SearcharxivSearch

arXiv subjects

Daniel Hengstler

Publications and source records attributed to Daniel Hengstler.

8 recordsLinked to original sources

Fabrication And Characterization Of High-Quality Nb/Al-AlO$_x$/Nb Cross-Type Josephson Tunnel Junctions Utilising CMP-based Planarisation Techniques

Josephson tunnel junctions (JJs) are the fundamental building blocks of today's most advanced superconducting electronic components, such as qubits and superconducting quantum interference devices (SQUIDs). Given the ongoing demand for scalability of these devices on the wafer-scale, it is crucial to control the fabrication process as precisely as possible to ensure uniform quality and reproducibility. Today, window-type JJs are often used in the production of DC SQUIDs and while they are reliable and reproducible, they suffer from alignment inaccuracies caused by photolithography and unavoidable parasitic capacitances, thus limiting the energy sensitivity of DC SQUIDs. These problems can be circumvented by producing JJs with cross-type geometry, which allows for smaller junction areas and eliminates parasitic capacitances. Here we discuss the fabrication of Nb/Al-AlOx/Nb-based cross-type JJs, where the trilayer is embedded in sputter-deposited SiO$_2$ to allow for planarisation of the structures and to ensure the reliable insulation of the sidewalls of the bottom electrode. Instead of lift-off processes that require a lot of time and potentially leave unwanted wings along the edges of microstructures behind that might compromise subsequent layers, we use chemical-mechanical polishing (CMP) for the removal of excess SiO$_2$. This is not only much faster, but produces smooth and uniform surfaces, which in turn effectively improves the reliability of our JJ production process resulting in a high yield of over $90\,\%$ on wafer-scale. In addition, we discuss the influence of fabrication details on the quality and electrical properties of our JJs with different junction areas down to $1\,\mathrm{\mu m} \times 1\,\mathrm{\mu m}$ distributed across the wafer and extract the junction specific quality parameters from their IV-characteristics and their Fraunhofer patterns.

cond-mat.supr-con

Nuclear Charge Radius of $^9$Be from Muonic Atom Spectroscopy Using a Microcalorimeter

The $2p\to1s$ transition energy in muonic $^9$Be was measured using a metallic magnetic calorimeter, resulting in $E_{2p\to 1s}=33\,391.48(34)\,$eV. The result is 30 times more precise than the previous best measurement and enables the extraction of the corresponding nuclear charge radius $r_c($$^9$Be$)=2.5506(51)\,$fm. It is $2.4$ times more precise than the commonly used value based on electron scattering and differs from it by $2.3$ times the combined uncertainties. This measurement represents the first determination of a nuclear charge radius using muonic x-ray spectroscopy with microcalorimeters.

nucl-ex

Improved limit on the effective electron neutrino mass with the ECHo-1k experiment

The effective electron neutrino mass can be determined by analyzing the endpoint region of the $^{163}$Ho electron capture spectrum, provided a measurement with high energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in $^{163}$Ho collaboration, ECHo, presents an analysis of the most precise $^{163}$Ho spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of $B=9.1(1.3)\times 10^{-6}$ /eV/pixel/day was achieved allowing for a reliable analysis of the endpoint region. The derived endpoint energy $Q = 2862(4)$ eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of $Q=2863.2(6)$ eV [1]. The upper limit of the effective electron neutrino mass is improved by almost a factor 2 compared to the lowest current value [2], reaching $m_{\nu_\mathrm{e}} < 15 $ eV/c${^2}$ (90\% credible interval).

hep-ex

Quantum Electrodynamics in Strong Electromagnetic Fields: Substate Resolved K$\alpha$ Transition Energies in Helium-like Uranium

Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U$^{90+}$) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K$\alpha$ transitions in U$^{90+}$. We find good agreement with state-of-the-art bound-state QED calculations for the strong-field regime. Our results do not support any systematic deviation between experiment and theory in helium-like systems, the presence of which was subject of intense debates in recent years.

physics.atom-ph

MMC Array to Study X-ray Transitions in Muonic Atoms

The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We discuss the performance achieved with the maXs-30 detector module to be used. To place the detector close to the target chamber where the muon beam will impact the material under study, we have developed a new dilution refrigerator sidearm. We further discuss the expected efficiency given the transparency of the X-ray windows and the quantum efficiency of the detector. The expected muonic X-ray rate combined with the high resolving power and detection efficiency of the detector suggest that QUARTET will be able to study the de-excitation of light muonic atoms at an unprecedented level, increasing the relative energy resolution by up to a factor of 20 compared to conventional detector techniques.

physics.ins-det

Towards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei

We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.

physics.atom-ph

Measuring Magnetic 1/f Noise in Superconducting Microstructures and the Fluctuation-Dissipation Theorem

The performance of superconducting devices like qubits, SQUIDs, and particle detectors is often limited by finite coherence times and 1/f noise. Various types of slow fluctuators in the Josephson junctions and the passive parts of these superconducting circuits can be the cause, and devices usually suffer from a combination of different noise sources, which are hard to disentangle and therefore hard to eliminate. One contribution is magnetic 1/f noise caused by fluctuating magnetic moments of magnetic impurities or dangling bonds in superconducting inductances, surface oxides, insulating oxide layers, and adsorbates. In an effort to further analyze such sources of noise, we have developed an experimental set-up to measure both the complex impedance of superconducting microstructures, and the overall noise picked up by these structures. This allows for important sanity checks by connecting both quantities via the fluctuation-dissipation theorem. Since these two measurements are sensitive to different types of noise, we are able to identify and quantify individual noise sources. The superconducting inductances under investigation form a Wheatstone-like bridge, read out by two independent cross-correlated dc-SQUID read-out chains. The resulting noise resolution lies beneath the quantum limit of the front-end SQUIDs and lets us measure noise caused by just a few ppm of impurities in close-by materials. We present measurements of the insulating SiO2 layers of our devices, and magnetically doped noble metal layers in the vicinity of the pickup coils at T = 40 mK - 800 mK and f = 1 Hz - 100 kHz.

cond-mat.supr-con

Measurement of the $^{229}$Th isomer energy with a magnetic micro-calorimeter

We present a measurement of the low-energy (0--60$\,$keV) $γ$ ray spectrum produced in the $α$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme determines the $^{229}$Th isomer energy to be $8.10(17)\,$eV, corresponding to 153.1(37)$\,$nm, superseding in precision previous values based on $γ$ spectroscopy, and agreeing with a recent measurement based on internal conversion electrons. We also measure branching ratios of the relevant excited states to be $b_{29}=9.3(6)\%$ and $b_{42}=0.3(3)\%$.

nucl-ex