Searcharxiv⌕ Search

arXiv subjects

Dan Nguyen

Publications and source records attributed to Dan Nguyen.

At least 55 records · Page 3Linked to original sources

A deep learning-based framework for segmenting invisible clinical target volumes with estimated uncertainties for post-operative prostate cancer radiotherapy

In post-operative radiotherapy for prostate cancer, the cancerous prostate gland has been surgically removed, so the clinical target volume (CTV) to be irradiated encompasses the microscopic spread of tumor cells, which cannot be visualized in typical clinical images such as computed tomography or magnetic resonance imaging. In current clinical practice, physicians segment CTVs manually based on their relationship with nearby organs and other clinical information, per clinical guidelines. Automating post-operative prostate CTV segmentation with traditional image segmentation methods has been a major challenge. Here, we propose a deep learning model to overcome this problem by segmenting nearby organs first, then using their relationship with the CTV to assist CTV segmentation. The model proposed is trained using labels clinically approved and used for patient treatment, which are subject to relatively large inter-physician variations due to the absence of a visual ground truth. The model achieves an average Dice similarity coefficient (DSC) of 0.87 on a holdout dataset of 50 patients, much better than established methods, such as atlas-based methods (DSC<0.7). The uncertainties associated with automatically segmented CTV contours are also estimated to help physicians inspect and revise the contours, especially in areas with large inter-physician variations. We also use a 4-point grading system to show that the clinical quality of the automatically segmented CTV contours is equal to that of approved clinical contours manually drawn by physicians.

eess.IV↗

Generalizability issues with deep learning models in medicine and their potential solutions: illustrated with Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) image conversion

Generalizability is a concern when applying a deep learning (DL) model trained on one dataset to other datasets. Training a universal model that works anywhere, anytime, for anybody is unrealistic. In this work, we demonstrate the generalizability problem, then explore potential solutions based on transfer learning (TL) by using the cone-beam computed tomography (CBCT) to computed tomography (CT) image conversion task as the testbed. Previous works have converted CBCT to CT-like images. However, all of those works studied only one or two anatomical sites and used images from the same vendor's scanners. Here, we investigated how a model trained for one machine and one anatomical site works on other machines and other sites. We trained a model on CBCT images acquired from one vendor's scanners for head and neck cancer patients and applied it to images from another vendor's scanners and for other disease sites. We found that generalizability could be a significant problem for this particular application when applying a trained DL model to datasets from another vendor's scanners. We then explored three practical solutions based on TL to solve this generalization problem: the target model, which is trained on a target domain from scratch; the combined model, which is trained on both source and target domain datasets from scratch; and the adapted model, which fine-tunes the trained source model to a target domain. We found that when there are sufficient data in the target domain, all three models can achieve good performance. When the target dataset is limited, the adapted model works the best, which indicates that using the fine-tuning strategy to adapt the trained model to an unseen target domain dataset is a viable and easy way to implement DL models in the clinic.

physics.med-ph↗

A reinforcement learning application of guided Monte Carlo Tree Search algorithm for beam orientation selection in radiation therapy

Due to the large combinatorial problem, current beam orientation optimization algorithms for radiotherapy, such as column generation (CG), are typically heuristic or greedy in nature, leading to suboptimal solutions. We propose a reinforcement learning strategy using Monte Carlo Tree Search capable of finding a superior beam orientation set and in less time than CG.We utilized a reinforcement learning structure involving a supervised learning network to guide Monte Carlo tree search (GTS) to explore the decision space of beam orientation selection problem. We have previously trained a deep neural network (DNN) that takes in the patient anatomy, organ weights, and current beams, and then approximates beam fitness values, indicating the next best beam to add. This DNN is used to probabilistically guide the traversal of the branches of the Monte Carlo decision tree to add a new beam to the plan. To test the feasibility of the algorithm, we solved for 5-beam plans, using 13 test prostate cancer patients, different from the 57 training and validation patients originally trained the DNN. To show the strength of GTS to other search methods, performances of three other search methods including a guided search, uniform tree search and random search algorithms are also provided. On average GTS outperforms all other methods, it find a solution better than CG in 237 seconds on average, compared to CG which takes 360 seconds, and outperforms all other methods in finding a solution with lower objective function value in less than 1000 seconds. Using our guided tree search (GTS) method we were able to maintain a similar planning target volume (PTV) coverage within 1% error, and reduce the organ at risk (OAR) mean dose for body, rectum, left and right femoral heads, but a slight increase of 1% in bladder mean dose.

physics.med-ph↗

Improving Proton Dose Calculation Accuracy by Using Deep Learning

Accurate dose calculation is vitally important for proton therapy. Pencil beam (PB) model-based dose calculation is fast but inaccurate due to the approximation when dealing with inhomogeneities. Monte Carlo (MC) dose calculation is the most accurate method, but it is time consuming. We hypothesize that deep learning methods can boost the accuracy of PB dose calculation to the level of MC. In this work, we developed a deep learning model that converts PB to MC doses for different tumor sites. The proposed model is based on our newly developed hierarchically densely connected U-Net (HD U-Net) network, and it uses the PB dose and patient CT image as inputs to generate the MC dose. We used 290 patients (90 with head and neck, 93 with liver, 75 with prostate, and 32 with lung cancer) to train, validate, and test the model. For each tumor site, we performed four numerical experiments to explore various combinations of training datasets. Training the model on data from all tumor sites together and using the dose distribution of each individual beam as input yielded the best performance for all four tumor sites. The average gamma index (1mm/1% criteria) between the converted dose and the MC dose was 92.8%, 92.7%, 89.7% and 99.6% for head and neck, liver, lung, and prostate test patients, respectively. The average time for dose conversion for a single field was less than 4 seconds. In conclusion, our deep learning-based approach can quickly boost the accuracy of proton PB dose distributions to that of MC dose distributions. The trained model can be readily adapted to new datasets for different tumor sites and from different hospitals through transfer learning. This model can be added as a plug-in to the clinical workflow of proton therapy treatment planning to improve the accuracy of proton dose calculation.

physics.med-ph↗

A Fast Deep Learning Approach for Beam Orientation Optimization for Prostate Cancer IMRT Treatments

We propose a fast beam orientation selection method, based on deep neural networks (DNN), capable of developing a plan comparable to those by the state-of-the-art column generation method. The novelty of Our model lies in its supervised learning structure, the DNN architecture, and ability to learn from anatomical features to predict dosimetrically suitable beam orientations without using the dosimetric information from the candidate beams, a time consuming and computationally expensive process. This may save hours of computation. A supervised DNN is trained to mimic the column generation algorithm, which iteratively chooses beam orientations by calculating beam fitness values based on the KKT optimality conditions. The dataset contains 70 prostate cancer patients. The DNN trained over 400 epochs, each with 2500 steps, using the Adam optimizer and a 6-fold cross-validation technique. The average and standard deviation of training, validation, and testing loss functions among the 6-folds were at most 1.44%. The differences in the dose coverage of PTV between plans generated by column generation and by DNN were 0.2%. The average dose differences received by organs at risk were between 1 and 6 percent: bladder had the smallest average difference, then rectum, left and right femoral heads. The dose received by body had an average difference of 0.1%. In the training phase of the proposed method, the model learns the suitable beam orientations based on the anatomical features of patients and omits time intensive calculations of dose influence matrices for all possible candidate beams. Solving the Fluence Map Optimization to get the final treatment plan requires calculating dose influence matrices only for the selected beams. The proposed DNN is a fast beam orientation selection method based that selects beam orientations in seconds and is therefore suitable for clinical routines.

physics.med-ph↗

Incorporating human and learned domain knowledge into training deep neural networks: A differentiable dose volume histogram and adversarial inspired framework for generating Pareto optimal dose distributions in radiation therapy

We propose a novel domain specific loss, which is a differentiable loss function based on the dose volume histogram, and combine it with an adversarial loss for the training of deep neural networks to generate Pareto optimal dose distributions. The mean squared error (MSE) loss, dose volume histogram (DVH) loss, and adversarial (ADV) loss were used to train 4 instances of the neural network model: 1) MSE, 2) MSE+ADV, 3) MSE+DVH, and 4) MSE+DVH+ADV. 70 prostate patients were acquired, and the dose influence arrays were calculated for each patient. 1200 Pareto surface plans per patient were generated by pseudo-randomizing the tradeoff weights (84,000 plans total). We divided the data into 54 training, 6 validation, and 10 testing patients. Each model was trained for 100,000 iterations, with a batch size of 2. The prediction time of each model is 0.052 seconds. Quantitatively, the MSE+DVH+ADV model had the lowest prediction error of 0.038 (conformation), 0.026 (homogeneity), 0.298 (R50), 1.65% (D95), 2.14% (D98), 2.43% (D99). The MSE model had the worst prediction error of 0.134 (conformation), 0.041 (homogeneity), 0.520 (R50), 3.91% (D95), 4.33% (D98), 4.60% (D99). For both the mean dose PTV error and the max dose PTV, Body, Bladder and rectum error, the MSE+DVH+ADV outperformed all other models. All model's predictions have an average mean and max dose error less than 2.8% and 4.2%, respectively. Expert human domain specific knowledge can be the largest driver in the performance improvement, and adversarial learning can be used to further capture nuanced features. The real-time prediction capabilities allow for a physician to quickly navigate the tradeoff space, and produce a dose distribution as a tangible endpoint for the dosimetrist to use for planning. This can considerably reduce the treatment planning time, allowing for clinicians to focus their efforts on challenging cases.

physics.med-ph↗

A Feasibility Study on Deep Learning-Based Radiotherapy Dose Calculation

Purpose: Various dose calculation algorithms are available for radiation therapy for cancer patients. However, these algorithms are faced with the tradeoff between efficiency and accuracy. The fast algorithms are generally less accurate, while the accurate dose engines are often time consuming. In this work, we try to resolve this dilemma by exploring deep learning (DL) for dose calculation. Methods: We developed a new radiotherapy dose calculation engine based on a modified Hierarchically Densely Connected U-net (HD U-net) model and tested its feasibility with prostate intensity-modulated radiation therapy (IMRT) cases. Mapping from an IMRT fluence map domain to a 3D dose domain requires a deep neural network of complicated architecture and a huge training dataset. To solve this problem, we first project the fluence maps to the dose domain using a modified ray-tracing algorithm, and then we use the HD U-net to map the ray-tracing dose distribution into an accurate dose distribution calculated using a collapsed cone convolution/superposition (CS) algorithm. Results: It takes about one second to compute a 3D dose distribution for a typical 7-field prostate IMRT plan, which can be further reduced to achieve real-time dose calculation by optimizing the network. For all eight testing patients, evaluation with Gamma Index and various clinical goals for IMRT optimization shows that the DL dose distributions are clinically identical to the CS dose distributions. Conclusions: We have shown the feasibility of using DL for calculating radiotherapy dose distribution with high accuracy and efficiency.

physics.med-ph↗

Generating Pareto optimal dose distributions for radiation therapy treatment planning

Radiotherapy treatment planning currently requires many trail-and-error iterations between the planner and treatment planning system, as well as between the planner and physician for discussion/consultation. The physician's preferences for a particular patient cannot be easily quantified and precisely conveyed to the planner. In this study we present a real-time volumetric Pareto surface dose generation deep learning neural network that can be used after segmentation by the physician, adding a tangible and quantifiable end-point to portray to the planner. From 70 prostate patients, we first generated 84,000 intensity modulated radiation therapy plans (1,200 plans per patient) sampling the Pareto surface, representing various tradeoffs between the planning target volume (PTV) and the organs-at-risk (OAR), including bladder, rectum, left femur, right femur, and body. We divided the data to 10 test patients and 60 training/validation patients. We then trained a hierarchically densely connected convolutional U-net (HD U-net), to take the PTV and avoidance map representing OARs masks and weights, and predict the optimized plan. The HD U-net is capable of accurately predicting the 3D Pareto optimal dose distributions, with average [mean, max] dose errors of [3.4%, 7.7%](PTV), [1.6%, 5.6%](bladder), [3.7%, 4.2%](rectum), [3.2%, 8.0%](left femur), [2.9%, 7.7%](right femur), and [0.04%, 5.4%](body) of the prescription dose. The PTV dose coverage prediction was also very similar, with errors of 1.3% (D98) and 2.0% (D99). Homogeneity was also similar, differing by 0.06 on average. The neural network can predict the dose within 1.7 seconds. Clinically, the optimization and dose calculation is much slower, taking 5-10 minutes.

physics.med-ph↗

Three-Dimensional Dose Prediction for Lung IMRT Patients with Deep Neural Networks: Robust Learning from Heterogeneous Beam Configurations

The use of neural networks to directly predict three-dimensional dose distributions for automatic planning is becoming popular. However, the existing methods only use patient anatomy as input and assume consistent beam configuration for all patients in the training database. The purpose of this work is to develop a more general model that, in addition to patient anatomy, also considers variable beam configurations, to achieve a more comprehensive automatic planning with a potentially easier clinical implementation, without the need of training specific models for different beam settings.

physics.med-ph↗

MRI-only brain radiotherapy: assessing the dosimetric accuracy of synthetic CT images generated using a deep learning approach

Purpose: This study assessed the dosimetric accuracy of synthetic CT images generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy, using a deep learning approach. Material and Methods: We conducted a study in 77 patients with brain tumors who had undergone both MRI and computed tomography (CT) imaging as part of their simulation for external beam treatment planning. We designed a generative adversarial network (GAN) to generate synthetic CT images from MRI images. We used Mutual Information (MI) as the loss function in the generator to overcome the misalignment between MRI and CT images (unregistered data). The model was trained using all MRI slices with corresponding CT slices from each training subject s MRI/CT pair. Results: The proposed GAN method produced an average mean absolute error (MAE) of 47.2 +- 11.0 HU over 5-fold cross validation. The overall mean Dice similarity coefficient between CT and synthetic CT images was 80% +- 6% in bone for all test data. Though training a GAN model may take several hours, the model only needs to be trained once. Generating a complete synthetic CT volume for each new patient MRI volume using a trained GAN model took only one second. Conclusions: The GAN model we developed produced highly accurate synthetic CT images from conventional, single-sequence MRI images in seconds. Our proposed method has strong potential to perform well in a clinical workflow for MRI-only brain treatment planning.

physics.med-ph↗

Three-Dimensional Radiotherapy Dose Prediction on Head and Neck Cancer Patients with a Hierarchically Densely Connected U-net Deep Learning Architecture

The treatment planning process for patients with head and neck (H&N) cancer is regarded as one of the most complicated due to large target volume, multiple prescription dose levels, and many radiation-sensitive critical structures near the target. Treatment planning for this site requires a high level of human expertise and a tremendous amount of effort to produce personalized high quality plans, taking as long as a week, which deteriorates the chances of tumor control and patient survival. To solve this problem, we propose to investigate a deep learning-based dose prediction model, Hierarchically Densely Connected U-net, based on two highly popular network architectures: U-net and DenseNet. We find that this new architecture is able to accurately and efficiently predict the dose distribution, outperforming the other two models, the Standard U-net and DenseNet, in homogeneity, dose conformity, and dose coverage on the test data. Averaging across all organs at risk, our proposed model is capable of predicting the organ-at-risk max dose within 6.3% and mean dose within 5.1% of the prescription dose on the test data. The other models, the Standard U-net and DenseNet, performed worse, having an averaged organ-at-risk max dose prediction error of 8.2% and 9.3%, respectively, and averaged mean dose prediction error of 6.4% and 6.8%, respectively. In addition, our proposed model used 12 times less trainable parameters than the Standard U-net, and predicted the patient dose 4 times faster than DenseNet.

physics.med-ph↗

Generating Synthesized Computed Tomography (CT) from Cone-Beam Computed Tomography (CBCT) using CycleGAN for Adaptive Radiation Therapy

Cone beam computed tomography (CBCT) images can be used for dose calculation in adaptive radiation therapy (ART). The main challenges are the large artefacts and inaccurate Hounsfield unit (HU) values. Currently, deformed planning CT images are often used for this purpose, although anatomical accuracy might be a concern. Ideally, we would like to convert CBCT images to CT images with artifacts removed or greatly reduced and HU values corrected while keeping the anatomical accuracy. Recently, deep learning has achieved great success in image-to-image translation tasks. It is very difficult to acquire paired CT and CBCT images with exactly matching anatomy for supervised training. To overcome this limitation, we developed and tested a cycle generative adversarial network (CycleGAN) which is an unsupervised learning method and does not require paired training datasets to synthesize CT images from CBCT images. The synthesized CT (sCT) images have been compared with the deformed planning CT (dpCT) showing visual and quantitative similarity with artifacts being removed and HU value errors being reduced from 71.78 HU to 27.98 HU. Dose calculation accuracy using sCT images has been improved over the original CBCT images, with the average Gamma Index passing rate increased from 95.4% to 97.4% for 1 mm/1% criteria. A deformable phantom study has been conducted and demonstrated better anatomical accuracy for sCT over dpCT.

physics.med-ph↗

A feasibility study for predicting optimal radiation therapy dose distributions of prostate cancer patients from patient anatomy using deep learning

With the advancement of treatment modalities in radiation therapy for cancer patients, outcomes have improved, but at the cost of increased treatment plan complexity and planning time. The accurate prediction of dose distributions would alleviate this issue by guiding clinical plan optimization to save time and maintain high quality plans. We have modified a convolutional deep network model, U-net (originally designed for segmentation purposes), for predicting dose from patient image contours of the planning target volume (PTV) and organs at risk (OAR). We show that, as an example, we are able to accurately predict the dose of intensity-modulated radiation therapy (IMRT) for prostate cancer patients, where the average Dice similarity coefficient is 0.91 when comparing the predicted vs. true isodose volumes between 0% and 100% of the prescription dose. The average value of the absolute differences in [max, mean] dose is found to be under 5% of the prescription dose, specifically for each structure is [1.80%, 1.03%](PTV), [1.94%, 4.22%](Bladder), [1.80%, 0.48%](Body), [3.87%, 1.79%](L Femoral Head), [5.07%, 2.55%](R Femoral Head), and [1.26%, 1.62%](Rectum) of the prescription dose. We thus managed to map a desired radiation dose distribution from a patient's PTV and OAR contours. As an additional advantage, relatively little data was used in the techniques and models described in this paper.

physics.med-ph↗

Intelligent Inverse Treatment Planning via Deep Reinforcement Learning, a Proof-of-Principle Study in High Dose-rate Brachytherapy for Cervical Cancer

Inverse treatment planning in radiation therapy is formulated as optimization problems. The objective function and constraints consist of multiple terms designed for different clinical and practical considerations. Weighting factors of these terms are needed to define the optimization problem. While a treatment planning system can solve the optimization problem with given weights, adjusting the weights for high plan quality is performed by human. The weight tuning task is labor intensive, time consuming, and it critically affects the final plan quality. An automatic weight-tuning approach is strongly desired. The weight tuning procedure is essentially a decision making problem. Motivated by the tremendous success in deep learning for decision making with human-level intelligence, we propose a novel framework to tune the weights in a human-like manner. Using treatment planning in high-dose-rate brachytherapy as an example, we develop a weight tuning policy network (WTPN) that observes dose volume histograms of a plan and outputs an action to adjust organ weights, similar to the behaviors of a human planner. We train the WTPN via end-to-end deep reinforcement learning. Experience replay is performed with the epsilon greedy algorithm. Then we apply the trained WTPN to guide treatment planning of testing patient cases. The trained WTPN successfully learns the treatment planning goals to guide the weight tuning process. On average, the quality score of plans generated under the WTPN's guidance is improved by ~8.5% compared to the initial plan with arbitrary weights, and by 10.7% compared to the plans generated by human planners. To our knowledge, this is the first tool to adjust weights for the treatment planning in a human-like fashion based on learnt intelligence. The study demonstrates potential feasibility to develop intelligent treatment planning system via deep reinforcement learning.

physics.med-ph↗

Super-Resolution 1H Magnetic Resonance Spectroscopic Imaging utilizing Deep Learning

Magnetic resonance spectroscopic imaging (SI) is a unique imaging technique that provides biochemical information from in vivo tissues. The 1H spectra acquired from several spatial regions are quantified to yield metabolite concentrations reflective of tissue metabolism. However, since these metabolites are found in tissues at very low concentrations, SI is often acquired with limited spatial resolution. In this work we test the hypothesis that deep learning is able to upscale low resolution SI, together with the T1-weighted (T1w) image, to reconstruct high resolution SI. We report a novel densely connected Unet (D-Unet) architecture capable of producing super-resolution spectroscopic images. The inputs for the D-UNet are the T1w image and the low resolution SI image while the output is the high resolution SI. The results of the D-UNet are compared both qualitatively and quantitatively to simulated and in vivo high resolution SI. It is found that this deep learning approach can produce high quality spectroscopic images and reconstruct entire 1H spectra from low resolution acquisitions, which can greatly advance the current SI workflow.

physics.med-ph↗

Accurate Real Time Localization Tracking in A Clinical Environment using Bluetooth Low Energy and Deep Learning

Deep learning has started to revolutionize several different industries, and the applications of these methods in medicine are now becoming more commonplace. This study focuses on investigating the feasibility of tracking patients and clinical staff wearing Bluetooth Low Energy (BLE) tags in a radiation oncology clinic using artificial neural networks (ANNs) and convolutional neural networks (CNNs). The performance of these networks was compared to relative received signal strength indicator (RSSI) thresholding and triangulation. By utilizing temporal information, a combined CNN+ANN network was capable of correctly identifying the location of the BLE tag with an accuracy of 99.9%. It outperformed a CNN model (accuracy = 94%), a thresholding model employing majority voting (accuracy = 95%), and a triangulation classifier utilizing majority voting (accuracy = 95%). Future studies will seek to deploy this affordable real time location system in hospitals to improve clinical workflow, efficiency, and patient safety.

physics.med-ph↗

Acceleration and Quantitation of Localized Correlated Spectroscopy using Deep Learning: A Pilot Simulation Study

Nuclear magnetic resonance spectroscopy (MRS) allows for the determination of atomic structures and concentrations of different chemicals in a biochemical sample of interest. MRS is used in vivo clinically to aid in the diagnosis of several pathologies that affect metabolic pathways in the body. Typically, this experiment produces a one dimensional (1D) 1H spectrum containing several peaks that are well associated with biochemicals, or metabolites. However, since many of these peaks overlap, distinguishing chemicals with similar atomic structures becomes much more challenging. One technique capable of overcoming this issue is the localized correlated spectroscopy (L-COSY) experiment, which acquires a second spectral dimension and spreads overlapping signal across this second dimension. Unfortunately, the acquisition of a two dimensional (2D) spectroscopy experiment is extremely time consuming. Furthermore, quantitation of a 2D spectrum is more complex. Recently, artificial intelligence has emerged in the field of medicine as a powerful force capable of diagnosing disease, aiding in treatment, and even predicting treatment outcome. In this study, we utilize deep learning to: 1) accelerate the L-COSY experiment and 2) quantify L-COSY spectra. We demonstrate that our deep learning model greatly outperforms compressed sensing based reconstruction of L-COSY spectra at higher acceleration factors. Specifically, at four-fold acceleration, our method has less than 5% normalized mean squared error, whereas compressed sensing yields 20% normalized mean squared error. We also show that at low SNR (25% noise compared to maximum signal), our deep learning model has less than 8% normalized mean squared error for quantitation of L-COSY spectra. These pilot simulation results appear promising and may help improve the efficiency and accuracy of L-COSY experiments in the future.

physics.med-ph↗

Segmentation of the prostate and organs at risk in male pelvic CT images using deep learning

Inter-and intra-observer variation in delineating regions of interest (ROIs) occurs because of differences in expertise level and preferences of the radiation oncologists. We evaluated the accuracy of a segmentation model using the U-Net structure to delineate the prostate, bladder, and rectum in male pelvic CT images. The dataset used for training and testing the model consisted of raw CT scan images of 85 prostate cancer patients. We designed a 2D U-Net model to directly learn a mapping function that converts a 2D CT grayscale image to its corresponding 2D OAR segmented image. Our network contains blocks of convolution 2D layers with variable kernel sizes, channel number, and activation functions. On the left side of the U-Net model, we used three 3x3 convolutions, each followed by a rectified linear unit (ReLu) (activation function), and one max pooling operation. On the right side of the U-Net model, we used a 2x2 transposed convolution and two 3x3 convolution networks followed by a ReLu activation function. The automatic segmentation using the U-Net generated an average dice similarity coefficient (DC) and standard deviation (SD) of the following: DC +- SD (0.88 +- 0.12), (0.95 +- 0.04), and (0.92 +- 0.06) for the prostate, bladder, and rectum, respectively. Furthermore, the mean of average surface Hausdorff distance (ASHD) and SD were 1.2 +- 0.9 mm, 1.08 +- 0.8 mm, and 0.8 +- 0.6 mm for the prostate, bladder, and rectum, respectively. Our proposed method, which employs the U-Net structure, is highly accurate and reproducible for automated ROI segmentation. This provides a foundation to improve automatic delineation of the boundaries between the target and surrounding normal soft tissues on a standard radiation therapy planning CT scan.

physics.med-ph↗