Searcharxiv⌕ Search

arXiv subjects

D. Zavazieva

Publications and source records attributed to D. Zavazieva.

5 recordsLinked to original sources

SiPM optical readout of a PICOSEC Micromegas precise timing detector

By combining a Cherenkov radiator with a semi-transparent photocathode and a two-stage Micromegas amplification element, PICOSEC Micromegas detectors have achieved <20 ps charged-particle time resolution with electronic readout of induced signals. Building upon this performance, we describe SiPM-based optical readout as a novel technique for PICOSEC Micromegas detectors. Single-channel detector prototypes based on glass Micromegas technology were read out with an array of SiPMs. To allow operation in a strongly quenched gas mixture, a solid wavelength shifter is integrated in the glass Micromegas to convert UV scintillation to the visible range and maximise scintillation light output. Timing performance of glass Micromegas in electronic and optical readout modes is compared and <150 ps time resolution is achieved by optically read out scintillation light signals. The achievable spatial resolution from centre-of-gravity reconstruction of event positions from the amplitudes of signals on multiple SiPM channels is σ = 1.25 mm. This demonstrates the possibility of dual-readout of PICOSEC glass Micromegas: electronic signals and optical signals. Finally, camera-based optical readout is presented to demonstrate imaging as another avenue for position reconstruction.

physics.ins-det↗

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $σ<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The study includes laboratory measurements of optical and resistive properties, along with beam tests using 150 GeV/$c$ muons to evaluate the time resolution and photoelectron yield for various photocathodes. The best performance was obtained by a 5 nm Cesium Iodide (CsI) photocathode, reaching $σ= 10.9 \pm 0.3$ ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date. Metallic and carbon-based photocathodes, including Titanium (Ti), Boron Carbide (B$_4$C) and Diamond-Like Carbon (DLC), were also tested, with Ti and B$_4$C emerging as the most promising alternatives, achieving $σ\approx 30$ ps with about 5 extracted photoelectrons. These results demonstrate that improved robustness can be achieved while maintaining excellent time resolution, supporting the feasibility of using the PICOSEC Micromegas concept in future experiments.

physics.ins-det↗

Performance of resistive MPGDs with pad readout coupled to VMM3a ASIC

We present a comparative study of three resistive Micro-Pattern Gaseous Detector (MPGD) technologies - Micromegas, RPWELL, and $μ\mathrm{-RWELL}$ - with VMM3a based readout, using relativistic muons and pions. The Micromegas and the RPWELL were operated in $\mathrm{Ar/CO_2/iC_4H_{10}}$ gas mixture, while the $μ\mathrm{-RWELL}$ in $\mathrm{Ar/CO_2/CF_4}$ (greenhouse gas containing mixture). All detectors operated stably exceeding 96% efficiency. The usage of continuous readout enabled studies of detector electrical instabilities in- and off-beam at near breakdown voltages. Each technology has different advantages making it more suitable for various experimental conditions.

physics.ins-det↗

Exploring DHCAL design and performance with Graph Neural Networks

In the context of a gas-sampling Digital Hadronic Calorimeter (DHCAL), we explore the potential of using Graph Neural Networks (GNN) for hadron energy reconstruction and Particle Identification (PID) in future collider experiments. For PID, we achieved classification efficiencies exceeding 50% for neutrons and pions, with notably higher efficiencies for kaons and protons. Protons exhibited the highest efficiency of 77%, followed by neutral kaons. The energy resolution for these hadrons is studied in the energy range of 1 -- 50 GeV, with a further investigation into the resolution as a function of the incoming particle's angle and readout granularity, focusing on charged pions. Compared to traditional analysis methods, our results indicate that improved performance can be achieved even with coarser detector granularity, potentially making future DHCAL systems more cost-effective.

hep-ex↗

Towards a large-area RPWELL detector: design optimization and performance

We present a new design and assembly procedure of a large-area gas-avalanche Resistive-Plate WELL (RPWELL) detector. A $50\times50 ~\mathrm{cm^2}$ prototype was tested in $\mathrm{80 ~GeV/c}$ muon beam at CERN-SPS, presenting improved performances compared to previous ones: MIP detection efficiency over 96\% with 3\% uniformity across the entire detector area, a charge gain of $\mathrm{\approx{7.5 \times 10^3}}$ with a uniformity of 22\%, and discharge probability below $\mathrm{10^{-6}}$ with a few single hotspots attributed to production imperfections. These results pave the way towards further up-scaling detectors of this kind.

physics.ins-det↗