Modeling Light Signals Using Data from the First Pulsed Neutron Source Program at the DUNE Vertical Drift ColdBox Test Facility at CERN Neutrino Platform

In this paper, we present a first quantitative test of detected light signals produced in a pulsed neutron source run in a small vertical drift LArTPC at the CERN neutrino platform ColdBox test facility. The ColdBox cryostat, detectors, neutron sources, and particle interactions are modeled and simulated using Fluka. A good agreement is found in the detected number of photoelectrons, with values below 650 photoelectrons in both data and simulation, for all four X-ARAPUCA photodetectors on the cathode in the LArTPC. A time constant is also fitted from the neutron-beam-off light signal spectrum and found consistent between data and MC. Several important systematic effects are discussed and serve as guides for future runs at larger LArTPCs.

hep-ex

Characterization and Novel Application of Power Over Fiber for Electronics in a Harsh Environment

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at $\sim$ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R$\&$D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency, and superior isolation.

physics.ins-det

LArQL: A phenomenological model for treating light and charge generation in liquid argon

Experimental data shows that both ionization charge and scintillation light in LAr depend on the deposited energy density ($dE/dx$) and electric field ($\mathcal{E}$). Moreover, free ionization charge and scintillation light are anticorrelated, complementary at a given ($dE/dx$, $\mathcal{E}$) pair. We present LArQL, a phenomenological model that provides the anticorrelation between light and charge and its dependence on the deposited energy as well as on the electric field applied. It modifies the Birks' charge model considering the contribution from the escape electrons at null and low electric fields, and reconciles with Birks' model prediction at higher fields. Deviations from current Birks' model are observed for LArTPCs operating at low $\mathcal{E}$ and for heavily ionizing particles. The LArQL model presents a satisfactory description at $dE/dx$ and field ranges for interacting particles in LArTPCs and fits well the available data. Improvements via data sets compilation and global fits are also interesting features of the model.

physics.ins-det

Measurement of the ($π^-$, Ar) total hadronic cross section at the LArIAT experiment

We present the first measurement of the negative pion total hadronic cross section on argon, which we performed at the Liquid Argon In A Testbeam (LArIAT) experiment. All hadronic reaction channels, as well as hadronic elastic interactions with scattering angle greater than 5~degrees are included. The pions have a kinetic energies in the range 100-700~MeV and are produced by a beam of charged particles impinging on a solid target at the Fermilab Test Beam Facility. LArIAT employs a 0.24~ton active mass Liquid Argon Time Projection Chamber (LArTPC) to measure the pion hadronic interactions. For this measurement, LArIAT has developed the ``thin slice method", a new technique to measure cross sections with LArTPCs. While generally higher than the prediction, our measurement of the ($π^-$,Ar) total hadronic cross section is in agreement with the prediction of the Geant4 model when considering a model uncertainty of $\sim$5.1\%.

hep-ex

Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar

In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N2, O2, and H2O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.

physics.ins-det

The Liquid Argon In A Testbeam (LArIAT) Experiment

The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.

physics.ins-det

Increasing the efficiency of photon collection in LArTPCs: the ARAPUCA light trap

The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial role in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation studies. In this contribution, we present the current R&D work on the ARAPUCA (Argon R&D Advanced Program at UNICAMP), a light trap device to enhance Ar scintillation light collection and thus the overall performance of LArTPCs. The ARAPUCA working principle is based on a suitable combination of dichroic filters and wavelength shifters to achieve a high efficiency in light collection. We discuss the operational principles, the last results of laboratory tests and the application of the ARAPUCA as the alternative photon detection system in the protoDUNE detector.