SearcharxivSearch

arXiv subjects

Daniel A. Shaddock

Publications and source records attributed to Daniel A. Shaddock.

14 recordsLinked to original sources

Enhanced Frequency noise suppression for LISA by combining cavity and arm locking control systems

This paper presents a novel method for laser frequency stabilisation in the Laser Interferometer Space Antenna (LISA) mission by locking a laser to two stable length references - the arms of the interferometer and an on-board optical cavity. The two references are digitally fused using carefully designed control systems, attempting minimal or no changes to the baseline LISA mission hardware. The interferometer arm(s) provides the most stable reference available in the LISA science band (0.1 mHz - 1 Hz), while the cavity sensor's wide-band and linear readout enables additional control system gain below and above the LISA band. The main technical issue with this dual sensor approach is the undesirable slow laser frequency pulling which couples into the control system with the imperfect knowledge of the Doppler shift of the light due to relative spacecraft motion along the LISA arm. This paper outlines requirements on the Doppler shift knowledge to maintain the cavity well within the resonance when activating the fused control system. Two Doppler shift estimation methods are presented that use the already on-board measurements, the inter-spacecraft interferometer link (the main science measurement), and the absolute inter-spacecraft laser ranging system. Both methods reach the required precision after a few thousand seconds of measurement integration. The paper demonstrates an approach to initialise and engage the proposed laser stabilization system, starting from free-running laser and ending with the dual sensor frequency control system. The results show that the technique lowers the residual laser frequency noise in the LISA science band by over 3 orders of magnitude, potentially allowing the requirements on Time-Delay-Interferometry (TDI) to be relaxed - possibly to the point where first-generation TDI may be sufficient.

gr-qc

Broadband reduction of quantum radiation pressure noise via squeezed light injection

We present the reduction and manipulation of quantum radiation pressure noise (QRPN) in an optomechanical cavity with the injection of squeezed light. The optomechanical system consists of a high-reflectivity single-crystal microresonator which serves as one mirror of a Fabry-Perot cavity. The experiment is performed at room temperature and is QRPN dominated between 10 kHz and 50 kHz, frequencies relevant to gravitational wave observatories. We observed a reduction of 1.2 dB in the measurement noise floor with the injection of amplitude squeezed light generated from a below-threshold degenerate optical parametric oscillator. This experiment is a crucial step in realizing the reduction of QRPN for future interferometric gravitational wave detectors and improving their sensitivity.

quant-ph

Observation of squeezed light in the 2 $\mathrm{μm}$ region

We present the generation and detection of squeezed light in the 2 $\mathrm{μm}$ wavelength region. This experiment is a crucial step in realising the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically-poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilised 1984 nm thulium fibre laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured $4.0 \pm 0.1$ dB of squeezing and $10.5 \pm 0.5$ dB of anti-squeezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.

physics.ins-det

Control and tuning of a suspended Fabry-Perot cavity using digitally-enhanced heterodyne interferometry

We present the first demonstration of real-time closed-loop control and deterministic tuning of an independently suspended Fabry-Perot optical cavity using digitally-enhanced heterodyne interferometry, realising a peak sensitivity of $\sim$10 pm$/\sqrt{\mathrm{Hz}}$ over the 10-1000 Hz frequency band. The methods presented are readily extensible to multiple coupled cavities. As such, we anticipate that refinements of this technique may find application in future interferometric gravitational-wave detectors.

physics.optics

Thermal noise of gram-scale cantilever flexures

We present measurements of thermal noise in niobium and aluminium flexures. Our measurements cover the audio frequency band from 10Hz to 10kHz, which is of particular relevance to ground-based interferometric gravitational wave detectors, and span up to an order of magnitude above and below the fundamental flexure resonances at 50Hz - 300Hz. Our results are well-explained by a simple model in which both structural and thermoelastic loss play a role. The ability of such a model to explain this interplay is important for investigations of quantum-radiation-pressure noise and the standard quantum limit.

physics.ins-det

Arm-length stabilisation for interferometric gravitational-wave detectors using frequency-doubled auxiliary lasers

Residual motion of the arm cavity mirrors is expected to prove one of the principal impediments to systematic lock acquisition in advanced gravitational-wave interferometers. We present a technique which overcomes this problem by employing auxiliary lasers at twice the fundamental measurement frequency to pre-stabilise the arm cavities' lengths. Applying this approach, we reduce the apparent length noise of a 1.3 m long, independently suspended Fabry-Perot cavity to 30 pm rms and successfully transfer longitudinal control of the system from the auxiliary laser to the measurement laser.

physics.ins-det

Experimental Demonstration of Time-Delay Interferometry for the Laser Interferometer Space Antenna

We report on the first demonstration of time-delay interferometry (TDI) for LISA, the Laser Interferometer Space Antenna. TDI was implemented in a laboratory experiment designed to mimic the noise couplings that will occur in LISA. TDI suppressed laser frequency noise by approximately 10^9 and clock phase noise by 6x10^4, recovering the intrinsic displacement noise floor of our laboratory test bed. This removal of laser frequency noise and clock phase noise in post-processing marks the first experimental validation of the LISA measurement scheme.

astro-ph.IM

An overview of the Laser Interferometer Space Antenna

The Laser Interferometer Space Antenna will detect gravitational waves with frequencies from 0.1 mHz to 1 Hz. This article provides a brief overview of LISA's science goals followed by a tutorial of the LISA measurement concept.

gr-qc

The performance of arm locking in LISA

For the laser interferometer space antenna (LISA) to reach it's design sensitivity, the coupling of the free running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. This paper details an implementation of arm locking, studies orbital effects, the impact of errors in the Doppler knowledge, and noise limits. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultra stable oscillator (clock) noise, spacecraft motion, and shot noise. Studying these issues reveals that although dual arm locking [A. Sutton & D. A Shaddock, Phys. Rev. D 78, 082001 (2008).] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a hybrid sensor, retaining the benefits of common and dual arm locking sensors. We present a detailed design of an arm locking controller and perform an analysis of the expected performance when used with and without laser pre-stabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. We show that the LISA frequency noise goal can be realized with arm locking and Time-Delay Interferometry only, without any form of pre-stabilization.

gr-qc

Data Combinations Accounting for LISA Spacecraft Motion

LISA is an array of three spacecraft in an approximately equilateral triangle configuration which will be used as a low-frequency gravitational wave detector. We present here new generalizations of the Michelson- and Sagnac-type time-delay interferometry data combinations. These combinations cancel laser phase noise in the presence of different up and down propagation delays in each arm of the array, and slowly varying systematic motion of the spacecraft. The gravitational wave sensitivities of these generalized combinations are the same as previously computed for the stationary cases, although the combinations are now more complicated. We introduce a diagrammatic representation to illustrate that these combinations are actually synthesized equal-arm interferometers.

gr-qc

Operating LISA as a Sagnac interferometer

A phase-locking configuration for LISA is proposed that provides a significantly simpler mode of operation. The scheme provides one Sagnac signal readout inherently insensitive to laser frequency noise and optical bench motion for a non-rotating LISA array. This Sagnac output is also insensitive to clock noise, requires no time shifting of data, nor absolute arm length knowledge. As all measurements are made at one spacecraft, neither clock synchronization nor exchange of phase information between spacecraft is required. The phase-locking configuration provides these advantages for only one Sagnac variable yet retains compatibility with the baseline approach for obtaining the other TDI variables. The orbital motion of the LISA constellation is shown to produce a 14 km path length difference between the counter-propagating beams in the Sagnac interferometer. With this length difference a laser frequency noise spectral density of 1 Hz/$\sqrt{\rm Hz}$ would consume the entire optical path noise budget of the Sagnac variables. A significant improvement of laser frequency stability (currently at 30 Hz/$\sqrt{\rm Hz}$) would be needed for full-sensitivity LISA operation in the Sagnac mode. Alternatively, an additional level of time-delay processing could be applied to remove the laser frequency noise. The new time-delayed combinations of the phase measurements are presented.

gr-qc

Implementation of Time-Delay Interferometry for LISA

We discuss the baseline optical configuration for the Laser Interferometer Space Antenna (LISA) mission, in which the lasers are not free-running, but rather one of them is used as the main frequency reference generator (the {\it master}) and the remaining five as {\it slaves}, these being phase-locked to the master (the {\it master-slave configuration}). Under the condition that the frequency fluctuations due to the optical transponders can be made negligible with respect to the secondary LISA noise sources (mainly proof-mass and shot noises), we show that the entire space of interferometric combinations LISA can generate when operated with six independent lasers (the {\it one-way method}) can also be constructed with the {\it master-slave} system design. The corresponding hardware trade-off analysis for these two optical designs is presented, which indicates that the two sets of systems needed for implementing the {\it one-way method}, and the {\it master-slave configuration}, are essentially identical. Either operational mode could therefore be implemented without major implications on the hardware configuration. We then.......

gr-qc

Experimental demonstration of a squeezing enhanced power recycled Michelson interferometer for gravitational wave detection

Interferometric gravitational wave detectors are expected to be limited by shot noise at some frequencies. We experimentally demonstrate that a power recycled Michelson with squeezed light injected into the dark port can overcome this limit. An improvement in the signal-to-noise ratio of 2.3dB is measured and locked stably for long periods of time. The configuration, control and signal readout of our experiment are compatible with current gravitational wave detector designs. We consider the application of our system to long baseline interferometer designs such as LIGO.

quant-ph

Suppression of Classical and Quantum Radiation Pressure Noise via Electro-Optic Feedback

We present theoretical results that demonstrate a new technique to be used to improve the sensitivity of thermal noise measurements: intra-cavity intensity stabilisation. It is demonstrated that electro-optic feedback can be used to reduce intra-cavity intensity fluctuations, and the consequent radiation pressure fluctuations, by a factor of two below the quantum noise limit. We show that this is achievable in the presence of large classical intensity fluctuations on the incident laser beam. The benefits of this scheme are a consequence of the sub-Poissonian intensity statistics of the field inside a feedback loop, and the quantum non-demolition nature of radiation pressure noise as a readout system for the intra-cavity intensity fluctuations.

quant-ph