Dalton H Bermudez

Publications and source records attributed to Dalton H Bermudez.

3 recordsLinked to original sources

Correlative Symmetric Index: An alternative mathematical evaluation for beam profile symmetry

Background: Current mathematical quantification methods for beam symmetry are highly sensitive to noise, especially in beam profiles with significant variation. Purpose: This study evaluates the accuracy of standard radiotherapy beam symmetry metrics and compares them to a proposed cross-correlation-based metric called the Correlative Symmetric Index (CSI), as well as the Structural Similarity Index (SSIM). We aim to demonstrate that CSI is less susceptible to noise than traditional methods. Methods: Simulated non-symmetric beam profiles with similar left and right areas were analyzed using both standard and proposed symmetry metrics. To test the robustness of each method to noise, a noisy non-symmetric beam profile was also generated. Measured beam profiles at various depths in a water tank were used to compare the performance of each symmetry metric under realistic clinical conditions. Results: In the noisy, non-symmetric case, CSI and SSIM values were 0.387 and 0.5401, respectively. Traditional metrics such as the Point Difference Quotient (PDQ) and area-based symmetry yielded values of 0.312 and 0.400. The percentage change between the non-symmetric (no noise) and non-symmetric (with noise) cases for PDQ, area-based symmetry, SSIM, and CSI were 11.1%, 5.6%, 16.25%, and 1.43%, respectively. For clinically measured symmetric profiles, all metrics produced values above 0.9. Conclusion: The Correlative Symmetric Index (CSI) demonstrates greater robustness to noise than both pointwise and area-based symmetry methods. CSI provides a reliable measure for quantifying beam symmetry, particularly under noisy conditions.

physics.med-ph↗

A new theoretical Lorentzian Apodization function: A Simulations based Comparison with traditional Apodization functions

Standard apodization methods suppress side lobes but increase FWHM, reducing lateral resolution. Grating lobes can interfere with the main lobe, introducing artifacts in ultrasound images. A simple mathematical apodization function is needed to reduce side lobes while decreasing FWHM, thereby improving lateral resolution. The advantage of the new apodization function is that it performs comparably to the Hanning function in suppressing the first grating lobe while also reducing FWHM. This leads to improved lateral resolution and fewer artifacts caused by interference between side lobes and the main beam. Simulations using the new inverse quadratic apodization and no apodization were conducted with a wave pressure model. The new method was implemented using a rectangular function convoluted with the Fourier transform of an inverse quadratic. FWHM and the first side lobe amplitudes were quantified and compared across apodization functions. The inverse quadratic apodization outperformed no apodization in FWHM, with values of 0.906 mm and 1.22 mm, respectively. For first grating lobe suppression, the inverse quadratic and Hanning apodizations yielded -31.47 dB and -31 dB, respectively. Simulated B-mode wire phantom scans showed CNR values of 1.06 (no apodization), 1.32 (Hanning), and 1.66 (inverse quadratic). Corresponding image sharpness values were 7.3398, 6.6009, and 7.0039. The proposed apodization improves FWHM over rectangular and better suppresses the first side lobe than Hanning. Lorentzian apodization at a= 8, a= 15, the method yields superior CNR compared to standard apodizations, with only a slight trade-off in sharpness.

physics.med-ph↗

Assessment of 7T task fMRI value over 3T task fMRI

Ultra-high field 7T fMRI offers notable advantages over 3T fMRI, including higher signal-to-noise and contrast-to-noise ratios, enabling finer spatial and temporal resolution. This study explores the differences in activation maps from Human Connectome Project datasets between 7T and 3T field strengths, focusing on visual identified using the Glasser atlas. Functional tasks for each scanner were designed to include visual stimuli, with data processed uniformly to ensure comparability. Results showed significantly higher beta coefficients for common regions of activation, such as V3A and V3B, in 7T compared to 3T datasets. This suggests that 7T fMRI data more accurately reflect the idealized time course of task-related conditions, likely due to improved sensitivity to blood oxygenation level-dependent (BOLD) signals. However, variations in experimental design and acquisition parameters between scanners complicate the direct comparison of beta coefficients.

physics.med-ph↗