An improved direct limit on the muon electric dipole moment

A limit on the permanent electric dipole moment (EDM) of the positive muon is presented based on data from the Fermilab Muon g-2 Experiment taken between 2019 and 2020. The tracking detectors measure the average vertical decay angle of positrons from muon decays, enabling a search for an interaction between a possible muon EDM $d_μ$ and the lab-frame magnetic field. The result, $d_μ= (-0.35 \pm 0.19_{\mathrm{stat}} \pm 0.34_{\mathrm{sys}}) \times10^{-19}~e\cdot$cm, is consistent with zero and sets a new direct limit on the muon EDM of $|d_μ|<1.10\times10^{-19}~e\cdot$cm at the 95 percent confidence level.

hep-ex↗

Energy, time, and position resolution measurements of an array of large tapered LYSO crystals

We report on the performance of six custom-made tapered LYSO crystals of unprecedented volume, which constitute a sector of the 19 radiation length electromagnetic calorimeter planned for the PIONEER experiment. The longitudinal response uniformity of each crystal was measured using radioactive sources before characterizing the energy and time resolution of the crystals in an array using a 20 to 80 MeV positron beam at the Paul Scherrer Institute. The array demonstrated an energy resolution better than 2 % for energies above 40 MeV and a time resolution better than 130 ps for energies above 30 MeV. The spatial resolution was measured in the central region of the array to be 4.9 mm at 70 MeV, and was extrapolated to 5.4 mm across a 30 mm radius region using Geant4 simulation. The measured properties satisfy the key design parameters of the PIONEER calorimeter for the measurement of rare pion decays.

physics.ins-det↗

Final Report on the Measurement of the Positive Muon Anomalous Magnetic Moment at Fermilab to 127 ppb

This report details the final measurement of the muon magnetic anomaly, $a_μ=(g_μ-2)/2$, by the Muon $g-2$ experiment at Fermi National Accelerator Laboratory (FNAL), using positive muons collected from 2021 to 2023. The value of $a_μ$ is determined from the ratio of the anomalous spin precession frequency to the shielded proton precession frequency in the muon storage ring magnetic field, combined with external constants known at the 22 ppb level. The new dataset, containing over $2.5$ times the statistics of our previous results, yields $a_μ=116\,592\,0710(162)\times 10^{-12}$ (139 ppb), or $a_μ=116\,592\,0705(148)\times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_μ^{\text{Exp}}=116\,592\,0715(145)\times 10^{-12}$ (124 ppb).

hep-ex↗

Measurement of the Positive Muon Anomalous Magnetic Moment to 127 ppb

A new measurement of the magnetic anomaly $a_μ$ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon $g-2$ Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine $a_μ = 116\,592\,0710(162) \times 10^{-12}$ (139 ppb) for the new datasets, and $a_μ = 116\,592\,0705(148) \times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_μ(\text{exp}) =116\,592\,0715(145) \times 10^{-12}$ (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of four.

hep-ex↗

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each $2.5\times 2.5 \times 18$ cm$^3$ crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30 - 100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. As an example of the results, the energy resolution at 70 MeV of 1.52 $\pm$ 0.03% is more than two times better than reported results using previous generation LYSO crystals.

physics.ins-det↗

Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_μ= 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_μ(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_μ$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).

hep-ex↗

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tildeω'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $ω_a$. From the ratio $ω_a / \tildeω'^{}_p$, together with precisely determined external parameters, we determine $a_μ= 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_μ\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_μ(\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.

hep-ex↗

Fundamental Symmetries, Neutrons, and Neutrinos (FSNN): Whitepaper for the 2023 NSAC Long Range Plan

This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-15, 2022 in Chapel Hill, NC, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 275 scientists registered for the meeting. The whitepaper makes a number of explicit recommendations and justifies them in detail.

nucl-ex↗

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

hep-ex↗

Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab

This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.

physics.acc-ph↗

Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment

The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_μ({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the precession frequency. It also presents the averaging of the results from the eleven separate determinations of ω_a, and the systematic uncertainties on the result.

hep-ex↗

The anomalous magnetic moment of the muon in the Standard Model

We review the present status of the Standard Model calculation of the anomalous magnetic moment of the muon. This is performed in a perturbative expansion in the fine-structure constant $α$ and is broken down into pure QED, electroweak, and hadronic contributions. The pure QED contribution is by far the largest and has been evaluated up to and including $\mathcal{O}(α^5)$ with negligible numerical uncertainty. The electroweak contribution is suppressed by $(m_μ/M_W)^2$ and only shows up at the level of the seventh significant digit. It has been evaluated up to two loops and is known to better than one percent. Hadronic contributions are the most difficult to calculate and are responsible for almost all of the theoretical uncertainty. The leading hadronic contribution appears at $\mathcal{O}(α^2)$ and is due to hadronic vacuum polarization, whereas at $\mathcal{O}(α^3)$ the hadronic light-by-light scattering contribution appears. Given the low characteristic scale of this observable, these contributions have to be calculated with nonperturbative methods, in particular, dispersion relations and the lattice approach to QCD. The largest part of this review is dedicated to a detailed account of recent efforts to improve the calculation of these two contributions with either a data-driven, dispersive approach, or a first-principle, lattice-QCD approach. The final result reads $a_μ^\text{SM}=116\,591\,810(43)\times 10^{-11}$ and is smaller than the Brookhaven measurement by 3.7$σ$. The experimental uncertainty will soon be reduced by up to a factor four by the new experiment currently running at Fermilab, and also by the future J-PARC experiment. This and the prospects to further reduce the theoretical uncertainty in the near future-which are also discussed here-make this quantity one of the most promising places to look for evidence of new physics.

hep-ph↗

Performance of the Muon $g-2$ calorimeter and readout systems measured with test beam data

A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.

physics.ins-det↗

The laser-based gain monitoring system of the calorimeters in the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon $g-2$ laser calibration system, showing how the experimental requirements have been met.

physics.ins-det↗

Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications

We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. The performance is documented in a series of bench and beam tests.

physics.ins-det↗

Electron beam test of key elements of the laser-based calibration system for the muon $g$ $-$ $2$ experiment

We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.

physics.ins-det↗

Precision Muon Physics

The muon is playing a unique role in sub-atomic physics. Studies of muon decay both determine the overall strength and establish the chiral structure of weak interactions, as well as setting extraordinary limits on charged-lepton-flavor-violating processes. Measurements of the muon's anomalous magnetic moment offer singular sensitivity to the completeness of the standard model and the predictions of many speculative theories. Spectroscopy of muonium and muonic atoms gives unmatched determinations of fundamental quantities including the magnetic moment ratio $μ_μ/ μ_p$, lepton mass ratio $m_μ / m_e$, and proton charge radius $r_p$. Also, muon capture experiments are exploring elusive features of weak interactions involving nucleons and nuclei. We will review the experimental landscape of contemporary high-precision and high-sensitivity experiments with muons. One focus is the novel methods and ingenious techniques that achieve such precision and sensitivity in recent, present, and planned experiments. Another focus is the uncommonly broad and topical range of questions in atomic, nuclear and particle physics that such experiments explore.

hep-ex↗

Test of candidate light distributors for the muon (g$-$2) laser calibration system

The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability.