SearcharxivSearch

arXiv subjects

D. Trbojevic

Publications and source records attributed to D. Trbojevic.

14 recordsLinked to original sources

White Paper on a Novel FFA-Based CEBAF Upgrade to 22 GeV

We present a conceptual design for a cost-effective upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) to 22 GeV using non-scaling fixed-field alternating-gradient (FFA) arcs built from Halbach-style permanent magnets. Building on the eight-pass energy-recovery demonstration at the Cornell--BNL CBETA test accelerator, the design replaces the highest-energy recirculation arcs with a pair of FFA arcs that simultaneously transport six passes spanning a factor-of-two momentum range. We describe the machine layout; including the injector, recirculating linacs, spreaders and recombiners, FFA arcs, splitters, transition and extraction regions; together with beam-dynamics validation studies covering emittance growth, synchrotron-radiation-driven depolarization, and orbit correction, and we summarize permanent-magnet design, prototyping, and radiation-resiliency results. This white paper documents the accelerator physics underpinning a staged path to 22 GeV that preserves CEBAF's multi-hall, high-luminosity, polarized-beam capabilities.

physics.acc-ph

Measurement of the Per Cavity Energy Recovery Efficiency in the Single Turn CBETA Configuration

Prior to establishing operation of the world's first mulit-turn superconducting Energy Recovery Linac, (ERL) the Cornell-BNL Energy Recovery Test Accelerator (CBETA) was configured for one turn energy recovery. In this setup, direct measurement of the beam loading in each of the main linac cavities demonstrated high energy recovery efficiency. Specifically, a total one-turn power balance efficiency of 99.4%, with per cavity power balances ranging from 99.2-99.8%, was measured. When accounting for small particle losses occurring in the path length adjustment sections of the return loop, this corresponds to per cavity single particle energy recovery efficiencies ranging from 99.8 to 100.5%. A maximum current of 70 microamps was energy recovered, limited by radiation shielding of the beam stop in its preliminary installation.

physics.acc-ph

Beam Commissioning Results from the CBETA Fractional Arc Test

This work describes first commissioning results from the Cornell Brookhaven Energy Recovery Test Accelerator Fractional Arc Test. These include the recommissioning of the Cornell photo-injector, the first full energy operation of the main linac with beam, as well as commissioning of the lowest energy matching beamline (splitter) and a partial section of the Fixed Field Alternating gradient (FFA) return loop featuring first production Halbach style permanent magnets. Achieving these tasks required characterization of the injection beam, calibration and phasing of the main linac cavities, demonstration of the required 36 MeV energy gain, and measurement of the splitter line horizontal dispersion and R56 at the nominal 42 MeV. In addition, a procedure for determining the BPM offsets, as well as the tune per cell in the FFA section via scanning the linac energy and inducing betatron oscillations around the periodic orbit in the fractional arc was developed and tested. A detailed comparison of these measurements to simulation is discussed.

physics.acc-ph

CBETA Design Report, Cornell-BNL ERL Test Accelerator

This design report describes the construction plans for the world's first multi-pass SRF ERL. It is a 4-pass recirculating linac that recovers the beam's energy by 4 additional, decelerating passes. All beams are returned for deceleration in a single beam pipe with a large-momentum-aperture permanent magnet FFAG optics. Cornell University has been pioneering a new class of accelerators, Energy Recovery Linacs (ERLs), with a new characteristic set of beam parameters. Technology has been prototyped that is essential for any high brightness electron ERL. This includes a DC electron source and an SRF injector Linac with world-record current and normalized brightness in a bunch train, a high-current linac cryomodule, and a high-power beam stop, and several diagnostics tools for high-current and high-brightness beams. All these are now being used to construct a novel one-cryomodule ERL in Cornell's Wilson Lab. Brookhaven National Laboratory (BNL) has designed a multi-turn ERL for eRHIC, where beam is transported more than 20 times around the 4km long RHIC tunnel. The number of transport lines is minimized by using two arcs with strongly-focusing permanent magnets that can control many beams of different energies. A collaboration between BNL and Cornell has been formed to investigate this multi-turn eRHIC ERL design by building a 4-turn, one-cryomodule ERL at Cornell. It also has a return loop built with strongly focusing permanent magnets and is meant to accelerate 40mA beam to 150MeV. This high-brightness beam will have applications beyond accelerator research, in industry, in nuclear physics, and in X-ray science.

physics.acc-ph

Electron Ion Collider: The Next QCD Frontier - Understanding the glue that binds us all

This White Paper presents the science case of an Electron-Ion Collider (EIC), focused on the structure and interactions of gluon-dominated matter, with the intent to articulate it to the broader nuclear science community. It was commissioned by the managements of Brookhaven National Laboratory (BNL) and Thomas Jefferson National Accelerator Facility (JLab) with the objective of presenting a summary of scientific opportunities and goals of the EIC as a follow-up to the 2007 NSAC Long Range plan. This document is a culmination of a community-wide effort in nuclear science following a series of workshops on EIC physics and, in particular, the focused ten-week program on "Gluons and quark sea at high energies" at the Institute for Nuclear Theory in Fall 2010. It contains a brief description of a few golden physics measurements along with accelerator and detector concepts required to achieve them, and it benefited from inputs from the users' communities of BNL and JLab. This White Paper offers the promise to propel the QCD science program in the U.S., established with the CEBAF accelerator at JLab and the RHIC collider at BNL, to the next QCD frontier.

nucl-ex

eRHIC Design Study: An Electron-Ion Collider at BNL

This document presents BNL's plan for an electron-ion collider, eRHIC, a major new research tool that builds on the existing RHIC facility to advance the long-term vision for Nuclear Physics to discover and understand the emergent phenomena of Quantum Chromodynamics (QCD), the fundamental theory of the strong interaction that binds the atomic nucleus. We describe the scientific requirements for such a facility, following up on the community-wide 2012 white paper, 'Electron-Ion Collider: the Next QCD Frontier', and present a design concept that incorporates new, innovative accelerator techniques to provide a cost-effective upgrade of RHIC with polarized electron beams colliding with the full array of RHIC hadron beams. The new facility will deliver electron-nucleon luminosity of 10^33-10^34 cm-1sec-1 for collisions of 15.9 GeV polarized electrons on either 250 GeV polarized protons or 100 GeV/u heavy ion beams. The facility will also be capable of providing an electron beam energy of 21.2 GeV, at reduced luminosity. We discuss the on-going R&D effort to realize the project, and present key detector requirements and design ideas for an experimental program capable of making the 'golden measurements' called for in the EIC White Paper.

physics.acc-ph

The Investigations Of Beam Extraction And Collimation At U-70 Proton Synchrotron Of IHEP By Using Short Silicon Crystals

The new results of using short (2-4mm) bent crystals for extraction and collimation of proton beam at IHEP 70 Gev proton synchrotron are reported. A broad range of energies from 6 to 65 GeV has been studied in the same crystal collimation set-up. The efficiency of extraction more than 85% and intensity more than 10E12 were obtained by using crystal with the length 2-mm and the angle 1 mrad. The new regime of extraction is applied now at the accelerator to deliver the beam for different experimental setups within the range of intensity 10E7-10E12ppp.

hep-ex

Crystal experiments on efficient beam extraction

Silicon crystal was channeling and extracting 70-GeV protons from the U-70 accelerator with efficiency of 85.3+-2.8% as measured for a beam of 10^12 protons directed towards crystals of 2 mm length in spills of 1-2 s duration. The experimental data follow very well the prediction of Monte Carlo simulations. This success is important to devise a more efficient use of the U-70 accelerator in Protvino and provides a crucial support for implementation of crystal-assisted collimation of gold ion beam in RHIC and slow extraction from AGS onto E952, now in preparation at Brookhaven Nat'l Lab. Future applications, spanning in the energy from sub-GeV (medical) to order of 1 GeV (scraping in the SNS, extraction from COSY) to order of 1 TeV and beyond (scraping in the Tevatron, LHC, VLHC), can benefit from these studies.

hep-ex

Optimization of the parameters in the RHIC single crystal heavy ion collimation

In the framework of the project to design and test a collimation system prototype using bent channeling crystal for cleaning of the RHIC heavy ion beam halo, we have studied the optimal length and bending angle of a silicon (110) single crystal proposed to be a primary element situated upstream of the traditional heavy amorphous collimator. Besides the matters of the channeling and collimation efficiency, we also looked into the impact the crystal may have on the non-channeled particles that go on circulating in the ring, so as to reduce the momentum offset of the particles scattered of the crystal.

hep-ex

Crystal-based approach to beam collimation in RHIC and SNS

Bent crystal serving as a scraper of the beam collimation system can channel halo particles directly into the absorber. By means of computer simulations, we analyse the capabilities of crystal technique for the beam cleaning process. Two applications are considered: the crystal collimator now being installed into RHIC for cleaning of the fully stripped gold ions, and a similar system being developed for the Accumulator Ring of the Spallation Neutron Source.

hep-ex

Progress in crystal extraction and collimation

Recent IHEP Protvino experiments show efficiencies of crystal-assisted slow extraction and collimation of 85.3+-2.8%, at the intensities of the channeled beam on the order of 10^12 proton per spill of 2 s duration. The obtained experimental data well follows the theory predictions. We compare the measurements against theory and outline the theoretical potential for further improvement in the efficiency of the technique. This success is important for the efficient use of IHEP accelerator and for implementation of crystal-assisted collimation at RHIC and slow extraction from AGS onto E952, now in preparation. Future applications, spanning in the energy from order of 1 GeV (scraping in SNS, slow extraction from COSY and medical accelerators) to order of 1 TeV and beyond (scraping in Tevatron, LHC, VLHC), can benefit from these studies.

hep-ex

A study of RHIC crystal collimation

The Relativistic Heavy Ion Collider (RHIC) will experience increasing longitudinal and transverse heavy ion emittances, mostly due to intra-beam scattering (IBS). The experiments in RHIC are expected to not only have reduced luminosities due to IBS but also an unwanted beam halo. Primary betatron collimators will be used to remove the large amplitude particles. The efficiency of the primary collimator in RHIC depends very much on the alignment of the jaws which needs to be within few micro-radians for the best conditions. As proposed by V. Biryukov bent crystals could be used to improve the efficiency of an existing collimation system by installing them upstream of the collimator jaws. Bent crystals have been successfully used in SPS, Protvino and Fermilab for extraction of the beam particles channeled through them. This study examines possible improvements of the primary collimator system for heavy ions at RHIC by use of bent crystals. Bent crystals will reduce the collimator jaws alignment requirement and will increase collimator efficiency thereby reducing detector background.

hep-ex

Muon Collider Design

Muon Colliders have unique technical and physics advantages and disadvantages when compared with both hadron and electron machines. They should thus be regarded as complementary. Parameters are given of 4 TeV and 0.5 TeV high luminosity μ^+ μ^- colliders, and of a 0.5 TeV lower luminosity demonstration machine. We discuss the various systems in such muon colliders, starting from the proton accelerator needed to generate the muons and proceeding through muon cooling, acceleration and storage in a collider ring. Detector background, polarization, and nonstandard operating conditions are discussed.

acc-phys