SearcharxivSearch

arXiv subjects

Dai-Hyuk Yu

Publications and source records attributed to Dai-Hyuk Yu.

10 recordsLinked to original sources

A High-frequency Geodetic VLBI Experiment for Optical Clock Comparison

An intercontinental metrological clock comparison between Italy and the Republic of Korea was performed by means of geodetic K-band VLBI observations. The comparison involved the hydrogen masers (H-masers) used at Medicina and Sejong radio telescopes. The same clocks were simultaneously compared by a satellite link and by high-precision optical clocks maintained at the National Metrology Institutes, KRISS in Korea and INRIM in Italy, and delivered to VLBI antennas via optical fiber. The H-masers frequency difference was estimated by extrapolating the clock rate from VLBI data using two geodetic VLBI software. This was subsequently compared with clock differences derived by satellite link and by local optical clocks. Results obtained with different approaches were in agreement at the level of $10^{-15}$ s/s. This pilot study demonstrates that standard high-frequency (K-band) geodetic VLBI campaigns could be a viable approach to conduct intercontinental clock comparisons, now only possible via satellite links. This uncertainty can be reduced thanks to the planned installation of new-generation, broadband, high-frequency receivers on the involved telescopes. K/Q/W-band geodetic observations will allow an improvement of the accuracy of the resulting group delays through broad bandwidth synthesis from 20 to 100 GHz. Furthermore, the Frequency Phase Transfer (FPT) method will also be explored together with the use of PCAL systems installed at the radio telescopes to improve phase stability and thus allow a better estimation of the station clock parameters.

astro-ph.IM

Evaluation of the blackbody radiation shift of an Yb optical lattice clock at KRISS

As optical clocks are improved to reach the frequency uncertainty below the 10$^{-17}$ level, the frequency shift due to the blackbody radiation (BBR) has been one of the major systematic effects hindering further improvement. To evaluate the BBR shift of an Yb optical lattice clock at KRISS, we installed an in-vacuum BBR shield and made radiation thermometry using a black-coated-sphere thermal probe. After we quantitatively measured the conduction loss of the thermal probe and the effects of all the external radiation sources, we determined the temperature at the atom trap site with an uncertainty of 13 mK, which corresponds to an uncertainty of 0.22 mHz in the clock frequency (a fractional frequency of $4.2\times10^{-19}$). The total uncertainty of the BBR shift including the atomic response is $9.5\times10^{-19}$.

physics.atom-ph

Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year

We report a measurement of the absolute frequency of the 1S0-3P0 transition in the 171Yb optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via TAI (International Atomic Time). The determined absolute frequency is 518 295 836 590 863.75(14) Hz with the relative frequency uncertainty of 2.6x10^-16, which agrees well with other reports. This result is expected to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.

physics.atom-ph

Robust frequency stabilization and linewidth narrowing of a laser with large intermittent frequency jumps using an optical cavity and an atomic beam

An experimental method is developed for the robust frequency stabilization using a high-finesse cavity when the laser exhibits large intermittent frequency jumps. This is accomplished by applying an additional slow feedback signal from Doppler-free fluorescence spectroscopy in an atomic beam with increased frequency locking range. As a result, a stable and narrow-linewidth 556 nm laser maintains the frequency lock status for more than a week, and contributes to more accurate evaluation of the Yb optical lattice clock. In addition, the reference optical cavity is supported at vibration-insensitive points without any vibration isolation table, making the laser setup more simple and compact.

physics.optics

Support-Area Dependence of Vibration-Insensitive Optical Cavities

The vibration sensitivities of optical cavities depending on the support-area were investigated both numerically and experimentally. We performed the numerical simulation with two models; one with total constraint over the support area, and the other with only vertical constraint. A support-area-size insensitive optimal support condition could be found by the numerical simulation. The support-area was determined in the experiment by a Viton rubber pad. The vertical, transverse, and longitudinal vibration sensitivities were measured experimentally. The experimental result agreed with the numerical simulation with a sliding model (only vertical constraint).

physics.ins-det

Improved Absolute Frequency Measurement of the 171Yb Optical Lattice Clock at KRISS Relative to the SI Second

We measured the absolute frequency of the $^1S_0$ - $^3P_0$ transition of $^{171}$Yb atoms confined in a one-dimensional optical lattice relative to the SI second. The determined frequency was 518 295 836 590 863.38(57) Hz. The uncertainty was reduced by a factor of 14 compared with our previously reported value in 2013 due to the significant improvements in decreasing the systematic uncertainties. This result is expected to contribute to the determination of a new recommended value for the secondary representations of the second.

physics.atom-ph

Drift-compensated Low-noise Frequency Synthesis Based on a cryoCSO for the KRISS-F1

In this paper we report on the implementation and stability analysis of a drift-compensated frequency synthesizer from a cryogenic sapphire oscillator (CSO) designed for a Cs/Rb atomic fountain clock. The synthesizer has two microwave outputs of 7 GHz and 9 GHz for Rb and Cs atom interrogation, respectively. The short-term stability of these microwave signals, measured using an optical frequency comb locked to an ultra-stable laser, is better than $5\times10^{-15}$ at an averaging time of 1 s. We demonstrate that the short-term stability of the synthesizer is lower than the quantum projection noise limit of the Cs fountain clock, KRISS-F1(Cs) by measuring the short-term stability of the fountain with varying trapped atom number. The stability of the fountain at 1-s averaging time reaches $2.5\times10^{-14}$ at the highest atom number in the experiment when the synthesizer is used as an interrogation oscillator of the fountain. In order to compensate the frequency drift of the CSO, the output frequency of a waveform generator in the synthesis chain is ramped linearly. By doing this, the stability of the synthesizer at an average time of one hour reaches a level of $10^{-16}$ which is measured with the fountain clock.

physics.ins-det

Cancellation of Collisional Frequency Shifts in Optical Lattice Clocks with Rabi Spectroscopy

We analyze both the s- and p-wave collision induced frequency shifts and propose a over-$π$ pulse scheme to cancel the shifts in optical lattice clocks interrogated by a Rabi pulse. The collisional frequency shifts are analytically solved as a function of the pulse area and the inhomogeneity of the Rabi frequencies. Experimentally measured collisional frequency shifts in an Yb optical lattice clock are in good agreement with the analytical calculations. Based on our analysis, the over-$π$ pulse combined with a small inhomogeneity below 0.1 allows a fractional uncertainty on a level of $10^{-18}$ in both Sr and Yb optical lattice clocks by canceling the collisional frequency shift.

physics.atom-ph

Absolute frequency measurement of 1S0 (F = 1/2) - 3P0 (F = 1/2) transition of 171Yb atoms in a one-dimensional optical lattice at KRISS

We measured the absolute frequency of the optical clock transition 1S0 (F = 1/2) - 3P0 (F = 1/2) of 171Yb atoms confined in a one-dimensional optical lattice and it was determined to be 518 295 836 590 863.5(8.1) Hz. The frequency was measured against Terrestrial Time (TT; the SI second on the geoid) by using an optical frequency comb of which the frequency was phase-locked to an H-maser as a flywheel oscillator traceable to TT. The magic wavelength was also measured as 394 798.48(79) GHz. The results are in good agreement with two previous measurements of other institutes within the specified uncertainty of this work.

physics.atom-ph

Optical repumping of triplet $P$-states enhances magneto-optical trapping of ytterbium atoms

Radiative decay from the excited $^1P_1$ state to metastable $^3P_2$ and $^3P_0$ states is expected to limit attainable trapped atomic population in a magneto-optic trap of ytterbium (Yb) atoms. In experiments we have carried out with optical repumping of $^3P_{0,2}$ states to $^3P_1$, we observe enhancement of trapped atoms yield in the excited $^1P_1$ state. The individual decay rate to each metastable state is measured and the results show an excellent agreement with the theoretical values.

physics.atom-ph