SearcharxivSearch

arXiv subjects

D. Venos

Publications and source records attributed to D. Venos.

6 recordsLinked to original sources

Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project

The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source for a liquid noble gas dark matter experiment like the XENON project. However, the risk of contamination of the detector with traces of the much longer lived mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has been investigated. To do so, a cryogenic trap has been connected to the source for about 10 days, after which it was removed and probed for the strongest 83Rb gamma-rays with an ultra-sensitive Germanium detector. No signal has been found. The corresponding upper limit on the released 83Rb activity means that the investigated type of source can be used in the XENON project and similar low-background experiments as 83mKr generator without a significant risk of contaminating the detector. The measurements also allow to set upper limits on the possible release of the isotopes 84Rb and 86Rb, traces of which were created alongside the production of 83Rb at the Rez cyclotron.

astro-ph.IM

Magnetic moment of Ag-104(m) and the hyperfine magnetic field of Ag in Fe using nuclear magnetic resonance on oriented nuclei

Nuclear magnetic resonance (NMR/ON) measurements with beta- and gamma-ray detection have been performed on oriented Ag-104(g,m) nuclei with the NICOLE He-3-He-4 dilution refrigerator setup at ISOLDE/CERN. For Ag-104(g) (I-pi = 5(+)) the gamma-NMR/ON resonance signal was found at nu = 266.70(5) MHz. Combining this result with the known magnetic moment for this isotope, the magnetic hyperfine field of Ag impurities in an Fe host at low temperature (< 1 K) is found to be vertical bar B-hf(AgFe)vertical bar = 44.709(35) T. A detailed analysis of other relevant data available in the literature yields three more values for this hyperfine field. Averaging all four values yields a new and precise value for the hyperfine field of Ag in Fe; that is, vertical bar B-hf(AgFe)vertical bar = 44.692(30) T. For Ag-104(m) (I-pi = 2(+)), the anisotropy of the beta particles provided the NMR/ON resonance signal at nu = 627.7(4) MHz. Using the new value for the hyperfine field of Ag in Fe, this frequency corresponds to the magnetic moment mu(Ag-104m) = +3.691(3) mu(N), which is significantly more precise than previous results. The magnetic moments of the even-A Ag102 -110 isotopes are discussed in view of the competition between the (pi g(9/2))(7/2+)(-3)(nu d(5/2)nu g(7/2))(5/2+) and the (pi g(9/2))(9/2+)(-3)(nu d(5/2)nu g(7/2))(5/2+) configurations. The magnetic moments of the ground and isomeric states of Ag-104 can be explained by an almost complete mixing of these two configurations.

nucl-ex

Feasibility of photoelectron sources for testing the energy scale stablity of the KATRIN beta-ray spectrometer

Photoabsorption of nuclear gamma-rays in thin metallic convertors was examined with the aim to produce monoenergetic photoelectrons of kinetic energy around 18.6 keV and natural width of about 1 eV. Calculations were carried out for commercial photon sources of 241Am (1.1 GBq) and 119mSn (0.5 GBq) irradiating Co and Ti convertors. Photoelectrons ejected by 241Am gamma- and X-rays from Co convertors of various thickness were measured with two electrostatic spectrometers.

nucl-ex

Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr

A difficult task with many particle detectors focusing on interactions below ~100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly in various locations within the device, a spatially uniform calibration is important. We present a new method for calibration of liquid xenon (LXe) detectors, using the short-lived 83m-Kr. This source has transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses uniformly in all regions of the detector. Even for low source activities, the existence of the two transitions provides a method of identifying the decays that is free of background. We find that at decreasing energies, the LXe light yield increases, while the amount of electric field quenching is diminished. Additionally, we show that if any long-lived radioactive backgrounds are introduced by this method, they will present less than 67E-6 events/kg/day in the next generation of LXe dark matter direct detection searches

astro-ph.IM

Long term stability of the energy of conversion electrons emitted from solid 83Rb/83mKr source

The mono-energetic conversion electrons from the decay of 83mKr represent a unique tool for the energy calibration, energy scale monitoring and systematic studies of the tritium beta spectrum measurement in the neutrino mass experiment KATRIN. For this reason, the long term stability of energy of the 7.5 keV and 17.8 keV conversion electrons populated in the decay of solid 83Rb/83mKr vacuum evaporated sources was examined by means of two electron spectrometers.

physics.ins-det

Distribution of the 83Rb/83mKr activity on vacuum evaporated samples examined with the Timepix position sensitive detector

Properties of vacuum evaporated 83Rb/83mKr sources of low-energy conversion electrons, which are under development for monitoring the energy scale stability of the Karlsruhe Tritium Neutrino experiment KATRIN, were examined by the Timepix pixel detector exhibiting the position resolution of at least 55 microm. No distinct local inhomogeneities in the surface distribution of 83Rb/83mKr were observed. The source diameter derived from the recorded image agrees within 5 % with that expected from evaporation geometry. More precise determination of the actual source diameter is complicated by Compton scattered electrons caused by 83Rb gamma-rays.

nucl-ex