SearcharxivSearch

arXiv subjects

D. Stramaccioni

Publications and source records attributed to D. Stramaccioni.

3 recordsLinked to original sources

Euclid Structural-Thermal-Optical Performance

The Euclid system performance is defined in terms of image quality metrics tuned to the weak gravitational lensing (WL) cosmological probe. WL induces stringent requirements on the shape and stability of the VIS instrument system point spread function (PSF). The PSF is affected by error contributions from the telescope, the focal plane and image motion, and is controlled by a global error budget with error allocations to each contributor. Aims. During spacecraft development, we verified through a structural-thermal-optical performance (STOP) analysis that the built and verified telescope with its spacecraft interface meets the in-orbit steady-state and transient image quality requirements. Methods. For the purposes of the STOP analysis, a detailed finite-element mathematical model was set up and a standard set of test cases, both steady-state and transient, was defined, comprising combinations of worst-case boundary conditions. Results. The STOP analysis addressed the interaction of all spacecraft components in transmitting temperature-induced loads that lead to optical train deformation. The results of the prelaunch analysis demonstrated that temperature-induced optical perturbations will be well below the allowable limits for all permitted observing conditions. During the first year in orbit, we used the STOP analysis predictions to help interpret the measured performance as a function of environmental variables. Unpredicted disturbances were discovered and unexpected sensitivities were revealed. In-orbit temperature variations are small (<300 mK) and so are their effects on the telescope structure, but they are detected in the time histories of the image quality metrics and are a non-negligible factor in the PSF stability budget demanded by the WL science. Taking everything into account, our analysis confirms the excellent overall performance of the telescope.

astro-ph.IM

Fusion of 12C+28Si at deep sub-barrier energies

The existence of fusion hindrance is not well established in light heavy-ion systems. Studying slightly heavier cases allows extrapolating the trend to light systems of astrophysical interest. Fusion of 12C + 28Si has been measured down to deep sub-barrier energies, using 28Si beams from the XTU Tandem accelerator of LNL on thin 12C targets. The fusion-evaporation residues were detected by a detector telescope following an electrostatic beam separator, and coincidences between the gamma-ray array AGATA and segmented silicon detectors DSSD were performed, where the evaporated light charged particles were identified by pulse shape analysis. Fusion cross sections have been obtained in the wide range 150 mb-42 nb. Coupled-channel (CC) calculations using a Woods-Saxon potential reproduce the data above 0.1 mb. Below that, hindrance shows up and the CC results overestimate the cross sections which get close to the one-dimensional potential tunnelling limit. This suggests that the coupling strengths gradually vanish, as predicted by the adiabatic model. The hindrance threshold follows a recently updated phenomenological systematics.

nucl-ex

Clarifying the Radiative Decay of the Hoyle State with Charged-Particle Spectroscopy

A detailed knowledge of the decay properties of the so called Hoyle state in the $^{12}$C nucleus ($E_x=7.654$ MeV, $0^+$) is required to calculate the rate at which carbon is forged in typical red-giant stars. This paper reports on a new almost background-free measurement of the radiative decay branching ratio of the Hoyle state using advanced charged particle coincidence techniques. The exploitation, for the first time in a similar experiment, of a bidimensional map of the coincidence efficiency allows to reach an unitary value and, consequently, to strongly reduce sources of systematic uncertainties. The present results suggest a value of the radiative branching ratio of $Γ_{rad}/Γ_{tot}=4.2(6)\cdot10^{-4}$. This finding helps to resolve the tension between recent data published in the literature.

nucl-ex