Searcharxiv⌕ Search

arXiv subjects

D. Sarenac

Publications and source records attributed to D. Sarenac.

33 records · Page 2Linked to original sources

The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector

The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.

physics.ins-det↗

Measurement of the Antineutrino Spectrum from $^{235}$U Fission at HFIR with PROSPECT

This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to $^{235}$U. Despite broad agreement, comparison of the Huber $^{235}$U model to the measured spectrum produces a $χ^2/ndf = 51.4/31$, driven primarily by deviations in two localized energy regions. The measured $^{235}$U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\overline{ν_{e}}$ energy region of 5-7MeV.

nucl-ex↗

Generation and detection of spin-orbit coupled neutron beams

Spin-orbit coupling of light has come to the fore in nano-optics and plasmonics, and is a key ingredient of topological photonics and chiral quantum optics. We demonstrate a basic tool for incorporating analogous effects into neutron optics: the generation and detection of neutron beams with coupled spin and orbital angular momentum. $^3$He neutron spin-filters are used in conjunction with specifically oriented triangular coils to prepare neutron beams with lattices of spin-orbit correlations, as demonstrated by their spin-dependant intensity profiles. These correlations can be tailored to particular applications, such as neutron studies of topological materials.

quant-ph↗

A Low Mass Optical Grid for the PROSPECT Reactor Antineutrino Detector

PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of $\overlineν_e$ interactions in the detector. This paper is the technical reference for this PROSPECT subsystem, describing its design, fabrication, quality assurance, transportation and assembly in detail. In addition, the dimensional, optical and mechanical characterizations of optical grid components and the assembled PROSPECT target are also presented. The technical information and characterizations detailed here will inform geometry-related inputs for PROSPECT physics analysis, and can guide a variety of future particle detection development efforts, such as those using optically reflecting materials or filament-based 3D printing.

physics.ins-det↗

Lithium-loaded Liquid Scintillator Production for the PROSPECT experiment

This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.

physics.ins-det↗

Coherence Optimization in Neutron Interferometry through Defocussing

A zero-area four-blade perfect crystal neutron interferometer (NI) possess a decoherence-free subspace (DFS) for low-frequency mechanical vibrations and thus is easier to site. %has the potential to broaden the application of crystal-based neutron interferometry to a higher number of neutron sources. However, unlike the standard three-blade Mach-Zehnder NI the ideal contrast of this four-blade NI geometry is less than one. By applying a recently introduced quantum information model for dynamical diffraction we show that the contrast for the four-blade DFS NI can be increased by offsetting the focusing condition. The contrast optimization leads to an NI geometry where the distances between the centers of the blades are equidistant. An experiment is proposed to verify the increase in contrast.

quant-ph↗

Optimization of neutron diffraction from phase-gratings

The recent development of phase-grating moiré neutron interferometry promises a wide range of impactful experiments from dark-field imaging of material microstructure to precise measurements of fundamental constants. However, the contrast of 3 % obtained using this moiré interferometer was well below the theoretical prediction of 30 % using ideal gratings. It is suspected that non-ideal aspects of the phase-gratings was a leading contributor to this deficiency and that phase-gratings needed to be quantitatively assessed and optimized. Here we characterize neutron diffraction from phase-gratings using Bragg diffraction crystals to determine the optimal phase-grating orientations. We show well-defined diffraction peaks and explore perturbations to the diffraction peaks and the effects on interferometer contrast as a function of grating alignment. This technique promises to improve the contrast of the grating interferometers by providing in-situ aides to grating alignment.

physics.ins-det↗

First search for short-baseline neutrino oscillations at HFIR with PROSPECT

This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of $^{235}$U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor Oscillation and Spectrum Experiment, consists of a segmented 4 ton $^6$Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 meter water equivalent overburden. Data collected during 33 live-days of reactor operation at a nominal power of 85 MW yields a detection of 25461 $\pm$ 283 (stat.) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5$σ$ statistical significance within two hours of on-surface reactor-on data-taking. A reactor-model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the Reactor Antineutrino Anomaly at 2.2$σ$ confidence level.

hep-ex↗

Sub-micrometer resolution neutron tomography

We demonstrate a neutron tomography technique with sub-micrometer spatial resolution. Our method consists of measuring neutron diffraction spectra using a double crystal diffractometer as a function of sample rotation and then using a phase retrieval algorithm followed by tomographic reconstruction to generate a density map of the sample. In this first demonstration, silicon phase-gratings are used as samples, the periodic structure of which allows the shape of the gratings to be imaged without the need of position sensitive detectors. Topological features found in the reconstructions also appear in scanning electron micrographs. The reconstructions have a resolution of about 300 nm, which is over an order of magnitude smaller than the resolution of radiographic, phase contrast, differential phase contrast, and dark field neutron tomography methods. Further optimization of the underlying phase recovery and tomographic reconstruction algorithm is also considered.

physics.ins-det↗

Methods for preparation and detection of neutron spin-orbit states

The generation and control of neutron orbital angular momentum (OAM) states and spin correlated OAM (spin-orbit) states provides a powerful probe of materials with unique penetrating abilities and magnetic sensitivity. We describe techniques to prepare and characterize neutron spin-orbit states, and provide a quantitative comparison to known procedures. The proposed detection method directly measures the correlations of spin state and transverse momentum, and overcomes the major challenges associated with neutrons, which are low flux and small spatial coherence length. Our preparation techniques, utilizing special geometries of magnetic fields, are based on coherent averaging and spatial control methods borrowed from nuclear magnetic resonance. The described procedures may be extended to other probes such as electrons and electromagnetic waves.

quant-ph↗

Generation of a lattice of spin-orbit beams via coherent averaging

We describe a highly robust method, applicable to both electromagnetic and matter-wave beams, that can produce a beam consisting of a lattice of orbital angular momentum (OAM) states coupled to a two-level system. We also define efficient protocols for controlling and manipulating the lattice characteristics. These protocols are applied in an experimental realization of a lattice of optical spin-orbit beams. The novel passive devices we demonstrate here are also a natural alternative to existing methods for producing single-axis OAM and spin-orbit beams. Our techniques provide new tools for investigations of chiral and topological materials with light and particle beams.

physics.optics↗

Three Phase-Grating Moire Neutron Interferometer for Large Interferometer Area Applications

We demonstrate a three phase-grating neutron interferometer as a robust candidate for large area interferometry applications and characterization of materials. This novel far-field moire technique allows for broad wavelength acceptance and relaxed requirements related to fabrication and alignment, circumventing the main obstacles associated with perfect crystal neutron interferometry. Interference fringes were observed with a total interferometer length of four meters, and the effects of an aluminum 6061 alloy sample on the coherence of the system was examined. Experiments to measure the autocorrelation length of samples and the universal gravitational constant are proposed and discussed.

physics.ins-det↗

Noise Refocusing in a Five-blade Neutron Interferometer

We provide a quantum information description of a proposed five-blade neutron interferometer geometry and show that it is robust against low frequency mechanical vibrations and dephasing due to the dynamical phase. The extent to which the dynamical phase affects the contrast in a neutron interferometer is experimentally shown. In our model, we consider the coherent evolution of a neutron wavepacket in an interferometer crystal blade and simulate the effect of mechanical vibrations and momentum spread of the neutron through the interferometer. The standard three-blade neutron interferometer is shown to be immune to dynamical phase noise but prone to noise from mechanical vibrations, the decoherence free subspace four-blade neutron interferometer is shown to be immune to mechanical vibration noise but prone to noise from the dynamical phase, while the proposed five-blade neutron interferometer is shown to be immune to both low-frequency mechanical vibration noise and dynamical phase noise.

quant-ph↗

Quantum Information Approach to Dynamical Diffraction Theory

We present a simplified model for dynamical diffraction of particles through a periodic thick perfect crystal based on repeated application of a coherent beam splitting unitary at coarse-grained lattice sites. By demanding translational invariance and a computationally tractable number of sites in the coarse-graining we show how this approach reproduces many results typical of dynamical diffraction theory and experiments. This approach has the benefit of being applicable in the thick, thin, and intermediate crystal regimes. The method is applied to a three-blade neutron interferometer to predict the output beam profiles, interference patterns, and contrast variation.

quant-ph↗

Neutron Limit on the Strongly-Coupled Chameleon Field

The physical origin of the dark energy that causes the accelerated expansion rate of the universe is one of the major open questions of cosmology. One set of theories postulates the existence of a self-interacting scalar field for dark energy coupling to matter. In the chameleon dark energy theory, this coupling induces a screening mechanism such that the field amplitude is nonzero in empty space but is greatly suppressed in regions of terrestrial matter density. However measurements performed under appropriate vacuum conditions can enable the chameleon field to appear in the apparatus, where it can be subjected to laboratory experiments. Here we report the most stringent upper bound on the free neutron-chameleon coupling in the strongly-coupled limit of the chameleon theory using neutron interferometric techniques. Our experiment sought the chameleon field through the relative phase shift it would induce along one of the neutron paths inside a perfect crystal neutron interferometer. The amplitude of the chameleon field was actively modulated by varying the millibar pressures inside a dual-chamber aluminum cell. We report a 95% confidence level upper bound on the neutron-chameleon coupling $β$ ranging from $β< 4.7\times 10^6$ for a Ratra-Peebles index of n = 1 in the nonlinear scalar field potential to $β< 2.4\times 10^7$ for n = 6, one order of magnitude more sensitive than the most recent free neutron limit for intermediate n. Similar experiments can explore the full parameter range for chameleon dark energy in the foreseeable future.

astro-ph.CO↗