although some evidence is found for a double exponential form for the nuclear recoil pulse-shape.

hep-ex↗

Measuring the SUSY Mass Scale at the LHC

An effective mass scale Meffsusy for supersymmetric particles is defined and techniques for its measurement at the LHC discussed. Monte Carlo results show that, for jets + ETmiss events, a variable constructed from the scalar sum of the transverse momenta of all reconstructed jets together with ETmiss provides in most cases the most accurate model independent measurement of Meffsusy (intrinsic precision ~ 2.1 % for mSUGRA models). The overall precision with which Meffsusy could be measured after given periods of LHC running and for given classes of SUSY models is calculated. The technique is extended to measurements of the total SUSY particle production cross section sigmasusy.

hep-ph↗

CsI(Tl) for WIMP dark matter searches

We report a study of CsI(Tl) scintillator to assess its applicability in experiments to search for dark matter particles. Measurements of the mean scintillation pulse shapes due to nuclear and electron recoils have been performed. We find that, as with NaI(Tl), pulse shape analysis can be used to discriminate between electron and nuclear recoils down to 4 keV. However, the discrimination factor is typically (10-15)% better than in NaI(Tl) above 4 keV. The quenching factor for caesium and iodine recoils was measured and found to increase from 11% to ~17% with decreasing recoil energy from 60 to 12 keV. Based on these results, the potential sensitivity of CsI(Tl) to dark matter particles in the form of neutralinos was calculated. We find an improvement over NaI(Tl) for the spin independent WIMP-nucleon interactions up to a factor of 5 assuming comparable electron background levels in the two scintillators.

hep-ex↗