SearcharxivSearch

arXiv subjects

Daniel Gallagher

Publications and source records attributed to Daniel Gallagher.

2 recordsLinked to original sources

Targeted Syntactic Evaluation of Language Models on Georgian Case Alignment

This paper evaluates the performance of transformer-based language models on split-ergative case alignment in Georgian, a particularly rare system for assigning grammatical cases to mark argument roles. We focus on subject and object marking determined through various permutations of nominative, ergative, and dative noun forms. A treebank-based approach for the generation of minimal pairs using the Grew query language is implemented. We create a dataset of 370 syntactic tests made up of seven tasks containing 50-70 samples each, where three noun forms are tested in any given sample. Five encoder- and two decoder-only models are evaluated with word- and/or sentence-level accuracy metrics. Regardless of the specific syntactic makeup, models performed worst in assigning the ergative case correctly and strongest in assigning the nominative case correctly. Performance correlated with the overall frequency distribution of the three forms (NOM > DAT > ERG). Though data scarcity is a known issue for low-resource languages, we show that the highly specific role of the ergative along with a lack of available training data likely contributes to poor performance on this case. The dataset is made publicly available and the methodology provides an interesting avenue for future syntactic evaluations of languages where benchmarks are limited.

cs.CL

Concentrated Radiative Cooling

A fundamental limit of current radiative cooling systems is that only the top surface facing deep-space can provide the radiative cooling effect, while the bottom surface cannot. Here, we propose and experimentally demonstrate a concept of "concentrated radiative cooling" by nesting a radiative cooling system in a mid-infrared reflective trough, so that the lower surface, which does not contribute to radiative cooling in previous systems, can radiate heat to deep-space via the reflective trough. Field experiments show that the temperature drop of a radiative cooling pipe with the trough is more than double that of the standalone radiative cooling pipe. Furthermore, by integrating the concentrated radiative cooling system as a preconditioner in an air conditioning system, we predict electricity savings of $>75\%$ in Phoenix, AZ, and $>80\%$ in Reno, NV, for a single-story commercial building.

physics.app-ph