SearcharxivSearch

arXiv subjects

D. Tourres

Publications and source records attributed to D. Tourres.

At least 19 recordsLinked to original sources

First Dark Photon Search Results from the Dandelion Experiment

This paper presents the first results from the Dandelion experiment, a directional detection, which searches for 1 meV dark photon dark matter. We use a spherical mirror to convert dark photons into standard millimeter-wavelength photons that can then be detected with an array of 221 Kinetic Inductance Detectors (KIDs) cooled down to 150 mK within the KISS-NIKA camera ( (KIDs Interferometric Spectral Surveyor) and operating between 150 and 350 GHz. We used 1480 minutes of data to search for the signal of dark photons in the KID detectors, which is expected to be modulated due to the Earth's rotation. Our main challenge was to deal with a large background from room temperature and stray-light fluctuations. We used a de-correlation analysis to remove these background fluctuations. Templates of the background fluctuations were constructed from a Principal Component Analysis decomposition of detector measurements outside the expected Field of View trajectory of dark photons. We found that the dark photon signal was consistent with zero, giving a new upper limit on the dark photon's kinetic mixing, $\chi$, with masses between 0.6 meV and 1.4 meV. These are the first constraints on dark photons as a dark matter candidate using an array of KIDs at millimeter wavelength.

astro-ph.CO

CONCERTO: forward modeling of interferograms for calibration

The CarbON [CII] line in post-rEionisation and ReionisaTiOn epoch (CONCERTO) instrument is a low-resolution mapping Fourier-transform spectrometer, based on lumped-element kinetic inductance detector (LEKID) technology, operating at 130- 310 GHz. It was installed on the 12-meter APEX telescope in Chile in April 2021 and operated until December 2022. CONCERTO's main science goal is to constrain the [CII] line fluctuations at high redshift. To reach that goal CONCERTO observed 1.4 deg2 in the COSMOS field. To ensure accurate calibration of the data, we have developed a forward model capable of simulating both the spectral response and the corresponding interferograms for each scan of observation in the COSMOS field. We present the modeling approach that enables us to reproduce the expected instrument outputs under controlled input conditions and provides a framework for the different calibration steps, including the absolute brightness calibration of the spectra. We constructed a dedicated analysis pipeline to characterize the raw interferometric data (interferograms) obtained under a broad range of atmospheric conditions at APEX. Using the forward model, we measured the interferogram alignment with the optical path difference (zero path difference, ZPD) and the relative response of each KID (flatfield). Together, these elements enable a robust characterization of the instrument's spectral brightness calibration.

astro-ph.IM

KISS: instrument description and performance

Kinetic inductance detectors (KIDs) have been proven as reliable systems for astrophysical observations, especially in the millimetre range. Their compact size enables to optimally fill the focal plane, thus boosting sensitivity. The KISS (KIDs Interferometric Spectral Surveyor) instrument is a millimetre camera that consists of two KID arrays of 316 pixels each coupled to a Martin-Puplett interferometer (MPI). The addition of the MPI grants the KIDs camera the ability to provide spectral information in the 100 and 300 GHz range. In this paper we report the main properties of the KISS instrument and its observations. We also describe the calibration and data analysis procedures used. We present a complete model of the observed data including the sky signal and several identified systematics. We have developed a full photometric and spectroscopic data analysis pipeline that translates our observations into science-ready products. We show examples of the results of this pipeline on selected sources: Moon, Jupiter and Venus. We note the presence of a deficit of response with respect to expectations and laboratory measurements. The detectors noise level is consistent with values obtained during laboratory measurements, pointing to a sub-optimal coupling between the instrument and the telescope as the most probable origin for the problem. This deficit is large enough as to prevent the detection of galaxy clusters, which were KISS main scientific objective. Nevertheless, we have demonstrated the feasibility of this kind of instrument, in the prospect for other KID interferometers (such as the CONCERTO instrument). As this regard, we have developed key instrumental technologies such as optical conception, readout electronics and raw calibration procedures, as well as, adapted data analysis procedures.

astro-ph.IM

CONCERTO at APEX -- On-sky performance in continuum

We present the data-processing algorithms and the performance of CONCERTO (CarbON CII line in post-rEionisation and ReionisaTiOn epoch) in continuum by analysing the data from the commissioning and scientific observations. The beam pattern is characterized by an effective FWHM of 31.9 $\pm$ 0.6" and 34.4 $\pm$ 1.0" for high-frequency (HF) and low-frequency (LF) bands. The main beam is slightly elongated with a mean eccentricity of 0.46. Two error beams of $\sim$65" and $\sim$130" are characterized, enabling the estimate of a main beam efficiency of $\sim$0.52. The field of view is accurately reconstructed and presents coherent distortions between the HF and LF arrays. LEKID parameters were robustly determined for 80% of the read tones. Cross-talks between LEKIDs are the first cause of flagging, followed by an excess of eccentricity for $\sim$10% of the LEKIDs, all located in a given region of the field of view. On the 44 scans of Uranus selected for the absolute photometric calibration, 72.5% and 78.2% of the LEKIDs are selected as valid detectors with a probability >70%. By comparing Uranus measurements with a model, we obtain calibration factors of 19.5$\pm$0.6 [Hz/Jy] and 25.6$\pm$0.9 [Hz/Jy] for HF and LF. The point-source continuum measurement uncertainties are 3.0% and 3.4% for HF and LF bands. The RMS of CONCERTO maps is verified to evolve as proportional to the inverse square root of integration time. The measured NEFDs for HF and LF are 115$\pm$2 mJy/beam$\cdot$s$^{1/2}$ and 95$\pm$1 mJy/beam$\cdot$s$^{1/2}$, obtained using CONCERTO data on the COSMOS field for a mean precipitable water vapour and elevation of 0.81 mm and 55.7 deg. CONCERTO demonstrates unique capabilities in fast dual-band spectral mapping with a $\sim$18.5' instantaneous field-of-view. CONCERTO's performance in continuum is perfectly in line with expectations.

astro-ph.IM

Design,fabrication and characterization of 8x9 n-type silicon pad array for sampling calorimetry

This paper reports the development and testing of n-type silicon pad array detectors targeted for the Forward Calorimeter (FoCal) detector, which is an upgrade of the ALICE detector at CERN, scheduled for data taking in Run~4~(2029-2034). The FoCal detector includes hadronic and electromagnetic calorimeters, with the latter made of tungsten absorber layers and granular silicon pad arrays read out using the High Granularity Calorimeter Readout Chip~(HGCROC). This paper covers the Technology Computer-Aided Design (TCAD) simulations, the fabrication process, current versus voltage (IV) and capacitance versus voltage (CV) measurements, test results with a blue LED and $^{90}$Sr beta source, and neutron radiation hardness tests. IV measurements for the detector showed that 90\% of the pads had leakage current below 10~nA at full depletion voltage. Simulations predicted a breakdown voltage of 1000~V and practical tests confirmed stable operation up to 500~V without breakdown. CV measurements in the data and the simulations gave a full depletion voltage of around 50~V at a capacitance of 35~pF. LED tests verified that all detector pads responded correctly. Additionally, the 1$\times$1 cm$^2$ pads were also tested with the neutron radiations at a fluence of $5\times10^{13}$ 1~MeV~n$_{eq}$/cm$^2$.

physics.ins-det

Beam test of n-type Silicon pad array detector at PS CERN

This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrm{\eta}$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored region of low momentum fraction x ($\mathrm{\sim10^{-5} - 10^{-6}}$). The prototype is a $\mathrm{8\times9}$ n-type Si pad array detector with each pad occupying one cm$^2$ area, fabricated on a 6-in, 325~$\mathrm{\pm 10 \thinspace \mu}$m thick, and high-resistivity ($\sim$7 k$\Omega \thinspace$ cm) Si wafer which is readout using HGCROCv2 chip. The detector is tested using pion beams of energy 10~GeV and electron beams of energy 1-5~GeV. The measurements of the Minimum Ionizing Particle (MIP) response of pions and the shower profiles of electrons are reported.

physics.ins-det

Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter

We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$\lambda_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS and SPS beam lines with hadron (electron) beams up to energies of 350 (300) GeV. Regarding FoCal-E, we report a comprehensive analysis of its response to minimum ionizing particles across all pad layers. The longitudinal shower profile of electromagnetic showers is measured with a layer-wise segmentation of 1$X_0$. As a projection to the performance of the final detector in electromagnetic showers, we demonstrate linearity in the full energy range, and show that the energy resolution fulfills the requirements for the physics needs. Additionally, the performance to separate two-showers events was studied by quantifying the transverse shower width. Regarding FoCal-H, we report a detailed analysis of the response to hadron beams between 60 and 350 GeV. The results are compared to simulations obtained with a Geant4 model of the test beam setup, which in particular for FoCal-E are in good agreement with the data. The energy resolution of FoCal-E was found to be lower than 3% at energies larger than 100 GeV. The response of FoCal-H to hadron beams was found to be linear, albeit with a significant intercept that is about factor 2 larger than in simulations. Its resolution, which is non-Gaussian and generally larger than in simulations, was quantified using the FWHM, and decreases from about 16% at 100 GeV to about 11% at 350 GeV. The discrepancy to simulations, which is particularly evident at low hadron energies, needs to be further investigated.

physics.ins-det

Tests at 2K of the beta 0.35 spoke cryomodule prototype with the MTCA.4-based Low Level RF system prototype for the MYRRHA R&D

Within the framework of the first phase of MYRRHA (Multi-purpose hYbrid Research Reactor for High-tech Applications) project, called MINERVA, IJCLab was in charge of a fully equipped Spoke cryomodule prototype development, tested at 2K. It integrates two superconducting single spoke cavities, the RF power couplers and the Cold Tuning Systems associated. On the control side, a MTCA.4-based Low Level Radio Frequency (LLRF) system prototype and the Software/EPICS developments has been realized by IJCLab and the SCK CEN in collaboration with the company IOxOS Technologies. The final version of the global system and the results of the tests at 2K will show with some perspectives.

physics.acc-ph

Prototype electronics for the silicon pad layers of the future Forward Calorimeter (FoCal) of the ALICE experiment at the LHC

A Forward Calorimeter (FoCal) has been proposed as part of the ALICE upgrades for data taking from 2029 onwards. The FoCal will feature a sampling electromagnetic calorimeter segmented into 110 towers supplemented by a hadron calorimeter. The electromagnetic calorimeter will be composed of 20 passive layers of tungsten absorber interleaved with 18 active layers of low-granularity silicon pad sensors and two layers of high-granularity pixel detectors. Each pad layer will be read out by 110 silicon pad sensors of 72 channels, amounting to a total of 1980 sensors. This paper describes, from front-end to back-end, the electronics developed to instrument a tower prototype composed of 18 silicon pad sensors as well as a design proposal for the full-detector readout system.

physics.ins-det

CONCERTO: Readout and control electronics

The CONCERTO spectral-imaging instrument was installed at the Atacama Pathfinder EXperiment (APEX) 12-meter telescope in April 2021. It has been designed to look at radiation emitted by ionised carbon atoms, [CII], and use the "intensity Mapping" technique to set the first constraints on the power spectrum of dusty star-forming galaxies. The instrument features two arrays of 2152 pixels constituted of Lumped Element Kinectic Inductance Detectors (LEKID) operated at cryogenic temperatures, cold optics and a fast Fourier Transform Spectrometer (FTS). To readout and operate the instrument, a newly designed electronic system hosted in five microTCA crates and composed of twelve readout boards and two control boards was designed and commissioned. The architecture and the performances are presented in this paper.

astro-ph.IM

Observations with KIDs Interferometer Spectrum Survey(KISS)

We describe the preliminary on-sky results of the KIDs Interferometer Spectrum Survey (KISS), a spectral imager with a 1 deg field of view (FoV). The instrument operates in the range 120-180 GHz from the 2.25 m Q-U-I JOint TEnerife telescope in Teide Observatory (Tenerife, Canary Islands), at 2 395 m altitude above sea level. Spectra at low resolution, up to 1.45 GHz, are obtained using a fast (3.72 Hz mechanical frequency) Fourier transform spectrometer, coupled to a continuous dilution cryostat with a stabilized temperature of 170 mK that hosts two 316-pixel arrays of lumped-element kinetic inductance detectors. KISS generates more than 3 000 spectra per second during observations and represents a pathfinder to demonstrate the potential for spectral mapping with large FoV. We give an overall description of the spectral mapping paradigm and we present recent results from observations, in this paper.

astro-ph.IM

CONCERTO at APEX: Installation and first phase of on-sky commissioning

CONCERTO (CarbON CII line in post-rEionisation and ReionisaTiOn) is a large field-of-view (FoV) spectro-imager that has been installed on the Cassegrain Cabin of Atacama Pathfinder EXperiment (APEX) telescope in April 2021. CONCERTO hosts 2 focal planes and a total number of 4000 Kinetic Inductance Detectors (KID), with an instantaneous FoV of 18.6 arcminutes in the range of 130-310 GHz. The spectral resolution can be easily tuned down to 1 GHz depending on the scientific target. The scientific program of CONCERTO has many objectives, with two main programs focused on mapping the fluctuations of the [CII] line intensity in the reionisation and post-reionisation epoch (4.5<z<8.5), and on studying galaxy clusters via the thermal and kinetic Sunyaev-Zel'dovich (SZ) effect. CONCERTO will also measure the dust and molecular gas contents of local and intermediate-redshift galaxies, it will study the Galactic star-forming clouds and finally it will observe the CO intensity fluctuations arising from 0.3<z<2 galaxies. The design of the instrument, installation at APEX and current status of the commissioning phase and science verification will be presented. Also we describe the deployment and first on-sky tests performed between April and June 2021.

astro-ph.IM

Accurate sky signal reconstruction for ground-based spectroscopy with kinetic inductance detectors

Context. Wide-field spectrometers are needed to deal with current astrophysical challenges that require multiband observations at millimeter wavelengths. An example of these is the KIDs Interferometer Spectrum Survey (KISS), which uses two arrays of kinetic inductance detectors (KIDs) coupled to a Martin-Puplett interferometer (MPI). KISS has a wide instantaneous field of view (1 deg in diameter) and a spectral resolution up to 1.45 GHz in the 120-180 GHz electromagnetic band. The instrument is installed on the 2.25 m Q-U-I JOint TEnerife telescope in Teide Observatory (Tenerife, Canary Islands), at an altitude of 2395 m above sea level. Aims. This work presents an original readout modulation method developed to improve the sky signal reconstruction accuracy for types of instruments for which a fast sampling frequency is required both to remove atmospheric fluctuations and to perform full spectroscopic measurements on each sampled sky position. Methods. We first demonstrate the feasibility of this technique using simulations. Then, we apply such a scheme to on-sky calibration. Results. We show that the sky signal can be reconstructed to better than 0.5% for astrophysical sources, and to better than 2% for large background variations such as in "skydip", in an ideal noiseless scenario. The readout modulation method is validated by observations on-sky during the KISS commissioning campaign. Conclusions. We conclude that accurate photometry can be obtained for future KID-based MPI.

astro-ph.IM

CONCERTO at APEX: installation and technical commissioning

We describe the deployment and first tests on Sky of CONCERTO, a large field-of-view (18.6arc-min) spectral-imaging instrument. The instrument operates in the range 130-310GHz from the APEX 12-meters telescope located at 5100m a.s.l. on the Chajnantor plateau. Spectra with R=1-300 are obtained using a fast (2.5Hz mechanical frequency) Fourier Transform Spectrometer (FTS), coupled to a continuous dilution cryostat with a base temperature of 60mK. Two 2152-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) are installed in the cryostat that also contains the cold optics and the front-end electronics. CONCERTO, installed in April 2021, generates more than 20k spectra per second during observations. We describe the final development phases, the installation and the first results obtained on Sky.

astro-ph.IM

A wide field-of-view low-resolution spectrometer at APEX: instrument design and science forecast

Characterise the large-scale structure in the Universe from present times to the high redshift epoch of reionisation is essential to constraining the cosmology, the history of star formation and reionisation, measuring the gas content of the Universe and obtaining a better understanding of the physical process that drive galaxy formation and evolution. Using the integrated emission from unresolved galaxies or gas clouds, line intensity mapping (LIM) provides a new observational window to measure the larger properties of structure. This very promising technique motivates the community to plan for LIM experiments. We describe the development of a large field-of-view instrument, named CONCERTO, operating in the range 130-310 GHz from the APEX 12-meters telescope. CONCERTO is a low-resolution spectrometer based on the Lumped Element Kinetic Inductance Detectors technology. Spectra are obtained using a fast Fourier Transform Spectrometer (FTS), coupled to a dilution cryostat with base temperature of 0.1K. Two 2 kilo-pixels arrays of LEKID are mounted inside the cryostat that also contains the cold optics and the front-end electronics. We present in detail the technological choices leading to the instrumental concept, together with the design and fabrication of the instrument and preliminary laboratory tests on the detectors. We also give our best estimates of CONCERTO sensitivity and give predictions for two of the main scientific goals of CONCERTO, i.e. a [CII]-intensity mapping survey and observations of galaxy clusters. We provide a detail description of the instrument design. Based on realistic comparisons with existing instruments developed by our group (NIKA, NIKA2, and KISS), and on laboratory detectors characterisation, we provide an estimate of CONCERTO sensitivity on sky. Finally, we describe in detail two out of the main science goals offered by CONCERTO at APEX.

astro-ph.IM

The KISS experiment

Mapping millimetre continuum emission has become a key issue in modern multi-wavelength astrophysics. In particular, spectrum-imaging at low frequency resolution is an asset for characterizing the clusters of galaxies via the Sunyaev Zeldovich (SZ) effect. In this context, we have built a ground-based spectrum-imager named KIDs Interferometer Spectrum Survey (KISS). This instrument is based on two 316-pixel arrays of Kinetic Inductance Detectors (KID) cooled to 150 mK by a custom dilution refrigerator-based cryostat. By using Ti-Al and Al absorbers, we can cover a wide frequency range between 80 and 300 GHz. In order to preserve a large instantaneous Field of View (FoV) 1 degree the spectrometer is based on a Fourier Transform interferometer. This represents a technological challenge due to the fast scanning speed that is needed to overcome the effects of background atmospheric fluctuations. KISS is installed at the QUIJOTE 2.25 m telescope in Tenerife since February 2019 and is currently in its commissioning phase. In this proceeding we present an overview of the instrument and the latest results.

astro-ph.IM

KISS: a spectrometric imager for millimetre cosmology

Clusters of galaxies are used to map the large-scale structures in the universe and as probe of universe evolution. They can be observed through the Sunyaev-Zel'dovich (SZ) effect. At this respect the spectro-imaging at low resolution frequency is an important tool, today, for the study of cluster of galaxies. We have developed KISS (KIDs-Interferometer-Spectrum-Survey), a spectrometric imager dedicated to the secondary anisotropies of the Cosmic Microwave Background (CMB). The multi-frequency approach permits to improve the component separation with respect to predecessor experiments. In this paper, firstly, we provide a description of the scientific context and the state of the art of SZ observations. Secondly, we describe the KISS instrument. Finally, we show preliminary results of the ongoing commissioning campaign.

astro-ph.IM

The STEREO Experiment

The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.

physics.ins-det