SearcharxivSearch

arXiv subjects

D. Torres Machado

Publications and source records attributed to D. Torres Machado.

8 recordsLinked to original sources

Characterization of the background spectrum in DAMIC at SNOLAB

We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy and depth distributions of the observed ionization events to differentiate and constrain possible background sources, for example, bulk $^{3}$H from silicon cosmogenic activation and surface $^{210}$Pb from radon plate-out. We observe the bulk background rate of the DAMIC at SNOLAB CCDs to be as low as $3.1 \pm 0.6$ counts kg$^{-1}$ day$^{-1}$ keV$_{\text{ee}}^{-1}$, making it the most sensitive silicon dark matter detector. Finally, we discuss the properties of a statistically significant excess of events over the background model with energies below 200 eV$_{\text{ee}}$.

hep-ex

Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB

We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV$c^{-2}$. We also present new constraints on hidden-photon dark matter with masses in the range $1.2$-$30$ eV$c^{-2}$.

astro-ph.CO

First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB

We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.

astro-ph.CO

Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB

We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.

astro-ph.CO

Measurement of the ionization produced by sub-keV silicon nuclear recoils in a CCD dark matter detector

We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a $^{124}$Sb-$^{9}$Be photoneutron source, and their ionization signal is measured down to 60 eV electron equivalent. This energy range, previously unexplored, is relevant for the detection of low-mass dark matter particles. The measured efficiency is found to deviate from the extrapolation to low energies of the Lindhard model. This measurement also demonstrates the sensitivity to nuclear recoils of CCDs employed by DAMIC, a dark matter direct detection experiment located in the SNOLAB underground laboratory.

astro-ph.IM

Status of the DAMIC direct dark matter search experiment

The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This contribution discusses the installation progress, new calibration efforts near the threshold, a preliminary result with 2014 data, and the prospects for physics results after one year of data taking.

physics.ins-det

The DAMIC dark matter experiment

The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c$^2$. Previous results have demonstrated the potential of this technology, motivating the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. In this contribution, the mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds will be discussed, as well as physics results after one year of data taking.

physics.ins-det

Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment

We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, with an upper limit on the $^{238}$U ($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also searched for pairs of spatially correlated electron tracks separated in time by up to tens of days, as expected from $^{32}$Si-$^{32}$P or $^{210}$Pb-$^{210}$Bi sequences of $β$ decays. The decay rate of $^{32}$Si was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was obtained independently by $α$ spectroscopy and the $β$ decay sequence search. These levels of radioactive contamination are sufficiently low for the successful operation of CCDs in the forthcoming 100 g DAMIC detector.

astro-ph.IM